Skip to content

ECB violations

11 Essex Street, Manhattan • Block 00297 • Lot 0024

45 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Feb 20, 2026 39550619N RESOLVE CLASS - 1 AT THE TIME OF MY INSPECTION OF A 10-STORY NEW BUILDING ACTIVE JOB SITE, FIRE HYDRANTS WERE OBSERVED IN USE. UPON REQ... $2,500 $2,500 Nov 20, 2026
Feb 20, 2026 39550620K RESOLVE CLASS - 1 AT THE TIME OF INSPECTION OF A 10-STORY NEW BUILDING ACTIVE JOB SITE, A FIRE HYDRANT WAS OBSERVED IN USE WITHOUT A RE... $2,500 $2,500 Nov 20, 2026
Jan 24, 2026 39549508M RESOLVE CLASS - 2 AT TIME OF INSPECTION, OBSERVED SIDEWALK SHED INSTALLED WITH SHORING CONNECTED TO BEAMS NOT SHOWN OR REFLECTED ON APP... $0 $0 May 7, 2026
Jan 24, 2026 39549507K RESOLVE CLASS - 2 AT TIME OF INSPECTION, OBSERVED SIDEWALK SHED NOT PROPERLY MAINTAINED; A BROKEN MUDSILL WAS USED AS THE BASE FOR CORN... $2,500 $2,500 May 7, 2026
Jan 24, 2026 39549504P RESOLVE CLASS - 1 AT TIME OF INSPECTION, OBSERVED JERSEY BARRIERS NOT INSTALLED OR MAINTAINED PER MANUFACTURER SPECIFICATIONS; BARRIERS... $2,530 $2,530 Mar 25, 2027
Dec 22, 2025 39548279N RESOLVE CLASS - 2 OBSERVATION: @ EXPOSURE #1 NO VIEWING PANELS FOR CONSTRUCTION FENCE. VIO FOR FAILURE TO CONSRUCT/MAINTAIN CONSTRUCTIO... $1,000 $0 Feb 26, 2026
Dec 21, 2025 39548263Z RESOLVE CLASS - 2 OBSERVATION: @ EXPOSURE #1 NETTING LOOSE BETWEEEN FENCE & SIDEWALK SHED WITH OPENINGS, HAZARDOUS CONDITION OF LOOSE/O... $2,500 $0 Feb 26, 2026
May 29, 2025 35693912P RESOLVE CLASS - 1 NO SITE-SPECIFIC FORMWORK DESIGN DRAWING PRESENT PER 3301.7. AS NOTED AT TIME ON AN ACTIVE CONSTRUCTION SITE, 9 STORY... $2,500 $2,500 Feb 12, 2026
May 29, 2025 35693916M RESOLVE CLASS - 2 CONSTRUCTION SUPERINTENDENT FAILED TO PERFORM DUTIES PER CODE. AS NOTED AT TIME OF INSPECTION ON AN ACTIVE CONSTRUCTI... $5,000 $5,000 Feb 12, 2026
May 29, 2025 35693911N RESOLVE CLASS - 1 FAILURE TO OBTAIN REGISTERED DESIGN PROFESSIONAL EVALUATION PRIOR TO EXISTING STRUCTURE TO SUPPORT FORMWORK LOADS. AS... $5,000 $5,000 Feb 12, 2026
May 29, 2025 35693915K RESOLVE CLASS - 2 FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS. ASNOTED AT TIME OF INSPECTION ON AN ACTIVE CONSTR... $1,250 $1,250 Feb 12, 2026
May 13, 2025 39540165Z RESOLVE CLASS - 2 AT THE TIME OF INSPECTION I OBSERVED HOIST NOT ACTIVE 40 FT BELOW WORKING DECK AS REQUIRED TO BE IN THE STATE OF READ... $2,500 $2,500 Aug 27, 2026
May 13, 2025 39540158K RESOLVE CLASS - 1 AT THE TIME OF INSPECTION ACTIVE SITE I OBSERVED PIPE SCAFFOLDING WITH NETTING INSTALLED AT THE 9TH FLOOR LEVEL ENCRO... $10,000 $10,000 Aug 27, 2026
Mar 19, 2025 39538131H RESOLVE CLASS - 1 FAILURE TO COMPLY WITH 3307.4 WARNING SIGNS, AND BARRIERS. I OBSERVED STORED MATERIALS ON STREET LEVEL AT THE EXPOSUR... $5,030 $5,030 Oct 29, 2026
Feb 28, 2025 39537468Z RESOLVE CLASS - 2 AT TIME OF INSPECTION I OBSERVED CONSTRUCTION OFFICE TRAILER ON THE ROADWAY, UPON REVIEWING CONSTRUCTION DOCUMENTS IT... $1,250 $1,250 Nov 19, 2026
Feb 28, 2025 35664679P RESOLVE CLASS - 2 MAINTAIN DOCUMENT ON SITE. @ THE TIME ON INSPECTION OBSERVED 3" RIGID INSULATION EXP #3, 4 AND PARTIAL OF EXP #2, AS ... $3,125 $3,125 Nov 2, 2026
Feb 28, 2025 39537466P RESOLVE CLASS - 2 AT TIME OF INSPECTION I OBSERVED FENCE APPROX. 8 FEET MADE OF YODOKS BARRIERS AND CHAIN LINK FENCE ON THE ROADWAY, UP... $2,500 $2,500 Nov 19, 2026
Feb 28, 2025 39537467R RESOLVE CLASS - 2 AT TIME OF INSPECTION I OBSERVED STORAGE ZONE IN ROAD WAY NOT CONSTRUCTED AT PER CODE (3307.4.7) WHERE FENCE OR BARRI... $2,500 $2,500 Nov 19, 2026
Feb 28, 2025 39537465N RESOLVE CLASS - 2 I OBSERVED A SWS ERECTED AT EXPO# 1 WITH MISSING INFORMATION PANEL AS REQUIRED BY CODE (3301.9.2.1.1) WHICH INCLUDES ... $1,250 $1,250 Nov 19, 2026
Apr 24, 2020 35439819R RESOLVE CLASS - 1 MATERIAL FALSE STATEMENT THE RESPODENT SPECIAL INSPECTION APPLICANT VIOLATED AC28-211.1 WHICH MANDATES THAT IT SHALL ... $5,000 $0 Feb 4, 2021
Apr 24, 2020 35439818P RESOLVE CLASS - 1 MATERIAL FALSE STATEMENT HE RESPONDENT REGISTERED DESIGN PROFESSIONAL VIOLATED AC 28-211.1 WHCIH MANDATES THAT IT SHA... $5,000 $0 Feb 4, 2021
Mar 13, 2020 35439817N RESOLVE CLASS - 2 BC3314.3.3&BC1603.1-DEFICIENT DRAWINGS THE RESPONDENT REGISERED DEIGN PROFESSIONAL FAILED O MEET THE MINIMUM REQUIREM... $625 $0 Feb 4, 2021
Mar 13, 2020 35439816L RESOLVE CLASS - 1 BC3314.14-DEFICIENT DESIGN THE RESPONDENT DESIGN PROFESSIONAL FAILED TO MEET THE MINIMUM REQUIREMENTS SET FORTH IN BC... $2,500 $0 Feb 4, 2021
Feb 12, 2020 35462838H RESOLVE CLASS - 2 POSTING OF UNLAWFULL SIGN,GRAFFITI,PICTORAL REPRESENTATION ON CONSTRUCTION PROTECTIVE STRUCTURE(FENCE)AT TIME OF INSP... $0 $0 Apr 23, 2020
Jan 6, 2020 35468552J RESOLVE CLASS - 1 WORK CONTRARY TO PLANS{DEBRIS CHUTE}AT THE TIME OF MY INSPECTION OF A 6 STORY BUILDING BEING DEMOLISHED,I OBSERVED TH... $0 $0 Oct 21, 2021
Jan 6, 2020 35468554N RESOLVE CLASS - 1 FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING.AT THE TIME OF MY INSPECTIONOF A 6 STORY BUILDING BEING DEMOLISHED,I OBSERV... $625 $0 Oct 21, 2021
Jan 6, 2020 35468553L RESOLVE CLASS - 1 BC3307654-STORAGE OR PLACEMENT OF ITEMS ON SIDEWALK SHED.AT THE TIME OF MY INSPECTION OF A 6 STORY BUILDING BEING DEM... $625 $0 Oct 21, 2021
Jan 6, 2020 35468551H RESOLVE CLASS - 1 LOGS{FAILURE TO OBSERVED UNSAFE CONDITIONS}AT THE TIME OF MY INSPECTION,I OBSERVED THAT THE CONSTRUCTION SUPERINTENDE... $0 $0 Oct 21, 2021
Nov 16, 2009 34816832X RESOLVE CLASS - 1 FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS:NOTED PREMISES HAS BEEN VACATED BY DO... $2,400 $0 Jan 7, 2010
Apr 29, 2009 34775475Z RESOLVE CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. THE INTERIOR FLR JOISTS SAGGING AROUND STAIRCASE LOCATION CAUSING ... $1,000 $0 Oct 16, 2009
Apr 29, 2009 34775481P RESOLVE CLASS - 1 FAILURE TO MAINTAIN BLDG WALL(S) OR APPURTENANCES. DEFECTS NOTED: AT REAR OF PREMISES (EXPOSURE #3). 1) HORIZONTAL AN... $2,500 $0 Sep 24, 2009
Sep 25, 2007 34593954Z RESOLVE Hazardous FAILURE TO MAINTAIN BLDG EXTERIOR WALL. HAZARDOUS. NOTED: AT THE TIME OF INSPECTION I FOUND THAT WORK HAD BEEN DONE, ... $10,000 $0 Nov 15, 2007
May 14, 2007 34546122Y RESOLVE Hazardous FAILURE TO MAINTAIN EXTERIOR BLDG WALL.NOTED:A 3' X 3' SECTION OF BRICKS HAVE COLLAPSED AT.THE 2FL LEVEL & STONE HEAD... $2,500 $0 Jul 12, 2007
May 2, 2007 34546121M RESOLVE Non-Hazardous FAILURE TO MAINTAIN EXTERIOR BLDG WALL NOTED:A 3'X 3'SECTION OF BRICKSHAVE COLLAPSED @ 2ND FL LEVEL & STONE HEADER @ ... $800 $0 Aug 16, 2007
Apr 21, 2007 34572115P RESOLVE Hazardous FAILURE TO MAINTAIN EXTERIOR BLDG WALL (HAZ) DEFECTS NOTED: REAR WALL SOUTH/WEST CORNER 2ND FL BULGING & MISSING BRIC... $800 $0 Aug 16, 2007
Mar 26, 2007 34572103H RESOLVE Non-Hazardous FAILURE TO MAINTAIN EXTERIOR BLDG WALL.(HAZ)DEFECTS NOTED:ON 2ND FL APPROX 5' X 5' SECTION OF BRICKWALL MISSING FROM ... $800 $0 Aug 16, 2007
Mar 26, 2007 34572102X RESOLVE Non-Hazardous FAILURE TO COMPLY W/COMMISSIONERS ORDER TO CORRECT THE VIOLATING CONDITION AND FILE A CERTIFICATE OF CORRECTION W/THE... $500 $0 Aug 16, 2007
Sep 6, 2005 34490311N RESOLVE Non-Hazardous FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER TO CORRECT THE VIOLATING CONDITION AND FILE A CERTIFICATE OF CORRECTIO... $0 $0 Oct 27, 2005
Nov 23, 2004 34455538Y RESOLVE Non-Hazardous BUILDING ALTERED REDUCING THE RQUIRED STANDARS OF OUTDOOR SUPPLY NOTED::EXISTING OPEN THE SHELF HAS BEEN COVERED BY 4... $0 $0 Jan 13, 2005
Sep 2, 2004 34431387J RESOLVE Non-Hazardous FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPT OF BUILDINGS FOR VIO... $0 $0 Oct 28, 2004
Jul 22, 2004 34443863J RESOLVE Non-Hazardous FAILURE TO MAINTAIN BLDG WALL NOTE: AT REAR FACADE SIGNIFICANT BULGINGOF BRICK WALL AT 2ND FLOOR WITH CRACKS IN MASON... $2,000 $0 Oct 28, 2004
Mar 4, 2004 34431380R RESOLVE Non-Hazardous FAILURE TO MAINTAIN EXTERIOR BLDG WALL.NOTED:SOUTH EAST CORNER OF REARWALL HAS CRACKS ABOVE AND BELOW WINDOWS ON ALL ... $800 $0 Oct 28, 2004
Aug 1, 2001 34299977Y RESOLVE Hazardous WORK WITHOUT A PERMIT.(35% OF WORK COMPLETED)NOTED:BEARING & REAR EXTERIOR WALLS ENLARGED AT DOOR & WINDOW OPENINGS.E... $800 $0 Nov 1, 2001
Aug 1, 2001 34299978X RESOLVE Hazardous NO GUARD RAILS NOTED OPENING IN BASEMENT FLOOR IN NUMEROUS PLACES WITH NO GUARD RAILS CREATING DANGER OF FALLING INTO... $0 $0 Nov 1, 2001
Aug 1, 2001 34299979H RESOLVE Non-Hazardous FAILURE TO PROTECT ADJOINING STRUCTURES DURING EXCAVATION OPERATIONS NOTED DEBRIS FROM DEMOLITION OF BASEMENT & CELLA... $1,000 $0 Nov 1, 2001