| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jun 11, 2024 | 39116546J | RESOLVE | CLASS - 2 | PROVIDE TO SECURE THE CAR OPERATING PANEL. HOIST ROPES SHOW SIGNS OF ROUGE. NEED TO REPLACE. COUNTERWEIGHT RUNBY WELL... | $0 | $0 | Aug 15, 2024 |
| Nov 17, 2022 | 39074078P | RESOLVE | CLASS - 2 | CLASS 2: 97.D.6 DEVICE BEING USED TO TRANSPORT PASSENGERS WHILE ALSO CARRYING TOOLS, MATERIALS, AND WORKERS FOR RENNO... | $310 | $0 | Jan 5, 2023 |
| Oct 4, 2022 | 35541084X | RESOLVE | CLASS - 1 | BC 3303.10 TENANT PROTECTION PLAN NOT BEING COMPLIED WITH I OBSERVED WORK BEING PERFORMED THE AFOREMENTIONED JOB NUMB... | $2,500 | $0 | Aug 10, 2023 |
| Oct 4, 2022 | 35541086J | RESOLVE | CLASS - 2 | FAILURE TO POST OR DISTRIBUTE SAFE CONSTRUCTION BILL OF RIGHTS.AT THE TIME OF MY INSPECTION I OBSERVED NO SCBOFR POST... | $1,250 | $0 | Aug 10, 2023 |
| Oct 4, 2022 | 35541085H | RESOLVE | CLASS - 2 | FAILURE TO POST AND DISTRIBUTE NOTICE OF TPP AT THE TIME OF MY INSPECTION I OBSERVED NO NOTICE OF TPP UNDER THE AFORE... | $0 | $0 | Aug 10, 2023 |
| Sep 14, 2022 | 35657123Y | RESOLVE | CLASS - 2 | FAILURE TO POST AND DISTRIBUTE TENANT PROTECTION PLAN.NOTE:AT TIME OF INSPECTION OBSERVED WORK BEING PERFORMED IN NUM... | $1,250 | $0 | May 4, 2023 |
| Sep 14, 2022 | 35657124X | RESOLVE | CLASS - 2 | FAILURE TO POST OR DISTRIBUTE SAFE CONSTRUCTION BILL OF RIGHTS.NOTE:ATTIME OF INSPECTION OBSERVED WORK HAD BEGUN UNDE... | $0 | $0 | May 4, 2023 |
| Sep 14, 2022 | 35657201K | RESOLVE | CLASS - 2 | FAILURE TO POST OR DISTRIBUTE SAFE CONSTRUCTION BILL OF RIGHTS.NOTE:ATTIME OF INSPECTION OBSERVED WORK HAD BEGUN UNDE... | $1,250 | $0 | May 11, 2023 |
| Sep 14, 2022 | 35657122M | RESOLVE | CLASS - 2 | FAILURE TO POST OR DISTRIBUTE SAFE CONSTRUCTION BILL OF RIGHTS.NOTE:ATTIME OF INSPECTION OBSERVED WORK BEING PERFORME... | $1,250 | $0 | May 4, 2023 |
| Sep 14, 2022 | 35657204X | RESOLVE | CLASS - 2 | FAILURE TO POST OR DISTRIBUTE SAFE CONSTRUCTION BILL OF RIGHTS.NOTE:ATTIME OF INSPECTION OBSERVED WORK HAD BEYOND UND... | $0 | $0 | May 11, 2023 |
| Sep 14, 2022 | 35657203Y | RESOLVE | CLASS - 2 | FAILURE TO POST AND DISTRIBUTE TENANT PROTECTION PLAN.NOTE:AT TIME OF INSPECTION OBSERVED WORK HAD BEGUN UNDER THE AF... | $0 | $0 | May 11, 2023 |
| Sep 14, 2022 | 35657202M | RESOLVE | CLASS - 2 | FAILURE TO POST AND DISTRIBUTE TENANT PROTECTION PLAN.NOTE:AT TIME OF INSPECTION OBSERVED WORK HAD BEGUN UNDER THE AF... | $0 | $0 | May 11, 2023 |
| Sep 14, 2022 | 35657200Z | RESOLVE | CLASS - 2 | FAILURE TO POST AND DISTRIBUTE TENANT PROTECTION PLAN.NOTE:AT TIME OF INSPECTION OBSERVED WORK HAD BEGUN UNDER THE AF... | $1,250 | $0 | May 11, 2023 |
| Sep 9, 2022 | 35657117H | RESOLVE | CLASS - 2 | FAILURE TO POST AND DISTRIBUTE TENANT PROTECTION PLAN.NOTE AT TIME OF INSPECTION OBSERVED WORK HAD BEGUN UNDER THE AF... | $1,250 | $0 | May 1, 2023 |
| Sep 9, 2022 | 35657116X | RESOLVE | CLASS - 2 | FAILURE TO POST OF DISTRIBUTE SAFE CONSTRUCTION BILL OF RIGHTS.NOTE ATTIME OF INSPECTION OBSERVED WORK HAD BEGUN UNDE... | $1,250 | $0 | May 1, 2023 |
| Sep 9, 2022 | 35657118J | RESOLVE | CLASS - 1 | 28-201.1 INADEQUATE TENANT PROTECTION PLAN.NOTE AT TIME OF INSPECTION OBSERVED WORK HAD BEGUN UNDER THE AFOREMENTIONE... | $0 | $0 | May 1, 2023 |
| Apr 1, 2022 | 35648081K | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/MANUFACTURERS SPECS NOTED:ATO MY INSP OF ACTIVE FACADE RESTORATION JOBSITE UPON CHECKING SCF MOTO... | $625 | $0 | Sep 29, 2022 |
| Apr 1, 2022 | 35648079L | RESOLVE | CLASS - 1 | WORK DOESNT CONFORM TO APPROVED CD5 NOTED:ATO MY INSP OF ACTIVE FACADERESTORATION JOBSITE WORK ON SUSPENDED SCF I OBS... | $625 | $0 | Sep 29, 2022 |
| Apr 1, 2022 | 35648080Z | RESOLVE | CLASS - 2 | 1041-20K NO CERT OF FITNESS NOTED:ATO MY INSP OF ACTIVE FACADE RESTORATION JOBSITE I OBSERVED 3SUSPENDED SCF IN USE U... | $0 | $0 | Jun 30, 2022 |
| Jan 25, 2022 | 35641929R | RESOLVE | CLASS - 1 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS.AT TIME OF INSPECTION OF AN ACTIV... | $0 | $0 | Sep 22, 2022 |
| Jan 25, 2022 | 35641930Y | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS.AT TIME OF INSPECTION OF AN ACTIV... | $0 | $0 | Apr 28, 2022 |
| Oct 21, 2021 | 35576786K | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE APPROVED/ACCEPTED CONSTRUCTION DOCUMENTS AT JOB SITE AT TIME OF INSPECTION.NOTE:AT TIME OF INSPECT... | $625 | $0 | Jan 27, 2022 |
| Sep 4, 2015 | 32075695K | RESOLVE | CLASS - 2 | B254,50,50A. 50-EXHAUST FAN INSTALLED IN BOILER ROOM W/O MAKE UP AIR 50A-MICRO TURBINE INSTALLED IN BOILER ROOM W/O C... | $500 | $0 | Mar 10, 2016 |
| Sep 4, 2015 | 32075697Y | RESOLVE | CLASS - 2 | B254,24B,50. 50-FRESH AIR FAN TOO BOILER ROOM,MISSING AIR PROVING SWITCH INTERLOCKED WITH BOILER,(NO AIR,BOILER STOPS) | $500 | $0 | Jan 28, 2016 |
| Sep 4, 2015 | 32075693R | RESOLVE | CLASS - 2 | B254,5A,50. 50-STORAGE IN BOILER ROOM. | $500 | $0 | Mar 10, 2016 |
| Sep 4, 2015 | 32075696M | RESOLVE | CLASS - 2 | B254,24B,50,50A. 50-FRESH AIR FAN TOO BOILER ROOM, MISSING AIR PROV ING SWITCH INTERLOCKED W/BOILER, (NO AIR,BOILERS ... | $500 | $0 | Jan 28, 2016 |
| Sep 4, 2015 | 32075694Z | RESOLVE | CLASS - 2 | B254,5A. | $500 | $0 | Mar 10, 2016 |
| Jan 28, 2008 | 38181170P | RESOLVE | Non-Hazardous | 86BB05.MK10. 86BB PERFORM & FILE CURRENT 2YR TEST MK REPAIR RUTED PITSTEEL | $180 | $0 | Jun 11, 2009 |
| Feb 9, 2006 | 38155842J | RESOLVE | Non-Hazardous | 83X10 83X10, RETURN CAR TO SERVICE FOR PROPER INSP. | $350 | $0 | May 4, 2006 |
| Mar 25, 2005 | 34475910J | RESOLVE | Hazardous | NO FLAGPERSON DEFECT NOTED ON NORTH SIDE OF CONSTRUCTION SITE ONE TRUCK WAS OCCUPING 2ND LANE OF STREET WITHOUT FLAG ... | $1,000 | $0 | May 12, 2005 |
| Sep 20, 2004 | 34439775H | RESOLVE | Hazardous | FAILURE TO SAFEGUARD PUBLIC AND PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS DEFECT NOTED AS A RESULT OF THE FAILURE ... | $1,000 | $0 | Nov 4, 2004 |
| Sep 2, 2004 | 34439406M | RESOLVE | Hazardous | RESHORES WITHIN 10 FT. OF FACADE. AS NOTED; RESHORES INSTALLED AT FLRS19, 20, 21 AND 22 WERE NOT SECURED; NOT BANDED ... | $1,250 | $0 | Dec 23, 2004 |