ECB violations
104 South Street, Manhattan • Block 00097 • Lot 0010
17 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Nov 21, 2019 | 35463134Y | RESOLVE | CLASS - 2 | 3301.13.13=CONSTRUTCION SUPERINETDENT FAILS TO MAINTAIN AND/OR MAKE JOBSITE LOG BOOK AVAILABLE AT TIME OF INSPECTION ... | $0 | $0 | Jan 30, 2020 |
| Mar 13, 2019 | 35383025P | RESOLVE | CLASS - 2 | 3301.13.13CONST SUPER FAILS TO MAINTAIN AND/OR MAKE JOB SITE LOGS AVAILABLE.@TIME OF INSP ALT1 ACTIVE JOB SITE UPON R... | $0 | $0 | May 9, 2019 |
| Sep 12, 2018 | 35315994J | RESOLVE | CLASS - 2 | CONSTRUCTION SUPERINTENDENT FAILED TO PERFORM DUTIES AS PER CODE.AT THE TIME OF INSPECTION,THE CONSTRUCTION SUPERINTE... | $2,500 | $0 | Dec 20, 2018 |
| Sep 12, 2018 | 35315993H | RESOLVE | CLASS - 1 | WELDERS LICENSE REQUIRES.AT THE ITME OF INSPECTION ON THE 1ST FLOOR A WORKER WAS PERFORMING WELDING ACTIVITIES AT THE... | $0 | $0 | Dec 20, 2018 |
| Sep 12, 2018 | 35315992X | RESOLVE | CLASS - 1 | FAILUE TO INSTITUTE/MAITNAIN SAFETY EQUIPMENT MEASURE SOR TEMPORARY CONSTRUCTION-NO GUARDRAILS.AT THE TIME OF INSPCTI... | $2,500 | $0 | Dec 20, 2018 |
| Jun 13, 2017 | 35275106Z | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION #35245196Y ISSUED ON 04/05/17 AND TO FI... | $0 | $0 | Dec 7, 2017 |
| Apr 5, 2017 | 35245196Y | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD PUBLIC & PROPERTY. NOTED: AT SITE UNDER APP#121183986-ALT-1,FOUND CONSTRUCTION MATERIALS STREWN ... | $10,000 | $0 | Nov 16, 2017 |
| Dec 15, 2016 | 35200234R | RESOLVE | CLASS - 1 | SEC: 3314.6.1. EQUIPMENT (SUPPORTED SCAFFOLD) MUST BE TIED TO A SAFE POINT OF ANCHORAGE. NOTE: @ TIME INSP I OBSERVED... | $1,600 | $0 | Jul 6, 2017 |
| Dec 15, 2016 | 35200235Z | RESOLVE | CLASS - 1 | SEC. 3314.4.4.5 MATERIAL & EQUIPMENT SUSCEPTIBLE TO DISLODGMENT SHALL NOT BE STORED ON SCAFFOLD. NOTE: AT TIME OF INS... | $1,600 | $0 | Apr 6, 2017 |
| Dec 15, 2016 | 35200233P | RESOLVE | CLASS - 1 | SEC: 3314.5.5. SEC: 3314.8.1. GUARDRAIL SYSTEM NOT PROVIDED/PLANKS LOOSE NOT SECURE. NOTE: @ TIME OF INSP I OBSERVED ... | $1,600 | $0 | Jul 6, 2017 |
| Dec 15, 2016 | 35200232N | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE APPROVED CONSTRUCTION DOCUMENTS ON JOB SITE. @ TIME OF INSP. NOTED: @ TIME OF INSP THERE WERE NO A... | $0 | $0 | Apr 6, 2017 |
| Dec 13, 2016 | 35218842X | RESOLVE | CLASS - 1 | SEC. 3309.6 FAILURE TO MONITOR ADJOINING STRUCTURES FOR MOVEMENT IN AL DIRECTIONS DURING EXCAVATION-RELATED ACTIVITY ... | $0 | $0 | Jul 6, 2017 |
| Dec 13, 2016 | 35219004L | RESOLVE | CLASS - 1 | SEC. 3306.7 FAILURE TO PROPERLY SHORE & BRACE A WEAKEND STRUCTURES PRIOR TO FULL OR PARTIAL DEMOLITION. NOTED: AT TIM... | $0 | $0 | Jul 6, 2017 |
| Dec 8, 2014 | 35101042Z | RESOLVE | CLASS - 2 | PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS.NOTED:SIDEWALKSHED ON EXP #2, HAS INOPERABLE LIGHTS, NO LIGHT... | $2,400 | $0 | Jan 22, 2015 |
| Sep 13, 2014 | 35074384H | RESOLVE | CLASS - 2 | SIDEWALK SHED DOES NOT MEET CODE SPECIFICATIONS. NOTE: APPROX 100 L.F.OF SIDEWALK SHED IN PLACE AT FRONT OF BLDG. PER... | $2,400 | $0 | Oct 30, 2014 |
| Jul 9, 2013 | 35025475M | RESOLVE | CLASS - 2 | SIDEWALK SHED DOES NOT MEET CODE SPECIFICATION: APPROX 100 LF OF SIDEWALK IN PLACE AT FRONT OF ABOVE PREMISES, W/NO I... | $2,400 | $0 | Aug 29, 2013 |
| Dec 2, 2008 | 34752606H | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. NOTED: EXP 1 HANGING CORNICES DAMAGED & CORRODED IN DANGER OF ... | $5,000 | $0 | Jan 29, 2009 |