69 Murray Street, Manhattan
Manhattan • Block 00132 • Lot 0003 • Zip: 10007
Condition
What the city currently has open against this building, counted from its own records.
Address
Land use and zoning
Building
Latest assessment
Neighborhood
The area this lot falls inside, and the commute Hoodkit measures from it.
Getting around
Estimated 3 days ago- Fulton Street 14 min 2 walking, 12 riding
- Penn Station 15 min 2 walking, 13 riding
- Times Square 17 min 2 walking, 15 riding
- Union Square 18 min 2 walking, 16 riding
- Downtown Brooklyn 20 min 2 walking, 18 riding
- Grand Central 23 min 2 walking, 21 riding
Around this address
Transit and places within 0.5 miles of the lot.
Getting out
Subway
Railroad
Ferry
Bus
Citi Bike
Places nearby
Bubby's
No description yet
Metropolis
No description yet
Jungsik
No description yet
Huso
No description yet
Casa Carmen
No description yet
Restaurant Marc Forgione
No description yet
The Odeon
The Odeon is a classic French bistro in the heart of Tribeca, offering a stylish and lively atmosphere. Known for its...
Le Gratin
Le Gratin is a hidden gem in the heart of NYC, offering a unique dining experience with a focus on French cuisine. Th...
Activity
Sales, filings, permits and violations from every dataset, in one order.
2026
-
CLASS - 2
AT THE TIME OF INSPECTION OF A 10 STORY BUILDING WITH PERMITTED SIDEWALK SHED IN PLACE. NO ACTIVE CONSTRUCTION WORK O...
2025
-
DOB violation Aug 4, 2025
C-CONSTRUCTION OTHER OPTIONAL
FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. OBSERVED SPALLING STUCCO ON EXPOSURE 4. CRACKED STUCCO ON EX...
2024
-
HPD violation Apr 1, 2024
Class A
(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ...
2023
-
HPD violation Mar 15, 2023
Class A
(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ...
2022
-
DOB violation Apr 1, 2022
FISPFCS-FAILURE TO CORRECT SWARMP CONDITIONS (FACADE) FACADE REQUIRED
CYCLE 9C FAILURE TO CORRECT SWARMP CONDITIONS
-
DOB violation Apr 1, 2022
FISPHAZ-HAZARDOUS CONDITION (FACADE) FACADE REQUIRED
CYCLE 9C UNSAFE REPORT FILED
-
HPD violation Feb 16, 2022
Class A
(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ...
2021
-
CLASS - 2
FAILURE TO MAINTAIN EXTERIOR FACADE AND APPURTENANCES.AT SOUTH ELEVATION EXP1 OBSERVED VERTICAL CRACKS AND OPEN JOINT...
2020
-
Alteration Type II
INTERIOR RENOVATION OF STORE (NAIL SHOP) AT 1ST FLOOR. WORK INCLUDES REMOVAL/INSTALLATION OF NON-LOAD-BEARING PARTITI...
2016
-
DOB violation Feb 18, 2016
E-ELEVATOR ELEVATORREQUIRED
2015
-
DOB violation Feb 17, 2015
E-ELEVATOR ELEVATORREQUIRED
-
CLASS - 1
UNLAWFULLY CONTINUED WORK WHILE ON NOTICE OF A STOP WORK ORDER.(REMOVAL OF SUPPORTED SCAFFOLD W/O REINSPECTION) NOTED...
-
Alteration Type II
INTERIOR RENOVATION OF 10TH FLOOR RESIDENTIAL SPACE AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
2014
-
Alteration Type II
FILING FOR THE RENOVATION OF AN EXISTING APARTMENT. REARRANGEMENT OF NON LOAD BEARING PARTITIONS, DOORS, FLOORING, CE...
-
Alteration Type II
FILING FOR THE DIRECT REPLACEMENT OF THE EXISTING MAIN ENTRANCE DOOR AS SHOWN ON DRAWINGS FILED HEREWITH. NO CHANGE I...
-
Alteration Type III
SIDEWALK SHED PROPOSED INSTALLATION OF SIDEWALK SHED AS PER PLAN NO CHANGE IN USE, OCCUPANCY OF EGRESS UNDER THIS APP...
-
Alteration Type III
PIPE SCAFFOLD PROPOSED INSTALLATION OF PIPE SCAFFOLD AS PER PLAN NO CHANGE IN USE, OCCUPANCY OF EGRESS UNDER THIS APP...
-
CLASS - 2
3314.8,PARTIAL SWO ISSED FOR SUPPORTED SCAFFOLD PURSUANT 28-207.2 & POSTED ON PREMISES.GUARDRAIL SYSTEM & TOEBOARDS.N...
-
DOB violation May 15, 2014
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
-
CLASS - 2
WORK DOES NOT CONFORM TO APPROVED CONTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS. NOTED: AT TIME OF INSPECTION DIST...
2013
2012
2008
-
CLASS - 2
FAILED TO NOTIFY THE DEPT/OBTAIN PERMIT PRIOR TO USE/INSTALLATION OF "C" HOOKS IN CONNECTION W/ SUSPENDED SCAFFOLD. R...
The most recent 6 events from each dataset, so no one source takes the axis. Each tab holds the full record.
Property Contacts
Contact information aggregated from multiple government sources
Registration Contracts
Contact information from multiple dwelling registrations
Building Permits
Owner information from Department of Buildings filings
Recent Building Permits
Owner information from recent DOB NOW filings
Deed Records
Parties from ACRIS deed and mortgage records
Property Records
Owner information from assessment and PLUTO records