ECB violations
147-151 Lafayette Street, Manhattan • Block 00234 • Lot 0017
24 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Oct 17, 2019 | 35447092P | RESOLVE | CLASS - 2 | BC3307.6.4.8/PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS.NOTE:AT TIME OF INSPECTION OBSERVED A SWS AND SU... | $5,000 | $5,000 | Dec 26, 2019 |
| Feb 27, 2018 | 35250148X | RESOLVE | CLASS - 2 | WORK W/O A PERMIT. NOTED: OBSERVED AT TIME OF INSPECTION RENOVATION WORK IN PROGRESS IN THE REAR OF THE 4TH FL EXISTI... | $500 | $0 | Jul 2, 2018 |
| May 6, 2015 | 38235670M | RESOLVE | CLASS - 2 | 98BB05;70O02 | $2,500 | $0 | Jun 25, 2015 |
| Sep 15, 2010 | 32069419N | RESOLVE | CLASS - 2 | 6A,15,16,32A,38,50,50A-C.(50)COMBUSTIBLE STORAGE IN BOILER ROOM.(50A)BOILER PIT SUMP PUMP DEFECTIVE.(50B)OIL TANK SIG... | $250 | $0 | Nov 4, 2010 |
| Aug 20, 2009 | 34803771Z | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. NOTED: SUPPORTED SCAFFOLD BEING USED... | $2,400 | $0 | Feb 4, 2010 |
| Sep 11, 2006 | 34470741P | RESOLVE | Hazardous | WORK CONTRARY TO APPROVED PLANS & APPLICATION. OPERATION OF CRANE, DERRICK, OR HOISTING EQUIPMENT IN A UNSAFE MANNER ... | $0 | $0 | Nov 16, 2006 |
| Jun 27, 2006 | 32050123Y | RESOLVE | Non-Hazardous | 50A,50B,50C,50D/FULTON VT BOILER, 10HP, NB 58679, GAS, 1989/50A-HIGH PRESSURE STEAM BOILER IN OPERATION ON OPEN FACTO... | $0 | $0 | Aug 17, 2006 |
| Oct 4, 2005 | 38155452Y | RESOLVE | Non-Hazardous | 05I10/16M07/58E01/63A07 (05) CAR GATE NOT BALANCED, PULLING UP DEAD WEIGHT OF GATE REPAIR. (16) HOISTWAY DOOR STRAPS ... | $0 | $0 | Nov 17, 2005 |
| Oct 4, 2005 | 38155453X | RESOLVE | Non-Hazardous | 59X10/#M07/19B01/* (59) MACHINE ROOM LIGHTS INOPERATIVE REPAIR (#) CAB RAILING MISSING PROVIDE (19) HOISTWAY DOOR CLO... | $0 | $0 | Nov 17, 2005 |
| Aug 10, 2004 | 32045859K | RESOLVE | Non-Hazardous | 50A/50B FUCTON V.T BOILER 10HP NB 58679 HAS 1989 50A-CORROSION ON BLOWDOWN LINE NEAR BOILER 50B-NO DISCHARGE PIPE ON ... | $0 | $0 | Sep 30, 2004 |
| Mar 7, 2003 | 32041479K | RESOLVE | Non-Hazardous | 50A/50B. 50A THE BLOW DOWN VALVE AREA UNDERATER. THEY SHOWN BE TWO SLOW OPENING VALVES OR ONE QUICK OPENING AND ONE S... | $0 | $0 | Apr 24, 2003 |
| Feb 11, 2002 | 32026270Y | RESOLVE | Non-Hazardous | 44C/ 49/ 49) MUST INSTALL DISCHARGED PIPE ON SAFTEY VALUE DISCHARGE PIPE MISSING 49B ) WATER COLOM DRAIN LINE IS REDU... | $180 | $0 | Aug 29, 2002 |
| Feb 11, 2002 | 32026269R | RESOLVE | Non-Hazardous | 19A/44C/49. 49- MUST INSTALL A DISCHRGE PIPE ON SAFETY VALVE. DISCHARGE PIPE MISSING. 49B- WATER LOLOM DRAIN LINE IS ... | $0 | $0 | Jun 6, 2002 |
| Dec 4, 2000 | 32019794J | RESOLVE | Non-Hazardous | 49, 32A. MUST INSTALL DRAIN LINE ON SITE GLASS, TRI COOKS HANDLE MISSING, WATER COLOM DRAIN LINE IS REDUCED, NO DISCH... | $180 | $0 | Mar 15, 2001 |
| Dec 4, 2000 | 32019793H | RESOLVE | Non-Hazardous | 49. 49)LOW WATER CUTOFF MANUAL RESET NOT COMMECTES MUST RECONNENT FULTON HI PRESSURE FBOIOA BOILER NB#47812 1985 YEAR. | $2,500 | $0 | Feb 15, 2001 |
| Dec 4, 2000 | 32019795L | RESOLVE | Non-Hazardous | 16,18A,48B,49. 49) NO BLOW DOWN LINE ON SITE GLASS. FULTON HIGH PRESURE BOILER FB015A NB#48231 1985 YEAR. | $2,500 | $0 | Feb 15, 2001 |
| Dec 4, 2000 | 32019796N | RESOLVE | Non-Hazardous | 18A,49,16. 49) NO DISCHARGE PIPE ON SITE GLASS,NO DISCHARGE PIPE ON SAFETY VALUE MUST REMOVE SHOUTOFF VALUE FROM FEED... | $2,500 | $0 | Feb 15, 2001 |
| Aug 20, 1999 | 34222771N | RESOLVE | Hazardous | REQUIRED MEANS OF EGRESS OBSTRUCTED. NOTED: LAFAYETTE STAIRCASE USED FOR STORAGE ON STAIRS & PUBLIC LANDINGS. AT 6 FL... | $400 | $0 | Oct 7, 1999 |
| Jul 19, 1996 | 34142378R | RESOLVE | Non-Hazardous | IURE TO MAINTAIN EXTERIR BULIDUING WALL IN THAT CEMENT PLATER ON BRICK WALL OBOVE PARAPET ON TEH WEST SIDE OF BUILDIN... | $800 | $0 | Oct 24, 1996 |
| Jul 23, 1991 | 34058619R | RESOLVE | Hazardous | FAILURE TO MAINTAIN DEFECT ARE:PARAPET WALL LOOSE,AND CRACKED STUCCO,FALLING HAZARDOUS CONDITION LOCATION:FRONT 215 C... | $720 | $0 | Sep 5, 1991 |
| Dec 27, 1988 | 32001612Y | RESOLVE | Non-Hazardous | — | $0 | $0 | Feb 16, 1989 |
| Dec 27, 1988 | 32001611M | RESOLVE | Non-Hazardous | — | $75 | $0 | Feb 16, 1989 |
| Aug 17, 1988 | 34012373M | RESOLVE | Non-Hazardous | USE OF ILLEGAL HARDWARE, FIRE EXIT DOORS AT THE 5TH STORY ARE EQUIPPED WITH ILLEGAL SLIDE BOLTS. REMEDY: REMOVE ILLEG... | $100 | $0 | Oct 6, 1988 |
| Jul 13, 1988 | 32000555M | RESOLVE | Unknown | — | $125 | $0 | Sep 1, 1988 |