ECB violations
R F Wagner Sr Place, Manhattan • Block 00111 • Lot 0100
97 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Oct 11, 2017 | 35259590J | RESOLVE | CLASS - 1 | PARTIAL STOP WORK ORDER ISSUED OF ALL JOB FILED UNDER APP#122128036 FAILURE TO SAFETY GUARD ALL PERSON & PROPERTY WHI... | $0 | $0 | Mar 8, 2018 |
| Apr 3, 2017 | 35236000Z | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLAINT MANNER. NOTED: AT 1ST FL UPK AREA,LIBRARY ROOM,WATERFALLS DUE TO LEAK IN T... | $0 | $0 | Jun 1, 2017 |
| Apr 3, 2017 | 35236002M | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLAINT MANNER. NOTED: AT UPK AREA,KITCHEN DOR HAS DEFECTIVE IN THE TOP HINGE & NO... | $0 | $0 | Jun 1, 2017 |
| Apr 3, 2017 | 35236001K | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLAINT MANNER. NOTED: AT 1ST FL,UPK AREA,AT CLASS#1 & BALCONY ABOVE GROUND PLAY A... | $0 | $0 | Jun 1, 2017 |
| May 18, 2016 | 35158298J | RESOLVE | CLASS - 2 | TEMPORARY CONSTRUCTION EQUIPMENT ON SITE. EXPIRED PERMIT NOTE:OBSERVEDSIDEWALK SHED IS IN PLACE ALL AROUND THE BUILDI... | $400 | $0 | Jan 9, 2017 |
| May 18, 2016 | 35158297H | RESOLVE | CLASS - 2 | TEMPORARY CONSTRUCTION EQUIPMENT ON SITE. EXPIRED PERMIT. NOTE: OBSERVED SIDEWALK IN PLACE ALL AROUND THE BUILDING. P... | $830 | $0 | Jul 7, 2016 |
| Apr 14, 2016 | 35158129Z | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE SIDEWALK SHED PARAPET SIGN.NOTED: @ TIME OF INSPECTION SIDEWALK SHED @ EXP#1 & EXP#2 MISSING PARAP... | $0 | $0 | Jun 20, 2016 |
| Jan 27, 2016 | 32075334P | RESOLVE | CLASS - 2 | 50A,51,50B. COLUMBIA V.T. HP STEAM BR, 15HPNB147856,GAS FO 2007. 50A-OPERATION OF THE REFERENCED BOILER WAS ELIMINATE... | $250 | $0 | Mar 17, 2016 |
| Oct 29, 2014 | 35039449X | RESOLVE | CLASS - 2 | UNAPPROVED UNSAFE UNSUITABLE ELECTRICAL EQUIPMENT,APPARATUS,MATERIALS,DEVICES,APPLIANCES OR WIRING IN USE. CTOWN SUPE... | $830 | $0 | Jan 8, 2015 |
| Sep 4, 2013 | 35030408Z | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER: NOTED: IN APT #17J AT PERIMETER (WALL) AT WEST SIDE, IN LIVING ROO... | $0 | $0 | Nov 14, 2013 |
| Dec 3, 2012 | 34990500N | RESOLVE | CLASS - 2 | EXPIRED CD-5#SR12-2058 ON 11/30/12 FOR MATERIAL HOIST FOR ROOF OF MASONRY WORKS.NOTED: MATERIAL HOIST INSTALLED ON TH... | $2,500 | $0 | Jan 28, 2016 |
| May 11, 2012 | 34882169Y | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE APPROVED PLANS AT JOB SITE AT TIME OF INSPECTION. NO PLANS AVAILABLE FOR ALT II JOB #120994674. RE... | $0 | $0 | Jul 5, 2012 |
| Dec 21, 2009 | 32067780P | RESOLVE | CLASS - 3 | 36,38,50A,B,C. COLUMBIA VT BOILER,15HP,NB147856,COS DF,2007.36-BOILER NOT REGISTERED.INSTALLED ON BL WORKSITE PERMIT ... | $0 | $0 | Feb 11, 2010 |
| Dec 15, 2009 | 38207904H | RESOLVE | CLASS - 2 | 8V1.8V1 AJUST LEVALING ON ALL FLS WERE NEEDED | $0 | $0 | Feb 4, 2010 |
| Oct 23, 2009 | 36009824H | RESOLVE | CLASS - 2 | FAILURE TO FILE AN AMENDED SIXTH ROUND REPORT ACCEPTABLE TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESC... | $0 | $0 | Feb 4, 2010 |
| May 22, 2009 | 36009085N | RESOLVE | CLASS - 2 | FAILURE TO FILE AN AMENDED 6TH ROUND REPORT ACCEPTABLE TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITITIONS DESC... | $0 | $0 | Jul 23, 2009 |
| Mar 17, 2009 | 38199275R | RESOLVE | CLASS - 2 | 20I10.44H10.52H11.53H11.20I10 REPAIR DAMAGED VISION PANEL 6 FL 44H10 REPAIR WORN TRACTION SHEAVE 52H11 REPLACE WORN H... | $0 | $0 | May 7, 2009 |
| Feb 19, 2009 | 34744113J | RESOLVE | CLASS - 2 | LOCAL LAW REPORT FILED AS "UNSAFE" BY ARCHITECT/ENGINEER; NO AMENDED REPORT WAS FILED. "UNSAFE CONDITIONS" REQUIRES S... | $0 | $0 | Apr 16, 2009 |
| Feb 19, 2009 | 34744112H | RESOLVE | CLASS - 2 | LOCAL LAW REPORT FILED AS "UNSAFE" BY ARCHITECT/ENGINEER; NO AMENDED REPORT WAS FILED. "UNSAFE CONDITIONS" REQUIRES S... | $0 | $0 | Apr 16, 2009 |
| Feb 17, 2009 | 34744104H | RESOLVE | CLASS - 2 | LOCAL LAW REPORT FILED AS "UNSAFE" BY ARCHITECT/ENGINEER. NO AMENDED REPORT WAS FILED. "UNSAFE CONDITIONS" REQUIRES S... | $0 | $0 | Apr 9, 2009 |
| Feb 17, 2009 | 34744103X | RESOLVE | CLASS - 2 | LOCAL LAW REPORT FILED AS "UNSAFE" BY ARCHITECT/ENGINEER. NO AMENDED REPORT WAS FILED. "UNSAFE CONDITIONS" REQUIRES S... | $0 | $0 | Apr 9, 2009 |
| Nov 8, 2008 | 34720775M | RESOLVE | CLASS - 2 | WORK W/O PERMIT: EXPIRED PERMIT. NOTED: PERMIT EXPIRED FOR SIDEWALK SHED ON: 9.17.08. REMEDY: RENEW PERMIT. | $800 | $0 | Mar 25, 2010 |
| Nov 8, 2008 | 34720649L | RESOLVE | CLASS - 2 | WORK W/O PERMIT: EXPIRED PERMIT. NOTED: ERECTED SHED ON BACK OF THE BLDG HAS EXPIRED PERMIT: (9.17.08) REMEDY: RENEW ... | $800 | $0 | Mar 25, 2010 |
| Nov 7, 2008 | 36000566N | RESOLVE | CLASS - 2 | FAILURE TO FILE AN AMENDED 6TH ROUND REPORT ACCEPTABLE TO THIS DEPARTMENT INDICATING CORRECTION OF UNSAFE CONDITIONS ... | $0 | $0 | Dec 18, 2008 |
| Nov 7, 2008 | 36000570X | RESOLVE | CLASS - 2 | FAILURE TO FILE AN AMENDED 6TH ROUND REPORT ACCEPTABLE TO THIS DEPARTMENT INDICATING CORRECTION OF UNSAFE CONDITIONS ... | $0 | $0 | Dec 18, 2008 |
| Nov 7, 2008 | 36000569Z | RESOLVE | CLASS - 2 | FAILURE TO FILE AN AMENDED 6TH ROUND REPORT ACCEPTABLE TO THIS DEPARTMENT INDICATING CORRECTION OF UNSAFE CONDITIONS ... | $0 | $0 | Dec 18, 2008 |
| Nov 7, 2008 | 36000568R | RESOLVE | CLASS - 2 | FAILURE TO FILE AN AMENDED 6TH ROUND REPORT ACCEPTABLE TO THIS DEPARTMENT INDICATING CORRECTION OF UNSAFE CONDITIONS ... | $0 | $0 | Dec 18, 2008 |
| Nov 7, 2008 | 36000567P | RESOLVE | CLASS - 2 | FAILURE TO FILE AN AMENDED 6TH ROUND REPORT ACCEPTABLE TO THIS DEPARTMENT INDICATING CORRECTION OF UNSAFE CONDITIONS ... | $0 | $0 | Dec 18, 2008 |
| Oct 22, 2007 | 38178885L | RESOLVE | Non-Hazardous | 34D06,66O02. | $0 | $0 | Dec 13, 2007 |
| Oct 22, 2007 | 38178887P | RESOLVE | Non-Hazardous | 17M07,28M07,66O02. 17 5TH FL BRACKET AND GIB ASSEMBLY LOBBY DOOR GIBS WORN 28 DOOR OPERATOR COVER MISSING. | $0 | $0 | Dec 13, 2007 |
| Oct 22, 2007 | 38178888R | RESOLVE | Non-Hazardous | 10H10,17H10,38O02,66O02. 17 LOBBY DOOR GIBS. | $0 | $0 | Dec 13, 2007 |
| Oct 22, 2007 | 38178886N | RESOLVE | Non-Hazardous | 38O02,17M07,02L10,28M07,66O02. 17 MISSING GIB ON 15,13,9,8,5, 4TH FLS, LOOSE GIB ON 13TH AND LOBBY DOORS. 02 REPAIR F... | $0 | $0 | Dec 13, 2007 |
| May 19, 2006 | 34549787M | RESOLVE | Non-Hazardous | FAILURE TO SUBMIT A 5TH ROUND TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS:PERIODIC INSP. OF EXT. WALLS & APPURTE... | $0 | $0 | Jun 29, 2006 |
| Mar 17, 2006 | 32049900L | ACTIVE | Non-Hazardous | 18AB,50 FULTON V.T. BOILER, 10HP, NB 58413, GAS, 1989. 50- IMPROPER ARRANGEMENT OF THE BLOWDOWN VALVES. INSTALL A SCR... | $180 | $0 | Jun 8, 2006 |
| Dec 14, 2005 | 38164026X | RESOLVE | Non-Hazardous | 10H11/66O02. 10- CHANGE WORN CAR DOOR GIBS. 66- CLEAN PIT. | $0 | $0 | Jan 26, 2006 |
| Dec 14, 2005 | 38164025Y | RESOLVE | Non-Hazardous | 05I11/51B14/60O02. 05- CHANGE CAR DOOR VISION PANEL. 51- SHORTEN HOISTROPES. 66- CLEAN PIT | $0 | $0 | Jan 26, 2006 |
| Nov 18, 2005 | 34548687K | RESOLVE | Non-Hazardous | FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS: PERIODIC INSPECTION OF EXTERIOR ... | $0 | $0 | Dec 15, 2005 |
| May 12, 2004 | 38147383J | RESOLVE | Non-Hazardous | 66O02. 66-ELEVATOR PIT FOR DEVICE NUMBER 1P22404 IS DIRTY/ACCUMULATED PAPER AND OTHER DEBRIS | $0 | $0 | Jul 1, 2004 |
| May 12, 2004 | 38147384L | RESOLVE | Non-Hazardous | 66O02. 66-ELEVATOR PIT FOR DEVICE NUMBER 1P22405 IS DIRTY/ACCUMULATED PAPER AND OTHER DEBRIS | $0 | $0 | Jul 1, 2004 |
| Mar 13, 2003 | 34336711R | RESOLVE | Hazardous | FAILURE TO MAINTAIN EXTERIOR OF BUILDING. IMPROPERTY INSTALLED WINDOW A.C. ON THE 7TH FLOOR ON THE WEST ELEV. ALSO ON... | $0 | $0 | May 1, 2003 |
| Aug 13, 2002 | 34338980Y | RESOLVE | Non-Hazardous | WORK W/O A PERMIT ( SIDE WALK SHED ) AT TIME OF INSECTION 40' LONG SIDE WALK SHED WAS ERECTED ON THE FRONT OF THE BLD... | $0 | $0 | Oct 3, 2002 |
| Jun 27, 2001 | 38116825X | RESOLVE | Non-Hazardous | 75U05 PERFORM 5 YEAR FULL LOAD TEST AND FILE 61H12 REPLACE WORN TILLER ROPE | $180 | $0 | Aug 16, 2001 |
| Jul 24, 1998 | 34160937N | RESOLVE | Non-Hazardous | FAILURE TO FILE A REPORT OF COMPLIANCE WITH LOCAL LAW 16/84 CERTIFYINGTO THE INSTALLATION OF REQUIRED FIRE PROTECTION... | $0 | $0 | Sep 22, 1998 |
| Jul 24, 1998 | 34160938P | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE ELEVATOR LANDING SIGN AT ELEVATOR'S BANK ON FLOORS 2 TO 17. FAILURE TO PROVIDE STAIR & ELEVATOR 3"... | $7,500 | $0 | Sep 17, 1998 |
| Apr 28, 1995 | 38049124X | RESOLVE | Non-Hazardous | 73X11 RESTORE TO SERVICE | $0 | $0 | Jul 20, 1995 |
| Dec 21, 1990 | 34052917H | RESOLVE | Non-Hazardous | FAILURE TO FILE A REPORT OF COMPLIANCE WITH LOCAL LAW 16/84 CERTIFYINGTO THE INSTALLATION OF REQUIRED FIRE PROTECTION... | $500 | $0 | Apr 25, 1991 |
| Nov 1, 1989 | 32004036Z | RESOLVE | Non-Hazardous | FILE 900A FORMS WITH THE PERMIT # FROM THE PLANNING DWN OF NYC TO THE DEPT OF BLDGS BOIELR DIVISION | $0 | $0 | Dec 14, 1989 |