Issued Violation Status Severity Description Penalty Balance due Hearing
Aug 6, 2013 35007539N RESOLVE CLASS - 2 SEC. 1009.2 FAILURE TO PROVIDE MINIMUM STAIRWAYS HEADROOM OF 84 INCHES. NOTED: BLDG HAVING ON STAIRWAY (PRIMARY MEANS... $0 $0 Dec 5, 2013
Aug 6, 2013 35007540K RESOLVE CLASS - 2 SEC. 1008.1.1.3 FAILURE TO PROVIDE MINIMUM DOOR HEIGHT. NOTED: BLDG HAVING FIRE EXIT DOORS LEADING INTO THE STAIRCASE... $0 $0 Dec 5, 2013
Aug 6, 2013 35007541M RESOLVE CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER: USE OF PROHIBITED DOOR & OR DOOR HARDWARE PER BC 1008.1.8;27-371(J... $0 $0 Dec 5, 2013
Aug 6, 2013 35007542Y RESOLVE CLASS - 1 FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. NOTED: ON 2ND FL IN THE BACK OF RECEPTION ROOM. ACCESS TO THE FIRE E... $0 $0 Dec 5, 2013
Aug 6, 2013 35007543X RESOLVE CLASS - 1 SEC. 1019.1.1 FAILURE TO COMPLY W/OPENING PROTECTIVES REQUIREMENTS FORVERTICAL EXIT ENCLOSURES. NOTED: EXIT DOORS LEA... $0 $0 Dec 5, 2013
Aug 6, 2013 35007544H RESOLVE CLASS - 1 SEC. 1009.11. FAILURE TO PROVIDE HANDRAILS FOR STAIRWAYS. NOTED: STAIRWAY FROM STREET INTO CELLAR HAVING BOILER ROOM ... $0 $0 Dec 5, 2013
Aug 6, 2013 35007545J RESOLVE CLASS - 1 SEC. 1509.8;27-334 FAILURE TO PROVIDE PROTECTIVE GUARDS. NOTED: 6 STORY BLDG HAVING FLAT ROOF W/O PROTECTIVE GUARDS A... $0 $0 Dec 5, 2013
Aug 6, 2013 35007547N RESOLVE CLASS - 1 WORK W/O A PERMIT. ILLEGAL WORK NOTED: ON 5TH FL - ENTIRE ERECTED 8'-0" DRYWALL BOARDS PARTITIONS ALONG CORRIDORS,CRE... $0 $0 Dec 5, 2013
Aug 6, 2013 35007548P RESOLVE CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: DEFECTIVE,NON FUNCTIONAL FIRE ALARM SYSTEM FOR OCCUPIED FLO... $0 $0 Dec 5, 2013
May 26, 2011 34907397Y RESOLVE CLASS - 2 BC1008.1.13 FAILURE TO PROVIDE MINIMUM DOOR HEIGHT NOTED BLDG HAVING FIRE EXIT DOORS LEADING INTO THE STAIR CASE APPX... $0 $0 Jul 21, 2011
May 26, 2011 34907393R RESOLVE CLASS - 1 BC715.3 FAILURE TO PROVIDE FIRE RATED DOOR AS PER BC715.3 AND TABLE 715.3 NOTED BLDG HAVING ON 2ND AND 5TH FLOOR SUN ... $1,600 $0 Oct 6, 2011
May 26, 2011 34907395K RESOLVE CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER NOT FIRE STOPPING PER BC 712.3 27-345 NOTED BLDG HAVING IN CELLAR B... $1,000 $0 Oct 6, 2011
May 26, 2011 34907392P RESOLVE CLASS - 1 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERT OF OCCUPANCY OR BLDG DEPT RECORDS NOTED BLDG HAVING CONVERTED ENTIRE 2... $2,400 $0 Oct 6, 2011
May 26, 2011 34907391N RESOLVE CLASS - 1 FAILURE TO PROVIDE REQUIRED MEANS OF EGRESS FROM ROOM OR SPACE NOTED BLDG HAVING OCCUPIED 2ND & FLOOR AS TRANSIENT MO... $1,600 $0 Oct 6, 2011
May 26, 2011 34907427X RESOLVE CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER ILLUMINATION FOR EXITS EXIT DISCHARGES & PUBLIC CORRIDORS PER BC100... $1,000 $0 Oct 6, 2011
May 26, 2011 34907399H RESOLVE CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER USE OF PROHIBITED DOOR AND OR DOOR HARDWARE PER BC1008.1.8 27-371M ... $1,000 $0 Oct 6, 2011
May 26, 2011 34907396M RESOLVE CLASS - 2 FAILURE TO PROVIDE MINIMUM STAIRWAYS HEADROOM OF 84INCHES NOTED BLDG HAVING ON STAIRWAY 2ND & 3RD FLOOR LVL APPX 78IN... $0 $0 Jul 21, 2011
May 26, 2011 34907426Y RESOLVE CLASS - 1 BC1008.4.3 FAILURE TO MEET EGRESS EXIT AND EXIT DISCHARGE REQUIREMENTS LOCATED ON 2ND TO 5TH FLOORS 24" DOUBLE HUNG W... $0 $0 Oct 6, 2011
May 26, 2011 34907425M RESOLVE CLASS - 1 FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY NOTED BLDG HAVING ON 5TH FLOOR SUN HOTEL FIRE EXIT DOOR LEADING INTO ... $400 $0 Oct 6, 2011
May 26, 2011 34907394Z ACTIVE CLASS - 2 WORK W/O A PERMIT WORK NOTED BLDG HAVING INSTALLED ON 2ND FLOOR AT REAR OF RECEPTION SPACE 3 WASHER & DRYER MACHINES ... $800 $0 Oct 6, 2011
May 26, 2011 34907428H RESOLVE CLASS - 1 FAILURE TO MAINTAIN BLDG IN COMPLIANT MANNER LACK OF EMERGENCY POWER OR STORAGE BATTERY CONNECTION TO EXIT SIGNS PER ... $4,800 $0 Oct 6, 2011
Feb 12, 2009 34765665K RESOLVE CLASS - 2 FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES NOTED:AT NORTH ELEVATION CHIPPING SPALLING PEELING PAINT IN VARIOUS L... $2,500 $0 Apr 9, 2009
Jun 14, 2006 34518486R ACTIVE Non-Hazardous WORK W/O A PERMIT. WORK NOTED/ON 1ST FL FULL HEIGHT PARTITIONS WERE INSTALLED ALSO NEW DUCT WORK & NEW FL JOIST MAKIN... $250 $0 Aug 3, 2006
Jan 28, 1991 34053040P RESOLVE Non-Hazardous FAILURE TO FILE A REPORT OF COMPLIANCE WITH LL 16/84 CERTIFYING TO THE INSTALLATION OF REQUIRED FIRE PROTECTION SYSTEMS $400 $0 May 16, 1991
Aug 4, 1988 34011365H RESOLVE Hazardous FAILURE TO MAINTAIN BUILDING WALL. MORTAR JOINTS OPEN, BRICKWORK CRACKED, LOOSE AND BULDING OUT OF PLUMB AT SOUTH EXT... $1,560 $0 Sep 22, 1988
Jul 26, 1988 34011151M RESOLVE Hazardous FAILURE TO MAINTAIN EXTERIOR BUILDING WALL DEFECT IS MORTAR JOINTS OPERN BRICKWORK CRACKED LOOSE AND BLDG OUT OF PLUM... $1,560 $0 Sep 15, 1988
Jul 12, 1988 34010175M ACTIVE Hazardous FAILURE TO MAINTAIN. CONCRETE SIDEWALK AND STEEL SUPPORTING BEAMS OVER VAULT HAVE COLLAPSED INTO CELLAR AT ENTRANCE T... $1,000 $0 Sep 1, 1988
Jun 27, 1988 34007921H RESOLVE Hazardous FAILURE TO MAINTAIN EXTERIOR BUILDING WALL. DEFECT IS: MORTAR JOINTSOPEN, BRICKWORK CRACKED AND LOOSE AND BUILDING OU... $625 $0 Aug 18, 1988
Jun 10, 1988 34007726M RESOLVE Hazardous CONCRETE SIDEWALK & STEEL SUPPORTING BEAMS HAVE COLLAPSED INTO INTERIOR OF SIDEWALK VAULT AT CELLAR LEVEL AT FRONT OF... $625 $0 Jul 28, 1988