ECB violations
130 Hester Street, Manhattan • Block 00303 • Lot 0015
125 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jan 20, 2010 | 34833151P | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS.NOTED AT TIME OF INSPECTION FORMING 1... | $1,600 | $0 | Aug 5, 2010 |
| Jan 20, 2010 | 34833153Z | RESOLVE | CLASS - 1 | RESHORES WITHIN 10FT OF BLDG EDGE ARE SECURED,BANDED & TIED TO STRUCTURE.NOTED:AT TIME OF INSPECTION RESHORES ON FLOO... | $1,600 | $0 | Aug 5, 2010 |
| Jan 20, 2010 | 34833155M | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS.NOTED:AT TIME OF INSPECTION ON AC... | $0 | $0 | Mar 11, 2010 |
| Jan 20, 2010 | 34833154K | RESOLVE | CLASS - 2 | SEC.BC28-105.12.8.WORK IS NOT IN ACCORDANCE W/SITE SAFETY PLAN.SITE SAFETY PLAN NEEDS TO BE UPDATED SHOWING ALL CHANG... | $0 | $0 | Mar 11, 2010 |
| Jan 20, 2010 | 34826773Y | RESOLVE | CLASS - 2 | FAILURE TO POST DOT PERMIT FOR STREET/SIDEWALK CLOSING.NOTED AT TIME OF INSPECTION ALL 3 COPIES OF DOT PERMITS WERE N... | $0 | $0 | Mar 11, 2010 |
| Jan 20, 2010 | 34826771K | RESOLVE | CLASS - 2 | SEC.BC3301.9.REQUIRED SIGNS.THE SIGNS REQUIRED SHALL BE CONSTRUCTED OF3/4 INCH PLYWOOD OR SHEET METAL.THE LETTERS ON ... | $0 | $0 | Mar 11, 2010 |
| Jan 20, 2010 | 34826770Z | RESOLVE | CLASS - 2 | SEC.BC3307.8.STANDARD GUARD RAIL. STANDARD GUARDRAIL SHALL CONSIST OF A 2INCH X 4INCH WOOD TOP RAIL OR EQUIVALENT CAP... | $0 | $0 | Mar 11, 2010 |
| Jan 20, 2010 | 34826765Y | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS.NOTED:AT TIME OF INSPECTION ON ACTIVE CONSTRUCTION... | $0 | $0 | Mar 11, 2010 |
| Jan 20, 2010 | 34826764M | RESOLVE | CLASS - 2 | SEC.BC3301.2.FAILURE TO INSTITUTE & MAINTAIN SAFETY EQUIPMENT MEASURESOR TEMP CONSTRUCTION HOLES IN FL.NOTED:AT TIME ... | $0 | $0 | Mar 11, 2010 |
| Jan 20, 2010 | 34826761R | RESOLVE | CLASS - 2 | JOB SITE FENCE NOT CONSTRUCTED PURSUANT TO SUBSECTION.NOTED AT TIME OFINSPECTION 8FT CONSTRUCTION FENCE NOT BUILT SOL... | $0 | $0 | Mar 11, 2010 |
| Jan 20, 2010 | 34826760P | RESOLVE | CLASS - 2 | SEC.BC3301.9. FOLLOWING THE RECEIPT OF A PERMIT TO ERECT A MATERIAL ORPERSONAL HOIST THE PERMIT HOLDER SHALL POST A S... | $0 | $0 | Mar 11, 2010 |
| Dec 21, 2009 | 34786141M | RESOLVE | CLASS - 2 | 3306.12.FAILURE TO PROVIDE ELEVATOR INREADYNESS AT THE TIME OF MY INSPECTION.STRUCTURE UPTO 11 FL ELEVATOR/HOIST IS N... | $0 | $0 | Feb 11, 2010 |
| Dec 16, 2009 | 34786134Y | RESOLVE | CLASS - 1 | SEC. 3303.8 FAILURE TO PROVIDE STANDPIPE AT REQUIRED HEIGHT. @ THE TIME OF MY INSPECTION APPROX 23 WORKER ON SITE. BL... | $1,600 | $0 | Jun 17, 2010 |
| Dec 16, 2009 | 34786135X | RESOLVE | CLASS - 1 | SEC. 3308.1.3 FAILURE TO JUMP HORIZONTAL NETS AT THE REQUIRED HIGH ALLOWED BY CODE. @THE TIME OF MY INSPECTION APPROX... | $1,600 | $0 | Jun 17, 2010 |
| Dec 16, 2009 | 34786138L | RESOLVE | CLASS - 2 | SEC. 3303.1.3 FAILURE TO BUILD CONTRACTOR SHED BY FIRE RETARDANT TREATED MATERIALS. @ THE TIME OF INSPECTION APPROX 2... | $0 | $0 | Feb 4, 2010 |
| Dec 16, 2009 | 34786136H | RESOLVE | CLASS - 1 | SEC. 3301.2 HOLE / OPENING NOT COVERED. @ THE TIME OF MY INSPECTION APPROX 23 WORKERS ON SITE. I OBSERVED ON THE 6, 7... | $1,600 | $0 | Jun 17, 2010 |
| Dec 16, 2009 | 34786137J | RESOLVE | CLASS - 1 | SEC. 3308.3 VERICAL SAFETY NETTING MISSING. @ THE TIME OF MY INSPECTION. APPROX 23 WORKERS ON SITE. STRUCTURAL UP TO ... | $1,600 | $0 | Jun 17, 2010 |
| Nov 21, 2009 | 34786125M | RESOLVE | CLASS - 2 | FAIL TO POST PERMIT FOR WRK @ PREMISES @ THE TIME OF MY INSP WRK IN PROGRESS APPROX 15 WRK MEN ON SITE FORMING 9 FLR.... | $400 | $0 | Jul 15, 2010 |
| Nov 17, 2009 | 34786206Y | RESOLVE | CLASS - 2 | SEC. 1905.632. FAILURE TO PROVIDE CURING BOX. NOTED: AT THE TIME OF INSP RESPONDENT NAME ABOVE FAILED TO PROVIDE TEST... | $400 | $0 | Jun 3, 2010 |
| Nov 17, 2009 | 34786208H | RESOLVE | CLASS - 2 | SEC. 1RCNY5-02(A)(B). FAILURE TO PROVIDE EMPLOYEE W/PHOTO ID. NOTED: @THE TIME OF INSPECTION TECH ROMMELL L. VELEZ #0... | $0 | $0 | Jan 7, 2010 |
| Nov 17, 2009 | 34786118Y | RESOLVE | CLASS - 2 | FAIL TO SAFEGUARD ALL PERSONS/PROPERTY AFFECTED BY CONST OPERATIONS. AT THE TIME OF INSPECTION APPROX 30 WORK MEN ON ... | $1,200 | $0 | Jun 3, 2010 |
| Nov 17, 2009 | 34786117M | RESOLVE | CLASS - 2 | SEC 3301.10 MISC VIOL: OBSCURED LAWFUL SIGNS. AT THE TIME OF INSPECTION APPROX 30 WORK MEN ON SITE STRUCTURAL UP TO T... | $0 | $0 | Jan 7, 2010 |
| Nov 17, 2009 | 34786116K | RESOLVE | CLASS - 2 | FAIL TO INSTITUTE MAINTAIN SAFETY EQUIPMENT MEASURES. AT THE TIME OF INSP CONST SITE STRUCTURAL UP TO 8 FL APPROX 30 ... | $0 | $0 | Jan 7, 2010 |
| Nov 17, 2009 | 34786207X | RESOLVE | CLASS - 2 | SEC. 1RCNY5-02(A)(B). FAILURE TO PROVIDE EMPLOYEE W/PHOTO ID. NOTED: @THE TIME OF INSPECTION TECH ROMMELL L. VELEZ #0... | $0 | $0 | Jan 7, 2010 |
| Aug 31, 2009 | 34805862N | RESOLVE | CLASS - 2 | SEC. BC 3301.7 FAILURE TO PROVIDE DESIGN DRAWING FOR SAFETY STRAPS. NOTE: AT TIME OF INSPECTION AT ABOVE SITE. BUILDI... | $0 | $0 | Oct 22, 2009 |
| Aug 31, 2009 | 34805864R | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS. NOTE: AT TIME OF INSPECTION AT A... | $250 | $0 | Mar 25, 2010 |
| Aug 31, 2009 | 34805863P | RESOLVE | CLASS - 2 | SEC. 28-103.8 MATTERS NOT PROVIDED FOR. NOTE: AT TIME OF INSPECTION AT ABOVE SITE. BUILDING UP TO 6TH FLR,OBSERVED TH... | $0 | $0 | Oct 22, 2009 |
| Aug 5, 2009 | 34799299P | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. NOTED: DUE TO CONSTRUCTION OPERATION... | $2,400 | $0 | Feb 18, 2010 |
| Jul 28, 2009 | 38204973H | RESOLVE | CLASS - 1 | 97L11-RESP FAILED TO COMPLY WITH RULES #26.4.4 & #26.7 OF ANSI A10.4-1981.THE RESP HAS A HISTORY OF NON-COMPLIANCE WI... | $0 | $0 | Apr 7, 2011 |
| Jul 6, 2009 | 34790461N | RESOLVE | CLASS - 2 | JOB SITE FENCE NOT CONSTRUCTED PURSUANT TO SUBSECTION. AS NOTED: AT TIME OF INSPECTION ON A ACTIVE CONSTRUCTION SITE,... | $0 | $0 | Aug 27, 2009 |
| Jul 6, 2009 | 34790462P | RESOLVE | CLASS - 2 | SEC. BC 3301.7,27-1015 DESIGN. AS NOTED: AT TIME OF INSPECTION ON A ACTIVE CONSTRUCTION SITE,BUILDING UP TO 6 STORIES... | $0 | $0 | Aug 27, 2009 |
| Jul 6, 2009 | 34790460L | RESOLVE | CLASS - 1 | SEC. BC 3310.3 PLANS/SITE SAFETY NOT FILED. AS NOTED: AT TIME OF INSPECTION ON A ACTIVE CONSTRUCTION SITE,BUILDING UP... | $1,600 | $0 | Apr 29, 2010 |
| Jun 3, 2009 | 34783196X | RESOLVE | CLASS - 1 | PROVOF LAW BC3310.8.2 SITE SAFETY MANAGER/COORDINATOR FAILED TO IMMEDIATELY NOTIFY THE DOB OF CONDITION AS REQUIRED.N... | $1,600 | $0 | Jul 23, 2009 |
| Jun 3, 2009 | 34783195Y | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSON & PROPERTY AFFECT BY CONSTRUCTION OPERATIONS. NOTED: AT TIEM OF INSPECTION ON ACTIVE ... | $12,000 | $0 | Apr 2, 2010 |
| Jun 3, 2009 | 34783194M | RESOLVE | CLASS - 1 | PROVISION OF ALW 1906.6.1.2 RESHORES IN PROXIMITY OF FACADE (RESHORES WITHIN 10FT OF THE FACADE OF A BUILDING SHALL B... | $8,000 | $0 | Aug 12, 2010 |
| Jun 3, 2009 | 34783193K | RESOLVE | CLASS - 1 | FAILURE TO INSTITUTE & MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION (NO TOE BOARDS) NOTED: AT TIME OF... | $1,000 | $0 | Aug 12, 2010 |
| Jun 3, 2009 | 34783192Z | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSON AND PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. NOTED: AT TIME OF INSPECTION ON ACT... | $12,000 | $0 | May 27, 2010 |
| Mar 20, 2009 | 34778602X | RESOLVE | CLASS - 1 | SEC 27-157 28-104.7.1 UNDERPINNING PLANS ARE NOT ADEQUATE IN THAT PLANS ARE NOT COMPLETE & OF SUFFICIENT CLARITY TO I... | $0 | $0 | Jul 21, 2011 |
| Mar 20, 2009 | 34778603H | RESOLVE | CLASS - 1 | SEC 28-1704.9.1 FAILURE TO CARRY OUT CONTROLLED INSP RESPONSIBLITIES IN AN APPROPRIATE MANNER TO ENSURE WAS PROCEEDIN... | $1,600 | $0 | Jul 21, 2011 |
| Mar 20, 2009 | 346915892 | RESOLVE | CLASS - 1 | FAILURE TO CARRY OUT CONTROLLED INSPECTION RESPONSIBILITIES IN AN APPROPRIATE MANNER TO ENSURE WAS PROCEEDING SAFELY ... | $0 | $0 | May 14, 2009 |
| Mar 20, 2009 | 34691589Z | RESOLVE | CLASS - 1 | 27-132 FAILURE TO CARRY OUT CONTROLLED INSPECTION RESPONSIBILITIES IN AN APPROPRIATE MANNER TO ENSURE WAS PROCEEDING ... | $0 | $0 | Apr 1, 2010 |
| Mar 20, 2009 | 34691590X | RESOLVE | CLASS - 1 | "STOP ALL WORK". UNDERPINNING PLANS ARE NOT ADEQUATE IN THAT PLANS ARE NOT COMPLETE AND/OR SUFFICIENT CLARITY TO INDI... | $0 | $0 | Apr 12, 2010 |
| Mar 9, 2009 | 34759120J | RESOLVE | CLASS - 2 | SEC. 3304.4.3 FENCE REQUIREMENT NOTED CONSTRUCTION FENCE DEFECTIVE AT HESTER ST(PANELS) APPROX 4 HANGING ON TO A NAIL... | $800 | $0 | Dec 10, 2009 |
| Mar 9, 2009 | 34759119M | RESOLVE | CLASS - 2 | SEC. 3313.1 USE & STORAGE OF ALL VOLATILE FLAMMABLE & COMBUSTIBLE MIXTURES,COMPRESSED GASES - NOTE: AT CELLAR LEVEL W... | $4,000 | $0 | May 27, 2010 |
| Jan 28, 2009 | 34750436P | RESOLVE | CLASS - 2 | NO WATCH PERSON. UPON INSPECTION CONST OPERATION NOT IN PROGRESS NO WATCH PERSON ON SITE. REMEDY: PROVIDE WATCH PERON... | $400 | $0 | Mar 19, 2009 |
| Dec 24, 2008 | 34750296M | RESOLVE | CLASS - 2 | SEC BC1001.4 & 27-357 FAILURE TO PROVIDE REQUIRED MEANS OF EGRESS AS NOTED AT TIME OF INSP AT ABOVE ACTIVE CONSTRUCTI... | $4,000 | $0 | Jun 24, 2010 |
| Dec 4, 2008 | 34740814Y | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. NOTED: AT TIME OF INSPECTION CRACKS ... | $12,000 | $0 | Apr 1, 2010 |
| Sep 30, 2008 | 34706107X | RESOLVE | CLASS - 1 | UNLAWFULLY CONTINUED WORK WHILE ON NOTICE OF A SWO. AT TIME OF INSP. MEN WERE PUTTING UP FROM WORK AT CELLAR LEVEL OF... | $4,800 | $0 | Aug 19, 2010 |
| Sep 10, 2008 | 34706048P | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTION OPERATION -UPON INSPECTION EXCAVATION,FOUNDATI... | $12,000 | $0 | Oct 15, 2009 |
| Sep 10, 2008 | 34706049R | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE PROTECTION AT SIDES OF EXCAVATION UPON INSPECTION FOUNDATION AND EXCAVATION WORK FOR NB IS IN PROG... | $12,000 | $0 | Oct 15, 2009 |