ECB violations
24-26 Harrison Street, Manhattan • Block 00181 • Lot 0041
12 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Oct 9, 2008 | 34699262N | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING WALL. LOCATION NOTED: EXPOSURE #1 HANGING CORNICES CORRODED AND STRUCTURAL UNSTABLE. REM... | $0 | $0 | Jan 15, 2009 |
| May 10, 2008 | 34645516K | RESOLVE | Hazardous | FAILURE TO MAINTAIN EXTERIOR OF BLDG FRONT OF BLDG HAS METAL MARQUEE THAT IS RUSTING AND FAILING. PCS OF METAL HAVE F... | $2,000 | $0 | Jun 26, 2008 |
| Dec 10, 2007 | 34587636M | RESOLVE | Hazardous | FAILURE TO MAINTAIN EXTERIOR OF BLDG. NOTED: @ TIME OF INSPECTION I FOUND THAT @ EXPOSURE (1) @ THE GROUND FLR RETAIL... | $800 | $0 | Apr 2, 2008 |
| Jan 17, 2006 | 34504717H | RESOLVE | Hazardous | FAILURE TO MAINTAIN: METAL DOORS & SUPPORTS IN SIDEWALK OVER SIDEWALK VAULT IN DISREPAIR & NOT ADEQUATELY SUPPORTED. ... | $2,000 | -$2,000 | Mar 16, 2006 |
| Nov 18, 2005 | 38156190H | RESOLVE | Non-Hazardous | 84K11. (84-K-11) CABLE USED TO RUN ELEVATOR NEED'S TOO BE REPLACED RUSTED. | $0 | $0 | Jan 5, 2006 |
| Nov 15, 2005 | 34484688M | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN. NOTE AT CELLAR LEVEL AT VARIOUS LOCATION FLOOR JOISTS RATTED AND DEFECTIVE, ALSO SIDEWALK VAULT ... | $0 | $0 | Jan 5, 2006 |
| Sep 29, 2005 | 34484520Z | RESOLVE | Hazardous | FAILURE TO MAINTAIN BLDG NOTED: SIDEWALK VAULT AT FRONT OF BLDG WOOD FLOOR BEAMS ROTTED AND IN DANGER OF COLLAPSING I... | $800 | $0 | Nov 17, 2005 |
| May 27, 2004 | 34416194H | RESOLVE | Hazardous | FAILURE TO MAINTAIN BLDG DEFECT: SEVERAL WOODEN FLOOR JOINTS (1STY) AT REAR (NORTH) ARE WATER ROTTED IN CELLAR AREA -... | $800 | $0 | Jul 15, 2004 |
| Dec 6, 2002 | 38134179J | RESOLVE | Non-Hazardous | 48H12/ 49H12/ 34P07/ 79O02 | $0 | $0 | Apr 24, 2003 |
| Aug 19, 2002 | 34335934J | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT. PARTITIONS ADN CEILING HAS BEEN REMOVED ON THE THIRD FLOOR ( ENTIRE) REMEDY: OBTAIN PERMIT. | $500 | $0 | Aug 7, 2003 |
| Sep 24, 1997 | 38064526Y | RESOLVE | Non-Hazardous | 73X#-RESTORE ELEVATOR SERVICE SO PROPER INSPECTION CAN BE MADE BY THISDEPT. | $1,000 | $0 | Feb 5, 1998 |
| Apr 8, 1994 | 38041648K | RESOLVE | Non-Hazardous | 73X | $100 | $0 | Aug 18, 1994 |