ECB violations
165-167 William Street, Manhattan • Block 00092 • Lot 0003
44 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jul 14, 2025 | 39153597M | RESOLVE | CLASS - 2 | AS PER ALT-1 JOB # 104802082 WHICH WAS PERMITTED, 4TH FLOOR SHOULD BE 2 APARTMENTS AS LISTED IN C.O. ATOI, OBSERVED A... | $0 | $0 | Sep 18, 2025 |
| Jul 14, 2025 | 39153599X | RESOLVE | CLASS - 2 | AS PER ALT-1 JOB # 104802082 WHICH WAS PERMITTED, 4TH FLOOR SHOULD BE 2 APARTMENTS AS LISTED IN C.O. ATOI, BOTH APART... | $0 | $0 | Nov 20, 2025 |
| Jul 14, 2025 | 39153598Y | RESOLVE | CLASS - 2 | AS PER ALT-1 JOB # 104802082 WHICH WAS PERMITTED, 4TH FLOOR SHOULD BE 2 APARTMENTS AS LISTED IN C.O. ATOI, OBSERVED B... | $0 | $0 | Sep 18, 2025 |
| Oct 11, 2023 | 37025640J | RESOLVE | CLASS - 1 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER IN DOB VIOLATION 315125/042423CER04DE/042823CCER04DE, DATED 4/28/2023... | $0 | $0 | Mar 14, 2024 |
| Jul 12, 2022 | 38274500L | ACTIVE | CLASS - 1 | CEASE USE; 1X10: IN CAR STOP SWITCH BROKEN. REPAIR AND TEST | $1,250 | $0 | Sep 8, 2022 |
| Dec 2, 2020 | 39032807K | RESOLVE | CLASS - 1 | NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS PER 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. REMEDY : INSTAL... | $0 | $0 | Aug 26, 2021 |
| Feb 13, 2020 | 37018529X | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT A REQUIRED CYCLE 8C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALLS & APPURT... | $1,250 | $0 | Feb 18, 2021 |
| Feb 14, 2018 | 38261340Z | RESOLVE | CLASS - 2 | 97R##. REMOVE ELEVATOR W/OUT PERMIT DEVICE# 1F264 FILE, APPLICATION & OBTAIN PERMIT FROM NYC DOB. | $800 | $0 | Jun 7, 2018 |
| Oct 26, 2017 | 35256506Y | RESOLVE | CLASS - 1 | FILED A CERTIFICATE FORM APPLICATION ETC,CONTAINING A MATERIAL FALSE STATEMENTS. NOTED: THE OWNER/REPRESENTATIVE MADE... | $0 | $0 | Dec 14, 2017 |
| Mar 27, 2017 | 38253244Z | RESOLVE | CLASS - 2 | 2M7,2B7,40P16,37P16,70P16. 2M7-2WAY OUTSIDE COMMUNICATION MISSING; 2B7-ALARM BELL NOT WORKING; 40,37,70P16- NO ACCESS... | $0 | $0 | May 11, 2017 |
| Dec 5, 2016 | 38245571X | ACTIVE | CLASS - 2 | 97X10 ENTIRE DEVICE INOPERABLE, REPAIR AND RESTORE TO OPERATION. ELEVATOR HAS BEEN UNDERGOINGAN EBM 593/B ST() 20B. | $530 | $0 | Jan 19, 2017 |
| Mar 7, 2016 | 38241282L | RESOLVE | CLASS - 2 | 02L10,18M07,19D06,37Q03,37D06,37M07,29B10,29E01,39P07,40M07,37L10,70M07. 02-ALARM DEFECTIVE; 18-PROVIDE FIRE GIBBS ON... | $500 | $0 | Apr 21, 2016 |
| Mar 7, 2016 | 38241283N | RESOLVE | CLASS - 2 | 97X10 RESTORE DEVICE TO FULL SERVICE. | $500 | $0 | Apr 21, 2016 |
| Dec 28, 2012 | 35001604N | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN FACADE AND APPURTENANCES. NOTED: AT SOUTHEAST (#4 EXPOSURE) CORNER AT PROPERTY LINE AT APPRX 8 FL... | $0 | $0 | Feb 14, 2013 |
| Oct 4, 2012 | 38220899Z | RESOLVE | CLASS - 2 | 17M07. 2 BRACKETS MISSING ALL FLOORS. | $500 | $0 | Nov 29, 2012 |
| Apr 2, 2012 | 34925765H | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG WALLS & APPURTENANCES. FIRE EGRESS WAS FOUND BLOCKED AT FIRE ESCAPE AT EXPOSURE 3 (WEST/ELEV... | $0 | $0 | May 17, 2012 |
| Feb 9, 2012 | 38220339K | RESOLVE | CLASS - 3 | 40O02,21M07,37O02,37T07,34E09,22H10. 40O- CLEAN MOTOR ROOM, REMOVE OILFROM FLR & BED PLATES. 21M- PROVIDE COVERS INTE... | $0 | $0 | Mar 29, 2012 |
| Feb 9, 2012 | 38220338Z | RESOLVE | CLASS - 3 | 97X10- REPAIR ELEVATOR 1P860 AND RETURN TO SERVICE FOR PROPER DOB INSPECTION. | $0 | $0 | Mar 29, 2012 |
| Oct 27, 2011 | 34752426K | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. OBSTRUCTED AND PARTIAL ACCESS TO STANDPIPE HOSE CONTROL VALV... | $0 | $0 | Feb 9, 2012 |
| Mar 11, 2011 | 34906479N | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/ THE COMM ORDER TO FILE A CERT OF CORRECTION W/ THE DOB RESP FAILED TO COMPLY W/ THE COMM ORDER T... | $0 | $0 | May 19, 2011 |
| Jan 13, 2011 | 34837047N | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER: FAILURE TO COMPLY W/LAW FOR WATER SUPPLY SYSTEM PER PC 602.3. ON I... | $250 | $0 | Apr 11, 2011 |
| Jan 13, 2011 | 34789084Z | RESOLVE | CLASS - 2 | ALTERED BUILDING OCCUPIED W/O A VALID C OF O AS PER 28-118.3.1,28-118.3.2. NOTED ALTERATION #10480208Z ON FILE. CURRE... | $0 | $0 | Mar 3, 2011 |
| Jan 13, 2011 | 34837048P | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER: LACK OF A SYSTEM OFAUTOMATIC SPRINKLERS WHERE REQUIRED PER BC 903.... | $0 | $0 | Apr 11, 2011 |
| Jan 13, 2011 | 34788990X | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLAINT MANNER. AT CELLAR LEVELFOLLOWING DEFECTS NOTED: DEFECTIVE VERTICALLY C... | $0 | $0 | Mar 3, 2011 |
| Jan 13, 2011 | 34788989Z | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING WALLS OR APPURTENANCES. NOTE: APPROX 12' SECTION OF SHEET METAL BOILER CHIMNEY DISLODGED... | $0 | $0 | Apr 11, 2011 |
| Jan 13, 2011 | 34837046L | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER: OBSTRUCTED AND PARTIAL ACCESS TO STANDPIPE (HOSE) CONTROL VALVES A... | $1,000 | $0 | Apr 11, 2011 |
| Jan 11, 2011 | 34789065N | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING WALL OR APPURTENANCES IN CODE-COMPLAINT MANNER: NOTE: AT TIME OF INSPECTION THE UPPER SE... | $0 | $0 | Mar 3, 2011 |
| Sep 22, 2010 | 34837555J | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG WALLS & APPURTENANCES.OBJECTS WERE FOUND BLOCKING FIRE EGRESS @ VARIOUS FLRS @ FIRE ESCAPE @... | $0 | $0 | Nov 10, 2010 |
| Jun 3, 2009 | 38201588H | RESOLVE | CLASS - 3 | 52BB12.21M7 52BB RESHACKLE HOIST ROPES 21M BSMT INTERLOCK COVER MISSING | $500 | $0 | Jul 23, 2009 |
| Jun 3, 2009 | 38201589J | RESOLVE | CLASS - 3 | 52BB12.16P7.RESHACKLE HOIST ROPES 16P 2.3.4.5.6.8.9.FLS NO ACCESS | $500 | $0 | Jul 23, 2009 |
| Oct 8, 2008 | 34701568X | RESOLVE | CLASS - 3 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS/AMENDMENTS CURRENTLY: AT 6FL & 10FL NORTH/WEST PLAN DATED 6/... | $500 | $0 | Nov 20, 2008 |
| Sep 5, 2008 | 34700070Y | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND OR APPROVED AMENDMENTS NOTED THERE IS ONLY APPROX 42" OF... | $500 | $0 | Oct 30, 2008 |
| Jul 10, 2008 | 34689323Z | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTION OPERATION. STOP ALL WORK ON 10 FLOOR EXCEPT TO... | $0 | $0 | Jan 15, 2009 |
| Jun 30, 2008 | 34649013R | RESOLVE | Non-Hazardous | 27-361 EXIT DOOR TOTAL OBSTRUCTION DURING INSPECTION OF EGRESS IT WAS SEEN THAT SOME EGRESS DOORS WERE BLOCK BY CONST... | $480 | $0 | Aug 21, 2008 |
| Apr 29, 2008 | 38182193M | RESOLVE | Non-Hazardous | 38P16.36D06.36I10.66D06.36M07. 36I SKY LIGHT BROKEN GLASS 36M MISSING LIGHT GUARD | $350 | $0 | Jun 19, 2008 |
| Apr 29, 2008 | 38182194Y | RESOLVE | Non-Hazardous | 83X10.38P16.17M07.25D06.12Q03. 17M PROVIDE MEANS OF SECURING 10FL DOORCAN BE PUSHED FROM BOTTOM TO SHORT WAY 25D TOP ... | $350 | $0 | Jun 19, 2008 |
| Mar 31, 2008 | 34587875J | RESOLVE | Hazardous | FAILURE TO MAINTAIN EXT OF BUILDING DEFECTS NOTE METAL TREAD ON FIRE,ESCAPE,ERECTED AT EXPOSURE 3 REAR OF BUILDING MI... | $2,500 | $0 | May 22, 2008 |
| Aug 7, 2007 | 34587114P | RESOLVE | Non-Hazardous | WORK DOES NOT CONFORM TO APPROVED PLAN. NON CONFORMING WORK NOTED: IN THAT CONSTRUCTION OF PARTITION WALLS THRU OUT A... | $130 | $0 | Aug 30, 2007 |
| Jul 2, 2007 | 34490743R | RESOLVE | Non-Hazardous | PLUMBING WORK W/O A PERMIT-HAZARDOUS.UPON INSPECTION WITNESSED PLUMBING & SPRINKLER WORK BEING DONE ON 10TH-7TH-6TH F... | $800 | $0 | Aug 23, 2007 |
| Dec 1, 1994 | 34115895L | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN (1) DEFECTIVE WINDOWS OUT OF LEVEL AND PLUMB CAN--ONT LATCH OR CLOSE PROPERLY. DRAFTY, EAST, NORT... | $175 | $0 | Mar 16, 1995 |
| Dec 1, 1994 | 34115896N | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN AT THE 4TH FLOOR EAST WALL SECTION OF PLASTER WALLUNKEYED FROM BRICK WALL AND CALL, AT HE TOP OF ... | $0 | $0 | Jan 26, 1995 |
| Dec 1, 1994 | 34115894J | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN AT THE 3RD FLOOR (1) ENTRANCE DOOR TO FIRE ESCAPE UNSAFE LOCKING DEVICE AND GLASS PANNELS. VUNERA... | $175 | $0 | Mar 16, 1995 |
| Feb 18, 1992 | 34068004J | RESOLVE | Non-Hazardous | ALTERED BUILDING OCCUPIED WITHOUT A VALID C OF O. ALT 671/87 AS REQUIRED BY ALT 671/87. APARTMENTS OCCUPIED AT 2,5,8,... | $285 | $0 | Jun 25, 1992 |
| Dec 21, 1990 | 34052910P | RESOLVE | Non-Hazardous | FAILURE TO FILE A REPORT OF COMPLIANCE WITH LL16/84 CERTIFYING TO THE INSTALLATION OF REQUIRED FIRE PROTECTION SYSTEM... | $345 | $0 | Aug 1, 1991 |