| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Mar 16, 2020 | 38272681K | RESOLVE | CLASS - 1 | 42M7 NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC.THI... | $1,280 | $0 | Jul 6, 2020 |
| Mar 16, 2020 | 38272683Y | RESOLVE | CLASS - 1 | 42M7 NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF THE 2014 NYCBC.THIS CONTROLLER FE... | $1,250 | $0 | Dec 11, 2020 |
| Mar 16, 2020 | 38272682M | RESOLVE | CLASS - 1 | 42M7 NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF THE 2014 NYCBC.THIS IS A CONTROLL... | $1,250 | $0 | Dec 11, 2020 |
| Nov 15, 2019 | 37016018P | RESOLVE | CLASS - 2 | 27-929.1 A.C. 27-929-1,FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL... | $0 | $0 | Jun 25, 2020 |
| Jul 20, 2018 | 35346088J | RESOLVE | CLASS - 2 | 37-625 VIOLATION OF CONDITION ON AS OF RIGHT PRIVATELY OWNED SPACE. AS PER NYC ZONING RESOLUTION CHAPTER(7) SECTION 3... | $5,000 | $0 | Nov 15, 2018 |
| Jul 14, 2017 | 35266821N | RESOLVE | CLASS - 2 | BC3307.2.6 MIRRORS AT BLIND SPOTS.AT TIME OF INSPECTION OF 24 STORY ALT3 ANSWERING ABOVE A COMPLAINT.I OBSERVED A BRO... | $0 | $0 | Aug 31, 2017 |
| Mar 15, 2017 | 38253334M | RESOLVE | CLASS - 2 | 97X10 HOIST ELEVATOR IS DOWN DUE TO INCLEMENT WEATHER CONDITIONS. REPAIR AND RESTORE ELEVATOR TO SERVICE. | $250 | $0 | May 4, 2017 |
| Mar 15, 2017 | 38253335Y | RESOLVE | CLASS - 2 | 97X10 HOIST ELEVTOR IS DOWN DUE TO INCLEMENT WEATHER CONDITIONS.REPAIR AND RESTORE ELEVATOR TO SERVICE | $250 | $0 | May 4, 2017 |
| Jan 23, 2017 | 35217411J | RESOLVE | CLASS - 1 | PRESENCE AT SITE.NOTE:AT THE TIME OF MY INSPECTION OF A 32 STORY BLDG UNDER ALTERATION,CONSTRUCTION WORK IN PROGRESS.... | $2,400 | $0 | Dec 7, 2017 |
| Apr 26, 2016 | 35145387Z | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS.AT TIME OF INSPECTION INSTALLING ... | $0 | $0 | Jun 16, 2016 |
| Apr 7, 2016 | 35179066N | RESOLVE | CLASS - 1 | SEC. 3301.6 DESIGN REQUIRED BY CHAPTER 33: FAILURE TO PROVIDE TEMPORARY STRUCTURE DESIGN DWG'S ON THE DATE NOTED ABOV... | $400 | $0 | Aug 12, 2016 |
| Apr 7, 2016 | 35179065L | RESOLVE | CLASS - 1 | SEC. 3301.1.3 FAILURE TO FOLLOW MANUFACTURER SPECIFICATIONS. ON THE DATE NOTED ABOVE I PERFORMED AN INSPECTION OF THE... | $1,600 | $0 | Aug 12, 2016 |
| Apr 7, 2016 | 35179064J | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS: ONTHE DATE NOTED ABOVE I PERFORMED AN INSPECTION ... | $2,400 | $0 | Aug 12, 2016 |
| Apr 7, 2016 | 35179063H | RESOLVE | CLASS - 1 | WORK DOES NOT CONFORM TO APPROVED PLANS &/OR APPROVED AMENDMENTS: FIRESTAIR WELL WALLS ON THE DATE NOTED ABOVE,I PERF... | $0 | $0 | Aug 12, 2016 |
| Apr 7, 2016 | 35179061Y | RESOLVE | CLASS - 1 | SEC. 3317.5;3318.5 MATERIAL/PERSONNEL HOIST. FAILURE TO PROVIDE QUALIFIED HOIST OPERATOR. ON THE DATE NOTED ABOVE,I P... | $0 | $0 | Aug 12, 2016 |
| Apr 7, 2016 | 35179062X | RESOLVE | CLASS - 1 | WORK DOES NOT CONFORM TO APPROVED PLANS &/OR APPROVED AMENDMENTS: ELEVATOR WALLS ON THE DATE NOTED ABOVE I PERFORMED ... | $1,000 | $0 | Aug 12, 2016 |
| Feb 1, 2016 | 35166529H | RESOLVE | CLASS - 1 | SITE SAFETY MANAGER FAILED TO IMMEDIATELY NOTIFY THE DEPT OF CONDITIONS AS REQUIRED.NOTE:@THE TIME OF MY INSP OF A 32... | $2,500 | $0 | May 5, 2016 |
| Nov 12, 2014 | 35039577K | RESOLVE | CLASS - 1 | 250.30(A) GROUNDED SYSTEMS.A SEPARATELY DERIVED AC SYSTEMS THAT IS GROUNDED SHALL COMPLY W/250.30(A)(1)THROUGH (A)(B)... | $1,600 | $0 | Feb 12, 2015 |
| Nov 12, 2014 | 35039576Z | RESOLVE | CLASS - 1 | ELECTRICAL WORK W/OUT A PERMIT.BSMT SERVICE EQUIPMENT:REMOVED OLD SERVICE EQUIPMENT TEMPORARY WIRING,& NEW SERVICE EQ... | $800 | $0 | Feb 12, 2015 |
| Jan 29, 2014 | 38230225L | RESOLVE | CLASS - 1 | 42L10 DUE TO (). ELECTRICAL ISSUES/PROBLEMS WITH TRAVELING CABLES HOISTWAY WIRING AND CONTROLLER WIRING ISSUES. | $1,000 | $0 | Aug 7, 2014 |
| Jan 27, 2010 | 36011588H | RESOLVE | CLASS - 2 | — | $0 | $0 | Jul 22, 2010 |
| Sep 25, 2008 | 36000030P | RESOLVE | CLASS - 1 | FAIL FILE TO COMPLY W/REQUIREMENTS FOR PHOTOLUMINESCENT EXIT MARKING REMEDY: COMPLY WITH REQUIREMENTS OF REFERENCE ST... | $0 | $0 | May 21, 2009 |
| Aug 5, 2003 | 38138822H | RESOLVE | Non-Hazardous | 51, R, 11 44, 0, 02 66, 0, 02 72, F, 02 | $0 | $0 | Sep 25, 2003 |
| Jun 4, 2003 | 38137902N | RESOLVE | Non-Hazardous | 62O02,81U05. (62-O-02) CLEAN PIT. (GARBAGE & WATER) ( 81-U-05) FILE & PERFORM | $180 | $0 | Jul 24, 2003 |
| May 28, 2003 | 38138938J | RESOLVE | Non-Hazardous | 51H11 HOIST ROPES SHOWN EXCESSIVE WEAR. | $0 | $0 | Jul 17, 2003 |
| Apr 15, 2003 | 38137187N | RESOLVE | Non-Hazardous | 48B16/ 50B16/ 62Z09 | $0 | $0 | Jun 5, 2003 |
| Apr 1, 2003 | 38135943K | RESOLVE | Non-Hazardous | 49#15. SHORTER GOVERNOR CABLE | $0 | $0 | May 22, 2003 |
| Mar 28, 2003 | 34384441M | RESOLVE | Non-Hazardous | FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT: PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED... | $0 | $0 | Oct 21, 2003 |
| Feb 26, 2003 | 38133960N | RESOLVE | Non-Hazardous | 48K12,02L11,62Z11,80M07,80L11. 48/K- REPLACE RUSTED AND UNDERSIZES HOIST CABLES. 02/L REPAIR STOP EMG SW. ALARM. 62/2... | $0 | $0 | Apr 17, 2003 |
| Dec 30, 2002 | 38135214K | RESOLVE | Non-Hazardous | 48K12 48/K - HOIST ROPES RUSTED E DAMAGED ROSETTE | $0 | $0 | Feb 13, 2003 |
| Feb 19, 1999 | 38085006N | RESOLVE | Non-Hazardous | #5 50F 07B 57P 50 RLIMINATE BOVN ERRATIVE LEAVING 02 ALARM ON CAR 57 PIT ACCESS FROM LOBBY | $0 | $0 | Apr 15, 1999 |
| Feb 19, 1999 | 38084000H | RESOLVE | Non-Hazardous | 30D 37U 54M 52E 06B 21B 57P 02B 30 CLEAN SMOKE HOLES 37 N Y C TAGS ON CONTROLLERS NOT DOORS 54 REPLACE COVER ON DISCO... | $0 | $0 | Apr 15, 1999 |
| Feb 19, 1999 | 38085001Y | RESOLVE | Non-Hazardous | 30D 57P 02B 30 CLEAR SMOKE HOLES 57 ACCESS TO PUT AT LOBBY 02 PROVIDE ALARM ON CAR AS REQUIERD | $0 | $0 | Apr 15, 1999 |
| Feb 19, 1999 | 38085003H | RESOLVE | Non-Hazardous | 46# 64# 57P 02B 46 REPLACE WORN DEFICTIVE HOIST ROPES 64 REPLACE WORN DEFECTIVE COMP RPPES 57 PROV ACCESS TO PIT AT L... | $0 | $0 | Apr 15, 1999 |
| Feb 19, 1999 | 38085007P | RESOLVE | Hazardous | 02B 07M 03B 37N 73R 02 ALARM NOT ANDIDLE OUTSIDE HOISTWAY 07 INSTALL DOOR OPENING DEVICE WHICH IS ISSING 03 PROVIDE R... | $500 | $0 | Apr 15, 1999 |
| Feb 19, 1999 | 38085008R | RESOLVE | Hazardous | 73R 73 PROVIDE CERTIFICATE OF USE PERMIT ON MAKE APPOINTMENT FOR ACCEPTMENT FOR ACCEPTANCE TEST | $350 | $0 | May 6, 1999 |
| Feb 19, 1999 | 38085005L | RESOLVE | Non-Hazardous | 46# 02B 57P 46 REPAIR WORN DEFECTIVE HOIST ROPES 02 ALARM ON CAR 57 PIT ACCESS FROM LOBBY | $0 | $0 | Apr 15, 1999 |
| Feb 19, 1999 | 38085004J | RESOLVE | Non-Hazardous | 02B 57P 50F 03L 57M 01 ALAERM ON CAR 57 ACCESS TO PIT FROM LOBBY 50F ELIMINATE CAR BOUNCING 03 REPAIR BULGING CAR FLO... | $0 | $0 | Apr 15, 1999 |
| Feb 19, 1999 | 38085002X | RESOLVE | Non-Hazardous | 03L 57P 02B 03 REPAIR BULGNG CAR FL OIL CANING 57 ACCESS TO PIT AT LOBBY 02 ALARM ON CAR | $0 | $0 | Apr 15, 1999 |
| Dec 11, 1998 | 38082764Z | RESOLVE | Non-Hazardous | 02B,14B,11B. PROVIDE ALARM ON CAR TO STOP SW AND ALARM BUTTON, CERTIFICATE IN FRAME OR SIGN, IN CEASE LIGHTING IN CAB. | $0 | $0 | Feb 4, 1999 |
| Dec 11, 1998 | 38082790M | RESOLVE | Non-Hazardous | 02B07,11B07, 03-PROVIDE ALARM ON CAR CONNECTED TO STOP SWITCH AND ALARM BUTTON. 11-INCREASE LIGHTING IN CAB. | $0 | $0 | Feb 25, 1999 |
| Dec 11, 1998 | 38082763R | RESOLVE | Non-Hazardous | 64,02B,14B. REPLACE WORN DEFECTIVE ROPES, PROVIDE ALARM WHICH SOUNDS ON THE CAR CONNECTED TO STOP ALARM BUTTON, PROVI... | $0 | $0 | Feb 4, 1999 |
| Sep 14, 1998 | 34180974K | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN BUILDING. DEFECT IS: FIRE STOPPING IS ALL ELECTRICAL CLOSETS. LOCATION: 1ST FLOOR TO 25TH FLOOR. ... | $0 | $0 | Nov 5, 1998 |
| Jun 29, 1994 | 34108111Z | RESOLVE | Hazardous | FAILURE TO SUBMIT A THIRD ROUND TECHNICAL REPORT: PERIODIC INSPECTIONOF EXTERIOR WALL AND APPRTENANCES AS REQUIRED BY... | $0 | $0 | Aug 10, 1994 |
| Jun 15, 1992 | 38022869K | RESOLVE | Non-Hazardous | 44H,(44)SCORE AND UNDERCUT COMMUTATE. | $100 | $0 | Jul 30, 1992 |
| Apr 24, 1992 | 34063590Z | RESOLVE | Non-Hazardous | STAIR "NO-RE-ENTRY FROM THIS STAIR" SIGNS MISSING STAIRS "A" & "B" ALLFLOORS OCCUPANCY SIDE. FAILURE TO COMPLY WITH V... | $1,000 | $0 | Jun 11, 1992 |
| Mar 14, 1991 | 34048872L | RESOLVE | Non-Hazardous | STAIR "NO RE-ENTRY FROM THIS STAIR" SIGNS MISSING. SIGNS MISSING ON STAIRS "A"&"B",ALL FLOORS OCCUPANCY SIDE REMEDY:I... | $400 | $0 | Apr 25, 1991 |