| Jun 12, 2009 | 34792022K | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER-CEILING TILES. 1) ROOM 606 - MISSING TILES. REMEDY: REPAIR AND/OR R... | $0 | $0 | Aug 13, 2009 |
| Jun 12, 2009 | 34792018H | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. 1)MAIN ROOF RAILINGS DO NO EXCEED 31" IN HEIGHT. 2)ATTACHMENTS TO ... | $0 | $0 | Aug 13, 2009 |
| Oct 8, 2008 | 38192376Y | RESOLVE | CLASS - 2 | 56Y13.05J01.12M07.71B07.56Y13 HOIST MACHINE LEAKING SEAL 05B01 ADJUST DOOR CLOSE SO CAR DOOR FULLY CLOSED BEFORE CAR ... | $2,500 | $0 | Nov 20, 2008 |
| Aug 1, 2007 | 34586460N | RESOLVE | Non-Hazardous | 27-334: PROTECTIVE GUARDS. PARAPET RAILING IS APPROXIMATELY 30" HIGH. REMEDY: BRING RAILING UP TO THE HEIGHT OF BUILD... | $0 | $0 | Nov 15, 2007 |
| Aug 1, 2007 | 34586459X | RESOLVE | Non-Hazardous | REISSUE # 34509700Y. FAILURE TO MAINTAIN- EXTERIOR. BASEMENT- GYM- WATER PENETRATION THROUGH EXTERIOR WALL IS COMING ... | $0 | $0 | Nov 15, 2007 |
| Feb 9, 2006 | 34509700Y | RESOLVE | Hazardous | THERE ARE WATER PENETRATION IN EXTERIOR WALL IN GYM (BASEMENT LEVEL) REMEDY: MAINTAIN EXTERIOR BLDG WALL. | $0 | $0 | Apr 6, 2006 |
| Feb 9, 2006 | 34509274K | RESOLVE | Hazardous | THERE ARE VERTICAL CRACKS IN BULKHEAD 10 FLR, ALSO IN GYM 1ST AND 2ND CEILING BEAMS ARE CORRODED AND SAGGING. REMEDY:... | $0 | $0 | Apr 6, 2006 |
| Feb 9, 2005 | 38150978X | RESOLVE | Non-Hazardous | 02B10/55Y13 02-B-10 {BELL DOES NOT RING WHEN STOP SWITCH PULLED} 55-Y-13 {SEAL MAIN MACHINE}. | $2,500 | $0 | Mar 31, 2005 |
| Nov 30, 2004 | 38150304J | RESOLVE | Non-Hazardous | 51K02,55O02,58H11,64Q03,64B11.51-HOIST ROPES HAVE NOISE.55-MACHINE LEAKING OIL.SEAL,LEAK-CLEAN MACHINE AND BED PLATE.... | $2,500 | $0 | Jan 20, 2005 |
| Nov 30, 2004 | 38150307P | RESOLVE | Non-Hazardous | 85U03,83X.85-NO FIVE YEAR TAGS PRESENT.83-ENTIRE DEVICE-MAINLING PULLED FOR SEVERAL YEARS. | $0 | $0 | Feb 9, 2005 |
| Nov 30, 2004 | 38150303H | RESOLVE | Non-Hazardous | 58H11,55O02,38O02,72H01.58-BRAKE SHOES WORN.MACHINE RUNNING BEFORE BRAKE IS FULLY PICKED.55-MACHINE AND BEDPLATE DIRT... | $2,500 | $0 | Jan 20, 2005 |
| Nov 30, 2004 | 38150306N | RESOLVE | Non-Hazardous | 21J01/66P16. 21-CLIPPING DOOR LOCK ROLLERS IN FLIGHT. 66-LINKAGE TO OPEN DOOR LOCK IS MISSING. | $2,500 | $0 | Jan 20, 2005 |
| Nov 30, 2004 | 38150305L | RESOLVE | Non-Hazardous | 17M11/64M11/64Q03/49B11. 17-HOISTING DOOR GIBS MISSING. 64 PIT LIGHT,NO BULB,GUARD.49 GENERATOR BRAKES ARCHING/ | $2,500 | $0 | Jan 20, 2005 |
| Nov 30, 2004 | 38150308R | RESOLVE | Non-Hazardous | 85U05/83X10 85- NO FIVE YEAR TAG PRESENT 83- ENTIRE DEVICE MAINLINE PULLED FOR SEVERAL YEARS. | $0 | -$2,790 | Jan 20, 2005 |
| Mar 17, 2004 | 34431841K | RESOLVE | Non-Hazardous | FAILURE TO POST APPROVED CAPACITY SIGN NOTED: NO CAPACITY SIGN IN GYM AND AUDITORIUM. REMEDY: POST APPROVED CAPACITY ... | $0 | $0 | Jun 17, 2004 |
| Mar 17, 2004 | 34431842M | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN NOTED: MISSING/BROKEN DOOR CHECKS AT 8FL STAIRWAY A 7FL STAIRWAY B(2),A, 6FL STAIRWAY B(2), 5FL S... | $0 | $0 | Jun 17, 2004 |
| Feb 11, 2003 | 34381425Z | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN BUILDING. NOTED; DEFECTIVE DOOR CHECK AT FOURTH FLOOR, STAIR B, EXIT DOOR. REMEDY: MAINTAIN BUILD... | $0 | $0 | Apr 24, 2003 |
| Feb 11, 2003 | 34381424R | RESOLVE | Non-Hazardous | REISSURE! FAILURE TO MAINTAIN BUILDING. NOTED AT FIRST FLOOR AUDITORIUM SEATS, CUSHIONS AND SEAT BACKS ARE SPLIT, TOR... | $0 | $0 | Apr 24, 2003 |
| Feb 11, 2003 | 34381502N | RESOLVE | Non-Hazardous | FAILURE TO POST APPROVED CAPACITY SIGN. NOTED:NO CAPACITY SIGNS AT:EIGHT FLOOR CAFETERIA AND BASEMENT GYM. REMEDY:POS... | $0 | $0 | Apr 24, 2003 |
| Feb 11, 2003 | 34381501L | RESOLVE | Hazardous | EXIT DOOR TOTAL OBSTRCTION. NOTED:AT BASEMENT GYM SOUTHWEST EXIT DOOR DOES NOT OPEN. ALSO NOTED:AT FIRST FLOOR, MAIN ... | $0 | $0 | Apr 24, 2003 |
| Mar 14, 2002 | 34320412K | RESOLVE | Non-Hazardous | FAILURE TO MAITAIN BUILDING. DEFECT NOTED; HAVING INSTALLED A PLSTIC/PLEXI GLASS MATERIAL IN PLACE OF GLASS AT APPROX... | $0 | $0 | May 9, 2002 |
| Mar 14, 2002 | 34320411Z | RESOLVE | Hazardous | FAILURE TO MAINTAIN BUILDING; DEFECT NOTED: BROKEN, SAGGING, LIFTING SIDEWALK ELEVATOR DOORS, CAUSEING A TRIP/FALL HA... | $0 | $0 | May 9, 2002 |
| Mar 14, 2002 | 34320413M | RESOLVE | Non-Hazardous | USE OF ILLEGAL HARDWARE: LOCATION: STAIRWAY "B" EMERGENCY EGRESS DOORS 1ST TO 10TH FLOORS. DESCRIPTION OF HARDWARE: D... | $0 | $0 | May 9, 2002 |
| Apr 20, 2001 | 38115819P | RESOLVE | Non-Hazardous | 75U05-40O02 75 PERFORM 5 YEAR FULL LOAD SAFETY TEST AND FILE. 40 CLEAR GOVERNOR | $2,500 | $0 | Jul 19, 2001 |
| Apr 20, 2001 | 38115821Y | RESOLVE | Non-Hazardous | 75U05-40O02 75 PERFORM 5 YEAR FULL LOAD SAFETY TEST AND FILE. 40-CLEAN GOVERNOR. | $2,500 | $0 | Jul 19, 2001 |
| Apr 20, 2001 | 38115818N | RESOLVE | Non-Hazardous | 75U05-40O02 75-PERFORM 5 YEAR FULL LOAD SAFETY TEST AND FILE 40-CLEAR GOVERNORS | $2,500 | $0 | Jul 19, 2001 |
| Apr 20, 2001 | 38115820M | RESOLVE | Non-Hazardous | 75U05-40O02 75 PERFORM 5 YEAR FULL LOAD SAFETY TEST AND FILE. 40-CLEAR GOVERNOR | $2,500 | $0 | Jul 19, 2001 |
| Sep 19, 2000 | 38107361M | RESOLVE | Non-Hazardous | 73X#,57O02.73-RETURN DEVICE TO SERVICE SO A COMPLETE SAFETY INSPECTIONCAN BE PERFORMED BY THIS DEPARTMENT. | $2,500 | $0 | Nov 9, 2000 |
| Sep 19, 2000 | 38107362Y | RESOLVE | Non-Hazardous | X3X#,57O02.73-RETURN DEVICE TO SERVICE SO A COMPLETE SAFETY INSPECTIONCAR PERFORMED BY THIS DEPT. | $2,500 | $0 | Nov 9, 2000 |
| Sep 19, 2000 | 38107363X | RESOLVE | Non-Hazardous | 09D06,46B07,57O02,15B01.09-SECURE CAR DOOR GIBS.46-PROVIDE PROPER PIT OF CWT CLEARANCE.15-ADJUST 2FL DOOR TO ASIGN PR... | $2,500 | $0 | Nov 9, 2000 |
| Aug 27, 1999 | 34222980J | RESOLVE | Non-Hazardous | NO SHED PERMIT. NOTED: 48 LINEAR FOOT APPROX. OF SHED AT NORTH/EAST CORNER OF BUILDING ERECTED WITHOUT FIRST OBTAININ... | $2,500 | $0 | Oct 14, 1999 |
| Jul 22, 1998 | 34180957Z | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT. WORK NOTED INSTALLED APPROX. 20-0 OF SIDEWALK SHED AT TRINITY PLACE. REMEDY: OBTAIN A PERMIT F... | $2,500 | $0 | Sep 24, 1998 |
| Apr 2, 1998 | 38072764J | RESOLVE | Non-Hazardous | 47H 47-GOVERNOR CABLE WORN | $0 | $0 | May 21, 1998 |
| Apr 2, 1998 | 38072763H | RESOLVE | Non-Hazardous | 47H,47-GOVENER CABLE WORN | $2,500 | $0 | May 21, 1998 |
| Jun 24, 1996 | 34138035N | RESOLVE | Non-Hazardous | INSTALLATION OF MECHANICAL EQUIPMENT WITHOUT FIRST OBTAINING AN EQUIPMENT WORK PERMIT AND EQUIPMENT USE PERMIT ROOF M... | $350 | $0 | Sep 26, 1996 |