ECB violations
West Street, Manhattan • Block 00216 • Lot 0001
83 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Apr 1, 2021 | 37021228J | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8A REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... | $0 | $0 | Jan 20, 2022 |
| Mar 30, 2021 | 37020911J | RESOLVE | CLASS - 2 | 27-929.1 FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL SPRINKLER REP... | $3,125 | $0 | Mar 24, 2022 |
| Dec 3, 2020 | 35544747L | RESOLVE | CLASS - 1 | SEC. 3301.1 FAILURE TO COMPLY W/OSHA(RULES)& REGULATIONS AS PER 3301.1. AT TIME OF INSPECTION ON AN ACTIVE JOBSITE OF... | $2,500 | $0 | Jun 24, 2021 |
| Dec 3, 2020 | 35544746J | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN/DISPLAY ON SITE DRAWINGS/DOCUMENTS REQUIRED BY CHAPTER 33. AT TIME OF INSPECTIOIN ON AN ACTIVE JO... | $2,500 | $0 | Jun 24, 2021 |
| Mar 30, 2020 | 37018951L | RESOLVE | CLASS - 2 | 27-929.1 FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL SPRINKLER REP... | $0 | $0 | Oct 15, 2020 |
| Mar 30, 2020 | 37018870J | ACTIVE | CLASS - 2 | SEC. 27-929.1 AC 27-929.1 FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS & FILE A FINA... | $3,125 | $0 | Oct 8, 2020 |
| Nov 15, 2019 | 37016783M | RESOLVE | CLASS - 2 | BC27-929.2/A.C. 27-929.1,FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FIN... | $0 | $0 | Dec 10, 2020 |
| Nov 15, 2019 | 37016054M | RESOLVE | CLASS - 2 | 27-929.1 A.C. 27-929-1,FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL... | $3,125 | $0 | Feb 13, 2020 |
| Nov 8, 2019 | 35452317N | RESOLVE | CLASS - 2 | VIOLATION OF DISCRETIONARY ZONING CONDITIONS ON PRIVATELY OWNED PUBLICSPACE NOTED:AS PER ZONING RESOLUTION CHARTER(7)... | $625 | $0 | Aug 6, 2020 |
| Sep 10, 2019 | 35446758H | RESOLVE | CLASS - 1 | FAILURE TO INSTITUTE AND MAINTAIN SAFETY MEASURES.IN RESPONSE TO AN ACCIDENT WHERE IT WAS REPORTED BY SSM CARPENTER(A... | $0 | $0 | Jan 28, 2021 |
| Sep 10, 2019 | 35419015N | RESOLVE | CLASS - 1 | FAILURE TO NOTIFY THE DEPARTMENT OF AN INCIDENT THAT RESULTED IN A FATALITY OR INJURY NOT ONE WORKER GOT CAUGHT BETWE... | $5,000 | $0 | Apr 23, 2020 |
| Sep 6, 2019 | 35419011X | RESOLVE | CLASS - 1 | FAILURE TO NOTIFY THE DEPARTMENT OF AN INCIDENT THAT RESULYE DIN A AFATALITY OR INJURY NOTED A WORKER TRIPPED ON HIS ... | $5,000 | $0 | Apr 23, 2020 |
| Dec 17, 2018 | 35360700H | RESOLVE | CLASS - 2 | CRANE USER BENSON INDUSTRIES CN#336/16 USING CRANE @ 107 NORTH MOORE ST FAILED TO THE DEPARTMENT OF THE CRANES DEPART... | $5,000 | $0 | Mar 21, 2019 |
| Jul 12, 2018 | 35342825M | RESOLVE | CLASS - 1 | MATERIAL STORAGE @LEADING EDGE.@TIME OF INSP ON A ACTIVE A 39 STORY BLDG,OBSERVED IMPROPER MATERIAL STORED @LEADING E... | $2,500 | $0 | Aug 30, 2018 |
| Jul 11, 2018 | 35336074J | RESOLVE | CLASS - 1 | BC 3308.5.3 CABLE/ SYSTEM (GUARDRAILS) INADEQUATE @TIME OF INSP ON AN ACTIVE JOBSITE OF 39 STORY BLDG I OBERVED FROM ... | $2,500 | $0 | Aug 30, 2018 |
| May 18, 2018 | 37011165M | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT ACCEPTABLE 8TH ROUND REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALLS AND APP... | $1,250 | $0 | Feb 21, 2019 |
| May 18, 2018 | 37011164K | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT ACCEPTABLE 8TH ROUND REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALLS AND APP... | $3,125 | $0 | Oct 25, 2018 |
| Nov 30, 2017 | 35300901J | RESOLVE | CLASS - 1 | BC3314.11.5.3.PROTECTIVE COVERS.NOTE:AT THE TIME OF MY INSPECTION OF A39 STORY BUILDING UNDER ALTERATION,CONSTRUCTION... | $1,600 | $0 | Feb 22, 2018 |
| Nov 30, 2017 | 35300900H | RESOLVE | CLASS - 1 | BC3314.11.5.2.INSULATING MATERIAL.NOTE:AT THE TIME OF MY INSPECTION OFA 39 STORY BUILDING UNDER ALTERATION,CONSTRUCTI... | $1,600 | $0 | Feb 22, 2018 |
| Nov 30, 2017 | 35300902L | RESOLVE | CLASS - 2 | BC3314.4.3.2.(BC3301.7)INSTALLATION FOR SUSPENDED SCAFFOLD.NOTE:AT THETIME OF INSPECTION OF A BUILDING UNDER ALTERATI... | $400 | $0 | Feb 22, 2018 |
| Nov 30, 2017 | 35301574X | RESOLVE | CLASS - 1 | BC3303.10.OPERATING IN OCCUPIED BUILDINGS.NOTE:AT TIME OF MY INSPECTION OF A BUILDING UNDER ALTERATION,CONSTRUCTION W... | $1,600 | $0 | Jun 21, 2018 |
| Nov 30, 2017 | 35300903N | RESOLVE | CLASS - 1 | BC3301.1.2.FAILURE TO COMPLY WITH NYC FIRE CODE-GENERAL-NO FIRE WATCH,FIRE GUARD,CERTIFICATE OF FITNESS.NOTE:AT TIME ... | $1,600 | $0 | Jun 21, 2018 |
| Oct 21, 2017 | 38255888N | RESOLVE | CLASS - 2 | 42B10. 42B10 ESCALATOR FAILS TO HAVE A VARIABLE FREQUENCY REGENRATIVE DRIVE AS PER SECTION REQUIREMENTS.REM:COMPLY WI... | $0 | $0 | Nov 24, 2017 |
| Oct 21, 2017 | 38255885H | RESOLVE | CLASS - 2 | 42B10. 42B10 ESCALATOR FAILS TO COMPLY WITH ASME A17.1/CSA OR LOCAL CODE WHEN NOT CONVEYING PASSENGERS.REM:COMPLY WIT... | $0 | $0 | Nov 24, 2017 |
| Oct 21, 2017 | 38255886J | RESOLVE | CLASS - 2 | 42B10. 42B10 ESCALATOR FAILS TO HAVE A VARIABLE FREQUENCY REGENERATIVEDRIVE AS PER SECTION REQUIREMENTS.REM:COMPLY WI... | $0 | $0 | Nov 24, 2017 |
| Oct 21, 2017 | 38255887L | RESOLVE | CLASS - 2 | 42B10. 42B10 ESCALATOR FAILS TO COMPLY WITH ASME 17.1/CSA OR LOCAL CODE WHEN NOT CONVEYING PASSENGERS.REM:COMPLY WITH... | $0 | $0 | Nov 24, 2017 |
| Sep 13, 2017 | 38255705L | RESOLVE | CLASS - 2 | 42B10 EXCALATOR FAILS TO HAVE A VARIABLE FREQUENCY REGENERATIVE DRIVEAS PER SECITON REQUIREMENTS. RMDY: COMPLY WITH C... | $0 | $0 | Nov 24, 2017 |
| Sep 13, 2017 | 38255706N | RESOLVE | CLASS - 2 | 42B10 EXCALATOR FAILS TO HAVE A VARIABLE FREQUENCY REGENERATIVE DRIVE AS PER SECTION REQUIREMENTS.RMDY: COMPLY WITH C... | $0 | $0 | Nov 24, 2017 |
| Sep 13, 2017 | 38255708R | RESOLVE | CLASS - 2 | 42B10 EXCALATOR FAILS TO COMPLY WITH ASME A17.1/ CSA ON LOCAL CODE WHEN NOT CONVEYING PASSENGERS. RMDY: COMPLY WITH C... | $0 | $0 | Nov 24, 2017 |
| Sep 13, 2017 | 38255704J | RESOLVE | CLASS - 2 | 42B10 EXCALATOR FAILS TO HAVE A VARIABLE FREQUENCY REGENERATIVE DRIVE AS PER SECTION REQUIREMENTS.RMDY: COMPLY WITH C... | $0 | $0 | Nov 24, 2017 |
| Sep 13, 2017 | 38255709Z | RESOLVE | CLASS - 2 | 42B10 ESCALATOR FAILS TO COMPLY WITH ASME A.17.1 / CSA AS LOCL CODE WHEN NOT CONVEYING PASSENGERS. RMDY: COMPLY WITH ... | $0 | $0 | Nov 24, 2017 |
| Sep 13, 2017 | 38255707P | RESOLVE | CLASS - 2 | 42B10 EXCALATOR FAILS TO COMPLY WITH ASME A17.1/ CSA ON LOCAL CODE WHEN NOT CONVEYING PASSENGERS. RMDY: COMPLY WITH C... | $0 | $0 | Nov 24, 2017 |
| May 10, 2017 | 35244160H | RESOLVE | CLASS - 1 | WORK WITHOUT PERMIT-WORK AFTER HOURS WITHOUT A VARIANCE CONTRARY TO 28-105.12.5;WORK IN PROGRESS UNDER PERMIT#1045412... | $800 | $0 | Jun 29, 2017 |
| Apr 27, 2017 | 35225191R | RESOLVE | CLASS - 2 | OPERATION OF CRANE W/O A C OF O APPROVAL/NO CD-SEE SWO#042717RH01 AT TIME OF INSPECTION AUDIT,RESPONDENT ABOCE USED K... | $2,400 | $0 | Aug 17, 2017 |
| Apr 27, 2017 | 35225185K | RESOLVE | CLASS - 1 | SUPERVISION OR USE OF POWER OPERATED MACHINE W/O A HOISTING MACHINE OPERATORS LICENSE/SEE SWO#042717RH01 AT TIME OF I... | $1,600 | $0 | Aug 17, 2017 |
| Apr 27, 2017 | 35225190P | RESOLVE | CLASS - 2 | OPERATION OF CRANE W/O CERTIFICATE OF APPROVAL/OPERATION/NO CD-SEE SWO#002717RH01 AT TIME OF INSPECTION AUDIT,RESPOND... | $2,400 | $0 | Jul 27, 2017 |
| Apr 27, 2017 | 35225195Y | RESOLVE | CLASS - 2 | OPERATION OF A CRANE W/O A CERTIFICATE OF ON SITE INSPECTION,NO CN-SEESWO#042717RH01 AT TIME OF INSPECTION AUDIT,RESP... | $2,400 | $0 | Jul 27, 2017 |
| Apr 27, 2017 | 35225189H | RESOLVE | CLASS - 1 | OPERATING AN ARTICULATING BOOM CRANE W/O A CERTIFICATE OF APPROVAL-SEE SWO#042717RH01 AT TIME OF AUDIT INSPECITON,M C... | $1,000 | $0 | Jul 27, 2017 |
| Apr 27, 2017 | 35225184Z | RESOLVE | CLASS - 1 | SUPERVISION OR USE OF POWER OPERATED MACHINE W/O A HOISTING MACHINE OPERATORS LICENSE. SEE SEO#042717RH01 AT TIME OF ... | $1,600 | $0 | Jul 27, 2017 |
| Apr 27, 2017 | 35225188X | RESOLVE | CLASS - 1 | OPERATING AN ARTILULATING BOOM CRANE W/O A CERTIFICATE OF APPROVAL-SEE SWO#042717RH01 ATT IME OF AUDIT INSPECTION,G/C... | $0 | $0 | Aug 17, 2017 |
| Apr 27, 2017 | 35225192Z | RESOLVE | CLASS - 2 | OPERATION OF CRANE W/O A C PF P APPROVAL NO CD-SEE SWO#042717RH01 AT TIME OF INSPECTION AUDIT,RESPONDENT ABOVE USED K... | $0 | $0 | Jun 15, 2017 |
| Apr 27, 2017 | 35225187Y | RESOLVE | CLASS - 1 | OPERATING AN ARTICULATING BOOM CRANE W/O CERTIFICATE OF APPROVAL. SEE SWO#042717RH01. AT TIME OF AUDIT INSPECTION LIF... | $0 | $0 | Jun 15, 2017 |
| Apr 27, 2017 | 35225186M | RESOLVE | CLASS - 1 | SUPERVISION OR USE OF POWER OPERATED MACHINE W/O A HOISTING MACHINE OPERATORS LICENSE-SEE SWO#242717RH01. AT TIME OF ... | $0 | $0 | Jun 15, 2017 |
| Apr 27, 2017 | 35225196X | RESOLVE | CLASS - 2 | OPERATION OF A CRANE WITHOUT A CERTIFICATE OF ON SITE INSPECTION/NO CN-SEE SWO #042717RH01 AT TIME OF INSPECTION AUDI... | $0 | $0 | Aug 17, 2017 |
| Apr 27, 2017 | 35225193K | RESOLVE | CLASS - 2 | OPERATION OF A CRANE W/O A CERTIFICATE OF ON SITE INSPECTION NO CN(CRANE NOTICE).SEE SWO#042717RH01 AT TIME OF INSPEC... | $2,400 | $0 | Aug 17, 2017 |
| Dec 2, 2016 | 35212255Y | RESOLVE | CLASS - 1 | 3310.3 FAILURE TO HAVE SITE SAFETY PLAN AND PROGRAM AS REQUIRED.NOTE:AT THE TIME OF MY INSPECTION OF A 39 STORY BUILD... | $1,600 | $0 | Feb 22, 2017 |
| Dec 2, 2016 | 35212256X | RESOLVE | CLASS - 1 | 3303.10 TENANT PROTECTION PLAN-OCCUPIED BUILDING.NOTE:AT THE TIME OF MY INSPECTIONOF A 39 STORY BUILDING UNDER ALTERA... | $1,600 | $0 | Feb 22, 2017 |
| Nov 25, 2016 | 35212253K | RESOLVE | CLASS - 1 | BC3308.10 TENANT PROTECTION PLAN-OCCUPIED BLDGS. NOTE: AT THE TIME OF MY INSPECTION OF A 39 STORY BLDG UNDER ALTERATI... | $1,600 | $0 | Mar 16, 2017 |
| Nov 25, 2016 | 35212254M | RESOLVE | CLASS - 1 | PRESENSE AT SITE. NOTE: AT THE TIME OF MY INSP. OF A 39 STORY ALTERATION JOB CONSTRUCTION WORK IN PROGRESS. RESPONDIN... | $1,200 | $0 | Feb 16, 2017 |
| Oct 11, 2016 | 35201664L | RESOLVE | CLASS - 1 | ELECTRICAL WRK W/OUT A PERMIT.TEMPORARY WIRING.THE ENTIRE BLDG TEMPORARY WIRING,GROUND FLR-CONSTRUCTION OFFICE CELLAR... | $800 | $0 | Dec 1, 2016 |