ECB violations
Marginal Street, Manhattan • Block 00016 • Lot 0140
34 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Mar 24, 2023 | 39514604M | RESOLVE | CLASS - 1 | AT THE TIME OF INSPECTION, THE RIGGER FOREMAN DID NOT PROVIDE OR DISPLAY THE SITE SAFETY LOGBOOK FOR THE JOBSITE AS R... | $625 | $0 | Jun 1, 2023 |
| Mar 24, 2023 | 39514605Y | RESOLVE | CLASS - 1 | AT THE TIME OF INSPECTION, I OBSERVED THAT THE OUTRIGGERS ON EXPO# 1 AND 2 INCLUDING THE TIEBACK DETAILS ARE COMPLETE... | $625 | $0 | Jun 1, 2023 |
| Mar 24, 2023 | 39514606X | RESOLVE | CLASS - 1 | AT THE TIME OF INSPECTION, MR. GREGORIO SANCHEZ AND MR. MARLON CLAVIJO WERE IDENTIFIED BY THE RIGGER FOREMAN AS THE W... | $625 | $0 | Jun 1, 2023 |
| Apr 6, 2019 | 35412526N | RESOLVE | CLASS - 1 | 3301.2;FAILURE TO MAINTAIN SAFE OPERATION DURING CONSTRUCTION.AT THE TIME OF MY INSPECTION TO RESPOND AN INCIDENT OBS... | $1,265 | -$1,265 | Aug 1, 2019 |
| Sep 25, 2018 | 39000441Z | RESOLVE | CLASS - 2 | DEFECTIVE ELECTRICAL WIRING ON 41ST FLOOR MACHINE VROOM, COMPLY WITH CODE | $400 | $0 | Nov 15, 2018 |
| Sep 24, 2018 | 38264570H | RESOLVE | CLASS - 1 | 91X10.FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.SERVICE EQUIPMENT-ELEVATORS PER BC3001.2. & 27-987.DOB RE... | $1,250 | $0 | Oct 11, 2018 |
| Sep 24, 2018 | 38264571J | RESOLVE | CLASS - 1 | 97X10 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE EQUIPMENT ELEVATOR AS PER BC 3001.2 AND 27-987. ... | $0 | $0 | Oct 11, 2018 |
| Feb 5, 2018 | 38261114K | RESOLVE | CLASS - 2 | 67X10,52Q03,05B07. 67X10-REPAIR TWO WAY COMMUNICATION; 52Q03-PROVID EMISSING CABLE GUARD ON MACHINE ROOM; 05B07-PROVI... | $0 | $0 | Mar 22, 2018 |
| Jan 31, 2018 | 38261108Y | RESOLVE | CLASS - 1 | CU05A10,66N10; 59B07,26D07,37D06. 05A07,59N10-CEASE USE ITEMS, DOOR ZONE RESTRICTOR IS MISSING BRACKET RENDERING THE ... | $1,000 | $0 | Mar 22, 2018 |
| Jan 31, 2018 | 38261107M | RESOLVE | CLASS - 1 | CU-05A07,66N10; 59B07,42D06,26I10,52D07,42B09. 05A07;59N10-CEASE USE ITEMS. DOOR ZONE RESTRICTOR IS MISSING BRACKET R... | $1,000 | $0 | Mar 22, 2018 |
| Oct 21, 2016 | 38250102J | RESOLVE | CLASS - 2 | 89H11. MUST REPALCE WORN/SHARP STEP/THREAD. REPLACE ALL WORN STEPS WITH SHARP THREAD. | $0 | $0 | Dec 8, 2016 |
| Jul 15, 2013 | 38223385P | RESOLVE | CLASS - 2 | 52K11 - HOIST ROPES ROUGED, REPLACED. | $500 | $0 | Aug 29, 2013 |
| Mar 27, 2013 | 38223382J | RESOLVE | CLASS - 2 | 100H11- REPLACE WORN COMPENSATING ROPES. | $500 | $0 | May 16, 2013 |
| Nov 4, 2011 | 38219150Z | RESOLVE | CLASS - 2 | 69M07 70O02 91L10. 91L-INAUDIBLE. | $0 | $0 | Dec 22, 2011 |
| Mar 9, 2009 | 34752905H | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY TOTAL OBSTRUCTION OF 2EXITS WERE FOUND IN SOUTHWEST NY EATING AND DRI... | $0 | $0 | Apr 30, 2009 |
| Feb 6, 2009 | 34761709P | RESOLVE | CLASS - 1 | FAIL MAINTAIN BLDG COMPLIANT MANNER:IMPROPER EXIT DOORWAY ARRANGEMENT AS PER B C1014.2;27-361. NOTED: AT THE VESEY ST... | $0 | $0 | Jan 7, 2010 |
| Mar 14, 2007 | 34572050N | RESOLVE | Non-Hazardous | WORK DOSE NOT CONFORM TO APPROVED PLANS. NON-CONFORMING WORK NOTED: A 4TH FL OF PREMISES NORTHWEST CORNER. EXTENSION ... | $130 | $0 | May 10, 2007 |
| Oct 1, 2005 | 38154820Y | RESOLVE | Non-Hazardous | CEASE USE CU79I11/82B10 79/I LEFT SIDE HANDRAIL DAMAGED NEEDS REPLACEMENT. 82/B EMG STOP BUTTON ON UPPER AND LOWER LE... | $500 | $0 | Feb 16, 2006 |
| Oct 1, 2005 | 38154819R | RESOLVE | Non-Hazardous | 82B10 82/B EMG STOP BUTTON ON UPPER AND LOWER LEVEL NEEDS TO BE RELOCATED ALSO NEEDS ALARM ON BUTTON. | $350 | $0 | Feb 16, 2006 |
| Sep 17, 2005 | 38154817N | RESOLVE | Non-Hazardous | 82B10. 82/B EMG STOP BUTTON ON UPPER & LOWER LEVEL NEEDS TO BE RELOCATED ALSO NEEDS ALARM ON BUTTON. | $350 | $0 | Feb 16, 2006 |
| Sep 17, 2005 | 38154818P | RESOLVE | Non-Hazardous | 82B10. 82/B EMG STOP BUTTON ON UPPER & LOWER LEVEL NEEDS TO BE RELOCATED ALSO NEEDS ALARM ON BUTTON. | $350 | $0 | Feb 16, 2006 |
| Jun 4, 2003 | 38136942N | RESOLVE | Non-Hazardous | 59M7 74P7 59/M(CITY I.D. TAG)PROVIDE & SECURE 74/P-PROVIDE ACCESS SO COMPLETE INSPECTION CAN BE PERFORMED BY THIS DEP... | $0 | $0 | Jul 24, 2003 |
| Jun 4, 2003 | 38136945Z | RESOLVE | Non-Hazardous | 59B7 74P7 59/B-PROPERLY SECURE CITY I.D. TAGS 74/P-PROVIDE ACCESS SO A PROPER INSPECTION CAN BE PERFORMED BY THIS DEP... | $0 | $0 | Jul 24, 2003 |
| Jun 4, 2003 | 38136944R | RESOLVE | Non-Hazardous | 59B7 74P7 59/3 PROPERLY SECURE CITY I.D. TAGS 74/P PROVIDE ACCESS SO A COMPLETE INSPECTION CAN BE PERFORMED BY THIS D... | $0 | $0 | Jul 24, 2003 |
| Jun 4, 2003 | 38136943P | RESOLVE | Non-Hazardous | 59M7 74P7 59/M PROVIDE CITY I.D. TAGS & PROPERLY SECURE SAME. 74/P -PROVIDE ACCES SO COMPLETE INSPECTION CAN BE PERFO... | $0 | $0 | Jul 24, 2003 |
| Jun 3, 2003 | 38136940J | RESOLVE | Non-Hazardous | 80M7 59B6 59M7 80M7 80/M PROVIDE CENTER BARRICADES BETWEEN ESCALATORS 59/M FOR CONTROLLER. 80/M PROVIDE REVERSAL STOP... | $180 | $0 | Sep 23, 2003 |
| Jun 3, 2003 | 38136941L | RESOLVE | Non-Hazardous | 59B6 80M7 80/M PROVIDE REHERSAL STOP SWITCH AS PER CODE(805.3H&008.2G)59/B PROPERLY SECURE CITY I.D. TAGS | $0 | $0 | Jul 24, 2003 |
| Jul 25, 2001 | 38117857P | RESOLVE | Non-Hazardous | 72L11/ 69I11/ 72- REPAIR STOP BUTTON 69- REPAIR HANDRAIL | $350 | $0 | Feb 20, 2003 |
| Jul 25, 2001 | 38117858R | RESOLVE | Non-Hazardous | 37A11/ 74##/ 37. PROPERLY WIERE CONTROLLER 74. REPAIR EMBARICATION LIGHT ON 1E20025 | $180 | $0 | Mar 27, 2003 |
| Jan 5, 2000 | 34146955X | RESOLVE | Non-Hazardous | SUPERVISION OR USE OF RIGGING EQUIPMENT WITHOUT A SPECIAL RIGGERS LICENSE. USE OF RIGGING EQUIPMENT WITHOUT PROPER DA... | $1,000 | $0 | Sep 7, 2000 |
| Mar 14, 1998 | 38071605H | RESOLVE | Non-Hazardous | 47L64B64O40O74D74#73# 64-B-11-COMP ROPES ARE CROSSED 64-0-02 CLEAN COMP ROPES SO A PROPER INSPECTION CAN BE MADE 74-D... | $0 | $0 | May 7, 1998 |
| Mar 14, 1998 | 38071604X | RESOLVE | Non-Hazardous | 47L73# 73-#-07-PROVIDE CITY ID TAGS. | $0 | $0 | May 7, 1998 |
| Mar 14, 1998 | 38071243J | RESOLVE | Non-Hazardous | 73U,57O,74B, 73U-PROVIDE CITY ID ON EQUIPMENT 57O-CLEAN PIT 74B-ADJUST COMP SHEAVE CABLES. | $0 | $0 | May 7, 1998 |
| Mar 14, 1998 | 38071606J | RESOLVE | Non-Hazardous | 74B73# 74-B-07-PROVIDE PROPER FLOORING IN OVER HEAD SHEAVE AREA. 73-#-07 PROVIDE CITY ID TAGS. | $0 | $0 | May 7, 1998 |