Maintenance code violations
35 Market Street, Manhattan • Block 00277 • Lot 0021
106 records
HPD grades a violation A for non-hazardous through C for immediately hazardous.
| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| Apr 29, 2026 | A | NOV SENT OUT | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ... | — | Aug 2, 2026 |
| Dec 4, 2025 | B | NOV SENT OUT | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES... | — | Jan 8, 2026 |
| Dec 1, 2025 | B | VIOLATION DISMISSED | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICA... | — | Jan 5, 2026 |
| Dec 1, 2025 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING A... | — | Jan 5, 2026 |
| Dec 1, 2025 | A | VIOLATION DISMISSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT PUBLIC HALL, 1... | — | Mar 6, 2026 |
| Apr 1, 2024 | A | VIOLATION DISMISSED | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION ... | — | Jul 5, 2024 |
| Jan 17, 2023 | A | INVALID CERTIFICATION | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AND NORTH WALL AT... | — | Apr 22, 2023 |
| Jan 17, 2023 | B | INVALID CERTIFICATION | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIALS AT CEILING ... | — | Feb 21, 2023 |
| Dec 7, 2021 | C | VIOLATION CLOSED | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF METAL GARBAGE RECEPTACLES OBSTRUCTING THE FIRE ESCA... | — | Dec 13, 2021 |
| Nov 30, 2021 | C | VIOLATION CLOSED | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF METAL GARBAGE RECEPTACLES OBSTRUCTING THE FIRE ESCA... | — | Dec 6, 2021 |
| Nov 30, 2021 | C | NOV SENT OUT | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF AIR CONDITIONER UNIT INSTALLED AT FIRE ESCAPE WINDO... | 6A | Dec 6, 2021 |
| Nov 30, 2021 | B | NOV SENT OUT | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE 2nd ROOM FROM NORTH LOCA... | 6A | Jan 4, 2022 |
| Nov 30, 2021 | C | NOV SENT OUT | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ... IN THE E... | 6A | Dec 26, 2021 |
| Nov 30, 2021 | A | NOV SENT OUT | § 27-2005 ADM CODE REFIT THE BUILDING ENTRANCE DOOR | — | Mar 5, 2022 |
| Nov 30, 2021 | C | NOV SENT OUT | § 27-2028, 2032 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FROM AN APPROVED CENTRAL HEATING SYSTEM, OR AN APPROVED S... | 6A | Nov 30, 2021 |
| Nov 30, 2021 | B | NOV SENT OUT | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 6A, 6th STO... | 6A | Jan 4, 2022 |
| Nov 12, 2021 | A | NOV SENT OUT | § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED... | — | Feb 15, 2022 |
| Nov 12, 2021 | A | NOV SENT OUT | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COM... | — | Feb 15, 2022 |
| Aug 23, 2021 | C | VIOLATION CLOSED | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF METAL GARBAGE RECEPTACLES OBSTRUCTING DROP LADDER A... | — | Aug 29, 2021 |
| Aug 23, 2021 | B | NOV SENT OUT | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICA... | — | Sep 27, 2021 |
| Aug 23, 2021 | A | NOV SENT OUT | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COM... | — | Nov 26, 2021 |
| Aug 23, 2021 | B | NOV SENT OUT | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED... | 3C | Sep 27, 2021 |
| Aug 23, 2021 | B | NOV SENT OUT | § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE ... | 3C | Sep 27, 2021 |
| Aug 23, 2021 | B | NOV SENT OUT | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING A... | — | Sep 27, 2021 |
| Aug 23, 2021 | B | NOV SENT OUT | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HAND MADE SHELF OBSTRUCTING THE FIRE ESCAPE WINDOW ... | 3C | Sep 27, 2021 |
| Aug 23, 2021 | B | NOV SENT OUT | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3C, 3rd STOR... | 3C | Sep 27, 2021 |
| Aug 23, 2021 | B | DEFECT LETTER ISSUED | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING APPROX.10.SQ.FT. SOUT... | 3C | Sep 27, 2021 |
| Aug 23, 2021 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS PANE AT UPPER WINDOW SASH AT SOUTH WALL IN THE 1st ... | 3C | Aug 29, 2021 |
| Aug 23, 2021 | B | NOV SENT OUT | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AND EAST WALL IN TH... | 3C | Sep 27, 2021 |
| Aug 23, 2021 | B | NOV SENT OUT | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT EAST WALL... | — | Sep 27, 2021 |
| Aug 23, 2021 | A | NOV SENT OUT | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT PUBLIC HALL, 1... | — | Nov 26, 2021 |
| Jun 21, 2021 | A | NOV SENT OUT | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WEST AND SOUTH WALL... | 5B | Sep 24, 2021 |
| Jun 21, 2021 | C | NOV SENT OUT | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 4... | 5B | Jun 27, 2021 |
| Jun 21, 2021 | B | NOV SENT OUT | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 4th ROOM FRO... | 5B | Jul 26, 2021 |
| Dec 31, 2020 | A | VIOLATION DISMISSED | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE ... | — | Apr 5, 2021 |
| Dec 31, 2020 | A | VIOLATION DISMISSED | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING R... | — | Apr 5, 2021 |
| Nov 26, 2018 | B | VIOLATION DISMISSED | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 1A, 1st STORY,... | 1A | Dec 31, 2018 |
| Nov 26, 2018 | B | NOV SENT OUT | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE .. IN THE EN... | 1A | Dec 31, 2018 |
| Nov 26, 2018 | B | VIOLATION DISMISSED | § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 1st STORY, 1s... | 1A | Dec 31, 2018 |
| Nov 26, 2018 | B | VIOLATION DISMISSED | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICA... | 1A | Dec 31, 2018 |
| Nov 26, 2018 | B | VIOLATION DISMISSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE KITCHEN LOCA... | 1A | Dec 31, 2018 |
| Nov 26, 2018 | C | VIOLATION DISMISSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE K... | 1A | Dec 4, 2018 |
| Nov 26, 2018 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 3... | 1A | Dec 31, 2018 |
| Nov 26, 2018 | B | VIOLATION DISMISSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE B... | 1A | Dec 31, 2018 |
| Nov 26, 2018 | B | VIOLATION DISMISSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOC... | 1A | Dec 31, 2018 |
| Mar 12, 2018 | A | NOT COMPLIED WITH | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING R... | — | Jun 15, 2018 |
| Mar 12, 2018 | A | NOT COMPLIED WITH | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COM... | — | Jun 15, 2018 |
| Mar 12, 2018 | A | NOT COMPLIED WITH | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE ... | — | Jun 15, 2018 |
| Feb 6, 2018 | C | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCKING AND ASSEMBLY AT FRONT ENTRANCE DOOR TO BUILDING , ... | — | Feb 14, 2018 |
| Feb 6, 2018 | C | NOV SENT OUT | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCK LEADING TO BOILER ROOM AT PUBLIC HALL, ... | — | Feb 14, 2018 |