ECB violations
57-59 Ann Street, Manhattan • Block 00092 • Lot 0010
26 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Apr 18, 2023 | 35716900R | RESOLVE | CLASS - 1 | FAILURE TO NOTIFY DOB.SEVERE CRACKING OF LOAD BEARING PIER E/3.DESPITETHE APPEARANCE OF LARGE CRACKS,EDG DID NOT NOTI... | $12,530 | $12,530 | Jul 14, 2026 |
| Apr 18, 2023 | 35716906H | RESOLVE | CLASS - 1 | REMOVAL OF BRICKS FROM PIER E/3, A LOAD BEARING PIER.PHYSICALLY REMOVED SECTIONS OF MASONRY, ALTERING+PARTIALLY DEMOL... | $12,500 | $12,500 | Sep 24, 2026 |
| Apr 18, 2023 | 35716904Y | RESOLVE | CLASS - 1 | INADEQUATE DESIGN DOCUMENTS/DRAWINGS.DRAWINGS DO NOT INCLUDE SPECIFIC REQ. FOR WHICH STRUCTURAL ELEMENTS WERE TO BE S... | $12,530 | $12,530 | Jul 14, 2026 |
| Apr 18, 2023 | 35716902K | RESOLVE | CLASS - 1 | FAILURE TO NOTIFY THE DOB.EDG DID NOT IDENTIFY CONDITIONS AS UNSAFE.THIS CONDITION CONSTITUTED A MAJOR STRUCTURAL HAZ... | $12,530 | $12,530 | Jul 14, 2026 |
| Apr 18, 2023 | 35716901Z | RESOLVE | CLASS - 1 | FAILURE TO NOTIFY DOB.SEVERE CRACKING OF LOAD BEARING PIER E/3.DESPITE APPEARANCE OF LARGE CRACKS EDG DID NOT NOTIFY ... | $12,500 | $12,500 | Sep 24, 2026 |
| Apr 18, 2023 | 35716903M | RESOLVE | CLASS - 1 | FAILURE TO NOTIFY THE DOB.BRICKS REMOVED FROM LOAD BEARING PIER E/3.EDG DID NOT IDENTIFY CONDITION AS UNSAFE+DID NOT ... | $12,500 | $12,500 | Sep 24, 2026 |
| Apr 18, 2023 | 35716905X | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING STRUCTURE IN A SAFE CONDITION.REMOVAL OF BRICKS FROM PIER E/3,A LOAD BEARING PIER W/O PR... | $6,250 | $6,250 | Sep 24, 2026 |
| Nov 16, 2013 | 35033321J | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER 1)AT CELLAR SOUTH EAST INTERNAL EXIT STAIR MISSING HANDRAIL 2)AT 2N... | $0 | -$250 | Jan 2, 2014 |
| Nov 16, 2013 | 35033322L | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER: IMPROPER EXIT/EXIT ACCESS DOORWAY ARRANGEMENT PER BC 1014.2 & 27-3... | $1,200 | $0 | Jan 2, 2014 |
| Nov 14, 2011 | 34752462H | RESOLVE | CLASS - 3 | SEC. 1016.2, 27-369. FAILURE TO MAINTAIN BLDG IN A CODE COMPLIANT MANNER. PROVIDE CORRIDOR/PASSAGEWAY WIDTH. NOTED: I... | $0 | $0 | Dec 29, 2011 |
| Oct 8, 2009 | 34810261Y | RESOLVE | CLASS - 3 | OCCUPANCY CONTRARY TO THAT ALLOWED BY C/O OR DOB RECORDS. GARAGE IS ARRANGED WITH SPACE ALLOCATED TO BE OCCUPIED AS S... | $400 | $0 | Mar 25, 2010 |
| Oct 8, 2009 | 34810260M | RESOLVE | CLASS - 1 | FAIL TO MAINTAIN INTERIOR BLDG IN CODE COMPLIANT MANNER. BROKEN & DEFECTIVE FIRE STAIRS @ SOUTHWEST SECTION, ROTTEN, ... | $200 | $0 | Mar 25, 2010 |
| Oct 8, 2009 | 34810257L | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. DEFECTS NOTED: AT ANNPARK, LLC GARAGE EXIT PASSAGES AND DOOR USED AS... | $0 | $0 | Mar 25, 2010 |
| Oct 8, 2009 | 34810258N | RESOLVE | CLASS - 1 | WORK WITHOUT A PERMIT! ILLEGAL WORK NOTED-AT BUILDING CELLAR LEVEL FOUND WITH OPENING CREATED AT BRICK MASONRY WALL S... | $1,600 | $0 | Mar 25, 2010 |
| Oct 8, 2009 | 34810259P | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN EXTERIOR BUILDING WALL(S) AND OR APPURTENANCES! NOTED: NUMEROUS CRACKS AT BRICK FACADE BELOW THE ... | $1,000 | $0 | Mar 25, 2010 |
| Jan 8, 2007 | 38163241Y | RESOLVE | Non-Hazardous | 21 I 10/84 B 7/16 M 7/11 L 10/84 M 7/59 X 10/86 M 5/71 K 11/21-DOOR LOCK AT "B"LEVEL DAMAGED;REPAIR.84-CAPACITY PLATE... | $0 | $0 | Mar 8, 2007 |
| Nov 1, 2005 | 34498215J | RESOLVE | Hazardous | FIRE EXIT DOOR TOTAL OBSTRUCTION FIRE EXIT DOOR ON THE SOUTH SIDE ON THE 2ND FLOOR, IS TOTALLY OBSTRUCTED BY VEHICLES... | $0 | $0 | May 11, 2006 |
| Nov 1, 2005 | 34498214H | RESOLVE | Hazardous | FAILURE TO POST THE "CERTIFICATE OF OCCUPANCY" REMEDY: POST THE CERTIFICATE OF OCCUPANCY AT SITE. | $0 | $0 | Feb 2, 2006 |
| Nov 1, 2005 | 34498216L | RESOLVE | Hazardous | FIRE EXIT LIGHTING DEFECTIVE. FIRE EXIT DOOR SIGNS ON THE 2ND 3RD AND ROOF LEVEL ARE DEFECTIVE IN THAT THE SIGNS ARE ... | $0 | $0 | Feb 2, 2006 |
| Nov 25, 2003 | 34408002Y | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN BLDG HAZARDOUS NOTED AT FIRST FLOOR CEILING SLAB CRACKS EXIST BETWEEN GIRBERS SLAP SPALLING CONCR... | $800 | $0 | Feb 26, 2004 |
| Nov 25, 2003 | 34408003X | RESOLVE | Non-Hazardous | EXIT LIGHTING DEFECTIVE NOTE EXIT LIGHTING WITHIN SOUTH STAIRWELL IS NOT WORKING SLUBBS OUT AND ALL EXIT SIGNS AT STA... | $350 | $0 | Feb 26, 2004 |
| Jan 19, 1996 | 38054114Z | RESOLVE | Unknown | 39F,60R,57O.#39-REGROOVE TRACTION SHEIVE.#60-REOALCE CUT BUFFER.#57-CLEAN PIT. | $0 | $0 | Mar 28, 1996 |
| Jan 19, 1996 | 38054115K | RESOLVE | Unknown | 39F,60R,57O.#39-REGROOVE TRACTION SHRIVE #60-REPLACE CUT BUFFER.#57-CLEAN PIT. | $0 | $0 | Mar 28, 1996 |
| Jan 14, 1992 | 38021657Y | RESOLVE | Non-Hazardous | 46K,46H | $0 | $0 | Mar 26, 1992 |
| Apr 23, 1991 | 38010489K | RESOLVE | Hazardous | 15L 18L 40T 37L 47H 15 18 CEASE USE OF 1F263 UNTIL ALL HOISTWAY DOORS & INTERLOCKS ARE IN WORKING ORDER BEFORE RETURN... | $500 | $0 | Jul 18, 1991 |
| Apr 23, 1991 | 38010488Z | RESOLVE | Non-Hazardous | 15L 18L 40T 37L 15 18 CEASE USE OF 1F262 UNTIL ALL HOISTWAY DOORS & INTERLOCKS ARE IN WORKING ORDER BEFORE RETURNING ... | $500 | $0 | Jul 18, 1991 |