ECB violations
81 Warren Street, Manhattan • Block 00132 • Lot 0123
16 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Mar 3, 2022 | 35578797P | RESOLVE | CLASS - 2 | ALT/CHANGED BLDG OCCUPIED W/O VALID C/O AS PER28-118.3.1-28-118.3.2 NOTED:ATOI,NO VALID C/O OR TCO ON FILE FOR WORK D... | $0 | $0 | Jun 2, 2022 |
| Nov 24, 2017 | 35285496M | RESOLVE | CLASS - 2 | PARTIAL STOP WORK ORDER FOR SUPPORTED SCAFFOLD PURSUANT TO 28-207 & POSTED @ PREMISES WORK DOES NOT CONFORM TO APPROV... | $250 | $0 | Jan 11, 2018 |
| Nov 21, 2017 | 35285438Y | RESOLVE | CLASS - 2 | FAILURE TO POST/PROPERLY PERMIT FOR WORK @ PREMISES. @ TIME OF INSP OBSERVED A SIDEWALK SHED INSTALLED BUT NO PERMIT ... | $0 | $0 | Jan 11, 2018 |
| Oct 13, 2017 | 35287834P | RESOLVE | CLASS - 2 | BC3314.8 FAILURE TO PROVIDE REQUIRED GUARDRAILS AND TOE-BOARDS FOR SCAFFOLD PLATFORM. AT THE TIME OF INSPECTION IT WA... | $0 | $0 | Dec 21, 2017 |
| Oct 13, 2017 | 35287831J | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS. AT THE TIME OF INSPECTION IT WAS OBSERVED AN ACTI... | $400 | $0 | Jul 26, 2018 |
| Oct 13, 2017 | 35287833N | RESOLVE | CLASS - 1 | BC3309.10 FAILURE TO PROTECT ADJOINING ROOFS, SKYLIGHTS, CHIMNEYS AND OUTLETS AFFECTED BY CONSTRUCTION OR DEMOLITION ... | $400 | $0 | Jul 26, 2018 |
| Oct 13, 2017 | 35287832L | RESOLVE | CLASS - 2 | BC3307.3.1 SIDEWALK SHED/INADEQUATE. AT THE TIME OF INSPECTION IT WAS OBSERVED AN ACTIVE CONSTRUCTION SITE WITH SIDEW... | $0 | $0 | Dec 21, 2017 |
| Oct 13, 2017 | 35287837K | RESOLVE | CLASS - 2 | BC3303.8 FAILURE TO PROVIDE OR MAINTAIN REQUIRED TEMPORARY OR PERMANENT STANDPIPE IN A STATE OF READINESS AS REQUIRED... | $0 | $0 | Dec 21, 2017 |
| Oct 13, 2017 | 35287836Z | RESOLVE | CLASS - 2 | BC3308.5 FAILURE TO INSTALL OR MAINTAIN VERTICAL SAFETY NETTING SYSTEMAS REQUIRED. AT THE TIME OF INSPECTION IT WAS O... | $0 | $0 | Dec 21, 2017 |
| Oct 13, 2017 | 35287838M | RESOLVE | CLASS - 1 | CONSTRUCTION SUPERINTENDENT FAILED TO PERFORM DUTIES AS PER RULE. AT THE TIME OF INSPECTION IT WAS OBSERVED THAT ON A... | $2,500 | $0 | Jul 26, 2018 |
| Oct 13, 2017 | 35287830H | RESOLVE | CLASS - 1 | ELECTRICAL WORK WITHOUT A PERMIT. AT THE TIME OF INSPECTION IT WAS OBSERVED AN ACTIVE CONSTRUCTION SITE WHERE TEMPORA... | $400 | $0 | Jul 26, 2018 |
| Jun 13, 2017 | 35239017Z | RESOLVE | CLASS - 1 | SEC: BC3301.2. FAILURE TO MAINTAIN. @ TIME OF INSP OF A 6 STORY BLDG @ 6 FLR LEVEL, CONSTRUCTION WORK IN PROGRESS OBS... | $400 | $0 | Dec 14, 2017 |
| Jun 13, 2017 | 35239019M | RESOLVE | CLASS - 1 | SEC: BC 3308.5. @ TIME OF INSP OF A 6 STORY ALTERATION BLDG, @ 6TH LEVEL FLR, CONSTRUCTION WORK IN PROGRESS, OBSERVED... | $1,600 | $0 | Dec 14, 2017 |
| Jun 13, 2017 | 35239016R | RESOLVE | CLASS - 2 | SEC: 1RCNY 3301-02. LOGS. @ TIME OF INSP OF A 6 STORY BLDG A 6 FLR LEVEL, STEEL ERECTED A 5TH & 6TH FLR, CONSTRUCTION... | $0 | $0 | Aug 3, 2017 |
| Jun 13, 2017 | 35239015P | RESOLVE | CLASS - 1 | FAILURE TO DESIGNATE &/OR HAVE CONSTRUCTION SUPERINTENDENT PRESENT @ SITE WHEN REQUIRED. @ TIME OF INSP OF A 6 STORY ... | $1,600 | $0 | Dec 14, 2017 |
| Jun 13, 2017 | 35239018K | RESOLVE | CLASS - 2 | SEC: BC 3309.10. ROOF PROTECTION. @ TIME OF INSP OF A 6 STORY ALTERATION BLDG, OBSERVED A MISSING ROOF PROTECTION @ E... | $0 | $0 | Aug 3, 2017 |