Skip to content

ECB violations

130 Hester Street, Manhattan • Block 00303 • Lot 0015

125 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Jan 20, 2010 34833151P RESOLVE CLASS - 1 FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS.NOTED AT TIME OF INSPECTION FORMING 1... $1,600 $0 Aug 5, 2010
Jan 20, 2010 34833153Z RESOLVE CLASS - 1 RESHORES WITHIN 10FT OF BLDG EDGE ARE SECURED,BANDED & TIED TO STRUCTURE.NOTED:AT TIME OF INSPECTION RESHORES ON FLOO... $1,600 $0 Aug 5, 2010
Jan 20, 2010 34833155M RESOLVE CLASS - 2 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS.NOTED:AT TIME OF INSPECTION ON AC... $0 $0 Mar 11, 2010
Jan 20, 2010 34833154K RESOLVE CLASS - 2 SEC.BC28-105.12.8.WORK IS NOT IN ACCORDANCE W/SITE SAFETY PLAN.SITE SAFETY PLAN NEEDS TO BE UPDATED SHOWING ALL CHANG... $0 $0 Mar 11, 2010
Jan 20, 2010 34826773Y RESOLVE CLASS - 2 FAILURE TO POST DOT PERMIT FOR STREET/SIDEWALK CLOSING.NOTED AT TIME OF INSPECTION ALL 3 COPIES OF DOT PERMITS WERE N... $0 $0 Mar 11, 2010
Jan 20, 2010 34826771K RESOLVE CLASS - 2 SEC.BC3301.9.REQUIRED SIGNS.THE SIGNS REQUIRED SHALL BE CONSTRUCTED OF3/4 INCH PLYWOOD OR SHEET METAL.THE LETTERS ON ... $0 $0 Mar 11, 2010
Jan 20, 2010 34826770Z RESOLVE CLASS - 2 SEC.BC3307.8.STANDARD GUARD RAIL. STANDARD GUARDRAIL SHALL CONSIST OF A 2INCH X 4INCH WOOD TOP RAIL OR EQUIVALENT CAP... $0 $0 Mar 11, 2010
Jan 20, 2010 34826765Y RESOLVE CLASS - 2 FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS.NOTED:AT TIME OF INSPECTION ON ACTIVE CONSTRUCTION... $0 $0 Mar 11, 2010
Jan 20, 2010 34826764M RESOLVE CLASS - 2 SEC.BC3301.2.FAILURE TO INSTITUTE & MAINTAIN SAFETY EQUIPMENT MEASURESOR TEMP CONSTRUCTION HOLES IN FL.NOTED:AT TIME ... $0 $0 Mar 11, 2010
Jan 20, 2010 34826761R RESOLVE CLASS - 2 JOB SITE FENCE NOT CONSTRUCTED PURSUANT TO SUBSECTION.NOTED AT TIME OFINSPECTION 8FT CONSTRUCTION FENCE NOT BUILT SOL... $0 $0 Mar 11, 2010
Jan 20, 2010 34826760P RESOLVE CLASS - 2 SEC.BC3301.9. FOLLOWING THE RECEIPT OF A PERMIT TO ERECT A MATERIAL ORPERSONAL HOIST THE PERMIT HOLDER SHALL POST A S... $0 $0 Mar 11, 2010
Dec 21, 2009 34786141M RESOLVE CLASS - 2 3306.12.FAILURE TO PROVIDE ELEVATOR INREADYNESS AT THE TIME OF MY INSPECTION.STRUCTURE UPTO 11 FL ELEVATOR/HOIST IS N... $0 $0 Feb 11, 2010
Dec 16, 2009 34786134Y RESOLVE CLASS - 1 SEC. 3303.8 FAILURE TO PROVIDE STANDPIPE AT REQUIRED HEIGHT. @ THE TIME OF MY INSPECTION APPROX 23 WORKER ON SITE. BL... $1,600 $0 Jun 17, 2010
Dec 16, 2009 34786135X RESOLVE CLASS - 1 SEC. 3308.1.3 FAILURE TO JUMP HORIZONTAL NETS AT THE REQUIRED HIGH ALLOWED BY CODE. @THE TIME OF MY INSPECTION APPROX... $1,600 $0 Jun 17, 2010
Dec 16, 2009 34786138L RESOLVE CLASS - 2 SEC. 3303.1.3 FAILURE TO BUILD CONTRACTOR SHED BY FIRE RETARDANT TREATED MATERIALS. @ THE TIME OF INSPECTION APPROX 2... $0 $0 Feb 4, 2010
Dec 16, 2009 34786136H RESOLVE CLASS - 1 SEC. 3301.2 HOLE / OPENING NOT COVERED. @ THE TIME OF MY INSPECTION APPROX 23 WORKERS ON SITE. I OBSERVED ON THE 6, 7... $1,600 $0 Jun 17, 2010
Dec 16, 2009 34786137J RESOLVE CLASS - 1 SEC. 3308.3 VERICAL SAFETY NETTING MISSING. @ THE TIME OF MY INSPECTION. APPROX 23 WORKERS ON SITE. STRUCTURAL UP TO ... $1,600 $0 Jun 17, 2010
Nov 21, 2009 34786125M RESOLVE CLASS - 2 FAIL TO POST PERMIT FOR WRK @ PREMISES @ THE TIME OF MY INSP WRK IN PROGRESS APPROX 15 WRK MEN ON SITE FORMING 9 FLR.... $400 $0 Jul 15, 2010
Nov 17, 2009 34786206Y RESOLVE CLASS - 2 SEC. 1905.632. FAILURE TO PROVIDE CURING BOX. NOTED: AT THE TIME OF INSP RESPONDENT NAME ABOVE FAILED TO PROVIDE TEST... $400 $0 Jun 3, 2010
Nov 17, 2009 34786208H RESOLVE CLASS - 2 SEC. 1RCNY5-02(A)(B). FAILURE TO PROVIDE EMPLOYEE W/PHOTO ID. NOTED: @THE TIME OF INSPECTION TECH ROMMELL L. VELEZ #0... $0 $0 Jan 7, 2010
Nov 17, 2009 34786118Y RESOLVE CLASS - 2 FAIL TO SAFEGUARD ALL PERSONS/PROPERTY AFFECTED BY CONST OPERATIONS. AT THE TIME OF INSPECTION APPROX 30 WORK MEN ON ... $1,200 $0 Jun 3, 2010
Nov 17, 2009 34786117M RESOLVE CLASS - 2 SEC 3301.10 MISC VIOL: OBSCURED LAWFUL SIGNS. AT THE TIME OF INSPECTION APPROX 30 WORK MEN ON SITE STRUCTURAL UP TO T... $0 $0 Jan 7, 2010
Nov 17, 2009 34786116K RESOLVE CLASS - 2 FAIL TO INSTITUTE MAINTAIN SAFETY EQUIPMENT MEASURES. AT THE TIME OF INSP CONST SITE STRUCTURAL UP TO 8 FL APPROX 30 ... $0 $0 Jan 7, 2010
Nov 17, 2009 34786207X RESOLVE CLASS - 2 SEC. 1RCNY5-02(A)(B). FAILURE TO PROVIDE EMPLOYEE W/PHOTO ID. NOTED: @THE TIME OF INSPECTION TECH ROMMELL L. VELEZ #0... $0 $0 Jan 7, 2010
Aug 31, 2009 34805862N RESOLVE CLASS - 2 SEC. BC 3301.7 FAILURE TO PROVIDE DESIGN DRAWING FOR SAFETY STRAPS. NOTE: AT TIME OF INSPECTION AT ABOVE SITE. BUILDI... $0 $0 Oct 22, 2009
Aug 31, 2009 34805864R RESOLVE CLASS - 2 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS. NOTE: AT TIME OF INSPECTION AT A... $250 $0 Mar 25, 2010
Aug 31, 2009 34805863P RESOLVE CLASS - 2 SEC. 28-103.8 MATTERS NOT PROVIDED FOR. NOTE: AT TIME OF INSPECTION AT ABOVE SITE. BUILDING UP TO 6TH FLR,OBSERVED TH... $0 $0 Oct 22, 2009
Aug 5, 2009 34799299P RESOLVE CLASS - 1 FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. NOTED: DUE TO CONSTRUCTION OPERATION... $2,400 $0 Feb 18, 2010
Jul 28, 2009 38204973H RESOLVE CLASS - 1 97L11-RESP FAILED TO COMPLY WITH RULES #26.4.4 & #26.7 OF ANSI A10.4-1981.THE RESP HAS A HISTORY OF NON-COMPLIANCE WI... $0 $0 Apr 7, 2011
Jul 6, 2009 34790461N RESOLVE CLASS - 2 JOB SITE FENCE NOT CONSTRUCTED PURSUANT TO SUBSECTION. AS NOTED: AT TIME OF INSPECTION ON A ACTIVE CONSTRUCTION SITE,... $0 $0 Aug 27, 2009
Jul 6, 2009 34790462P RESOLVE CLASS - 2 SEC. BC 3301.7,27-1015 DESIGN. AS NOTED: AT TIME OF INSPECTION ON A ACTIVE CONSTRUCTION SITE,BUILDING UP TO 6 STORIES... $0 $0 Aug 27, 2009
Jul 6, 2009 34790460L RESOLVE CLASS - 1 SEC. BC 3310.3 PLANS/SITE SAFETY NOT FILED. AS NOTED: AT TIME OF INSPECTION ON A ACTIVE CONSTRUCTION SITE,BUILDING UP... $1,600 $0 Apr 29, 2010
Jun 3, 2009 34783196X RESOLVE CLASS - 1 PROVOF LAW BC3310.8.2 SITE SAFETY MANAGER/COORDINATOR FAILED TO IMMEDIATELY NOTIFY THE DOB OF CONDITION AS REQUIRED.N... $1,600 $0 Jul 23, 2009
Jun 3, 2009 34783195Y RESOLVE CLASS - 1 FAILURE TO SAFEGUARD ALL PERSON & PROPERTY AFFECT BY CONSTRUCTION OPERATIONS. NOTED: AT TIEM OF INSPECTION ON ACTIVE ... $12,000 $0 Apr 2, 2010
Jun 3, 2009 34783194M RESOLVE CLASS - 1 PROVISION OF ALW 1906.6.1.2 RESHORES IN PROXIMITY OF FACADE (RESHORES WITHIN 10FT OF THE FACADE OF A BUILDING SHALL B... $8,000 $0 Aug 12, 2010
Jun 3, 2009 34783193K RESOLVE CLASS - 1 FAILURE TO INSTITUTE & MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION (NO TOE BOARDS) NOTED: AT TIME OF... $1,000 $0 Aug 12, 2010
Jun 3, 2009 34783192Z RESOLVE CLASS - 1 FAILURE TO SAFEGUARD ALL PERSON AND PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. NOTED: AT TIME OF INSPECTION ON ACT... $12,000 $0 May 27, 2010
Mar 20, 2009 34778602X RESOLVE CLASS - 1 SEC 27-157 28-104.7.1 UNDERPINNING PLANS ARE NOT ADEQUATE IN THAT PLANS ARE NOT COMPLETE & OF SUFFICIENT CLARITY TO I... $0 $0 Jul 21, 2011
Mar 20, 2009 34778603H RESOLVE CLASS - 1 SEC 28-1704.9.1 FAILURE TO CARRY OUT CONTROLLED INSP RESPONSIBLITIES IN AN APPROPRIATE MANNER TO ENSURE WAS PROCEEDIN... $1,600 $0 Jul 21, 2011
Mar 20, 2009 346915892 RESOLVE CLASS - 1 FAILURE TO CARRY OUT CONTROLLED INSPECTION RESPONSIBILITIES IN AN APPROPRIATE MANNER TO ENSURE WAS PROCEEDING SAFELY ... $0 $0 May 14, 2009
Mar 20, 2009 34691589Z RESOLVE CLASS - 1 27-132 FAILURE TO CARRY OUT CONTROLLED INSPECTION RESPONSIBILITIES IN AN APPROPRIATE MANNER TO ENSURE WAS PROCEEDING ... $0 $0 Apr 1, 2010
Mar 20, 2009 34691590X RESOLVE CLASS - 1 "STOP ALL WORK". UNDERPINNING PLANS ARE NOT ADEQUATE IN THAT PLANS ARE NOT COMPLETE AND/OR SUFFICIENT CLARITY TO INDI... $0 $0 Apr 12, 2010
Mar 9, 2009 34759120J RESOLVE CLASS - 2 SEC. 3304.4.3 FENCE REQUIREMENT NOTED CONSTRUCTION FENCE DEFECTIVE AT HESTER ST(PANELS) APPROX 4 HANGING ON TO A NAIL... $800 $0 Dec 10, 2009
Mar 9, 2009 34759119M RESOLVE CLASS - 2 SEC. 3313.1 USE & STORAGE OF ALL VOLATILE FLAMMABLE & COMBUSTIBLE MIXTURES,COMPRESSED GASES - NOTE: AT CELLAR LEVEL W... $4,000 $0 May 27, 2010
Jan 28, 2009 34750436P RESOLVE CLASS - 2 NO WATCH PERSON. UPON INSPECTION CONST OPERATION NOT IN PROGRESS NO WATCH PERSON ON SITE. REMEDY: PROVIDE WATCH PERON... $400 $0 Mar 19, 2009
Dec 24, 2008 34750296M RESOLVE CLASS - 2 SEC BC1001.4 & 27-357 FAILURE TO PROVIDE REQUIRED MEANS OF EGRESS AS NOTED AT TIME OF INSP AT ABOVE ACTIVE CONSTRUCTI... $4,000 $0 Jun 24, 2010
Dec 4, 2008 34740814Y RESOLVE CLASS - 1 FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. NOTED: AT TIME OF INSPECTION CRACKS ... $12,000 $0 Apr 1, 2010
Sep 30, 2008 34706107X RESOLVE CLASS - 1 UNLAWFULLY CONTINUED WORK WHILE ON NOTICE OF A SWO. AT TIME OF INSP. MEN WERE PUTTING UP FROM WORK AT CELLAR LEVEL OF... $4,800 $0 Aug 19, 2010
Sep 10, 2008 34706048P RESOLVE CLASS - 1 FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTION OPERATION -UPON INSPECTION EXCAVATION,FOUNDATI... $12,000 $0 Oct 15, 2009
Sep 10, 2008 34706049R RESOLVE CLASS - 1 FAILURE TO PROVIDE PROTECTION AT SIDES OF EXCAVATION UPON INSPECTION FOUNDATION AND EXCAVATION WORK FOR NB IS IN PROG... $12,000 $0 Oct 15, 2009