| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Nov 21, 2024 | 39534585Y | RESOLVE | CLASS - 2 | AT TIME OF MY INSPECTION, I OBSERVED THAT INFORMATION PROJECT PANEL WAS NOT ELIGBLE.COMPLY WITH CODE | $1,250 | $0 | Jan 30, 2025 |
| Jul 11, 2024 | 39530442Z | RESOLVE | CLASS - 2 | OBSERVED 14 STORY NB WITH NO SIDEWALK SHED AT EXP#1 WHERE REQUIRED-UPPON CHECKING SITE SAFETY PLAN IT SHOWS SHED SHOU... | $1,250 | $0 | Mar 5, 2026 |
| Apr 5, 2024 | 35682341R | RESOLVE | CLASS - 2 | WORK WITHOUT A PERMIT EXPIRED PERMIT.NOTE:OBSERVED CONSTRUCTION FENCE WAS INSTALLED WITHOUT A VALID PERMIT.THE PREVIO... | $3,125 | $3,125 | Apr 24, 2025 |
| Dec 26, 2023 | 35675220P | RESOLVE | CLASS - 2 | TEMPORARY CONSTRUCTION EQUIPMENT OR INSTALLATION ON SITE EXPIRED PERMIT #1228268243-01-EQ-FN EXPIRED ON 09-15-2022. R... | $1,250 | $0 | Nov 7, 2024 |
| Aug 29, 2023 | 35670998N | RESOLVE | CLASS - 2 | TEMPORARY CONSTRUCTION EQUIPMENT OR INSTALLATION ON SITE EXPIRED PERMIT. #122826843-01-E9-FN EXPIRED ON 09-15-2022. R... | $1,250 | $1,250 | Mar 20, 2026 |
| Aug 28, 2023 | 39521083L | RESOLVE | CLASS - 2 | OBSERVED 14 STR NEW BLDG- TOPPED OFF, WITH A SIDEWALK SHED AT EXP#1. THE REQUIRED RED LIGHT MARKING THE LOCATION OF T... | $0 | $0 | Apr 5, 2024 |
| Aug 28, 2023 | 39521085P | RESOLVE | CLASS - 2 | OBSERVED A JOBSITE FENCE AT EXP#1 NOT FULLY PAINTED HUNTER GREEN DUE EXCESSIVE VANDALIZED MARKINGS THROUGHOUT, AND WI... | $1,000 | $0 | Apr 5, 2024 |
| Aug 28, 2023 | 39521084N | RESOLVE | CLASS - 2 | OBSERVED A SIDEWALK SHED AT EXP#1 WITH A LOOSE/WARPED PARAPET PANEL, CREATING A HAZARD FOR PEDESTRIANS AND/OR VEHICLE... | $2,400 | $0 | Apr 5, 2024 |
| Mar 2, 2023 | 35670727L | RESOLVE | CLASS - 2 | TEMPORARY CONSTRUCTION EQUIPMENT ONSITE-CONSTRUCTION PLYWOOD FENCE PERMIT EXPIRED.AS AT TIME OF INSPECTION ON AN ACTI... | $3,125 | $0 | May 11, 2023 |
| Mar 2, 2023 | 35670726J | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN/DISPLAY ONSITE DOCUMENTS REQUIRED BY BC CHAPTER 33AS NOTED AT TIME OF INSPECTION ON AN ACTIVE CON... | $625 | $0 | Oct 26, 2023 |
| Jun 24, 2022 | 35653739Y | RESOLVE | CLASS - 1 | FAILURE TO NOTIFY DEPT OF ACCIDENT/INCIDENT THAT RESULTED IN FATALITY OR INJURY.NOTE-WORKER WAS ON AFRAME LADDER LOST... | $0 | $0 | Dec 1, 2022 |
| Nov 1, 2021 | 35589165K | RESOLVE | CLASS - 2 | POSTING OF UNLAWFUL SIGNS INFORMATION PICTORIAL REPRESENTATION BUSINESS OR ADVERTISTING MESSAGE ON PROTECTIVE STRUCTU... | $1,250 | $1,250 | Jan 27, 2022 |
| Aug 2, 2021 | 35582701N | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN ADEQUATE GUARDRAIL AS PER CODE. AT TIME OF INSPECTION ON ACTIVE 14 STORY NB CONSTRUCTION SITE OBS... | $2,500 | $2,500 | Oct 14, 2021 |
| Aug 2, 2021 | 35582700L | RESOLVE | CLASS - 1 | BC3301.6 FAILURE TO PROVIDE DESIGN DRAWINGS FOR PLATFORM.AT TIME OF INSPECTION ON ACTIVE 14 STORY NB CONSTRUCTION SIT... | $1,250 | $1,250 | Oct 14, 2021 |
| Aug 2, 2021 | 35582702P | RESOLVE | CLASS - 2 | BC3314.4.8 FAILURE TO MAINTAIN PIPE SCAFFOLD AS PER CODE.AT TIME OF INSPECTION ON ACTIVE 14 STORY NB CONSTRUCTION SIT... | $0 | $0 | Oct 14, 2021 |
| Jun 2, 2021 | 35552714P | RESOLVE | CLASS - 2 | JOB SITE CONSTRUCTION FENCE IS NOT MAINTAINED.AT TIME OF INSPECTION OF A 14 STORY NB.OBSERVED JOB SITE CLOSED WITH NO... | $0 | $0 | Aug 19, 2021 |
| May 14, 2021 | 35548737X | RESOLVE | CLASS - 2 | BC3301.7 FAILURE TO PROVIDE APPROVED PE DETAILS/EOR NOTED:ATOI FOR ACTIVE CONST SITE@BULKHEAD LEVEL.OBSERVED:12"X12" ... | $1,250 | $1,250 | Jul 29, 2021 |
| Jan 8, 2021 | 35542437R | RESOLVE | CLASS - 1 | BC 3301.7 FAILURE TO PROVIDE APPROVED P.E DESIGN DRAWING. AS NOTED:AT TIME OF INSPECTION FOR AN ACTIVE CONSTRUCTION S... | $2,500 | $2,500 | Mar 25, 2021 |
| Jan 4, 2021 | 35539112L | RESOLVE | CLASS - 2 | BC 3314.8.2 DEBRIS NETTING. AT THE TIME OF INSPECTION ON AN ACTIVE JOBSITE CURRENTLY AT ROOF LEVEL I OBSERVED DEBRIS ... | $0 | $0 | Mar 18, 2021 |
| Jan 4, 2021 | 35539111J | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS. ATTHE TIME OF INSPECTION ON AN ACTIVE JOB SITE CU... | $0 | $0 | Mar 18, 2021 |
| Sep 1, 2020 | 35503335Y | RESOLVE | CLASS - 2 | SEC. 3301.2 SAFETY MEASURES & STANDARS. ATTHE TIME OF AN INSPECTION OFA NEW BLDG UNDER CONSTRUCTION,I OBSERVED LOTS O... | $0 | $0 | Nov 12, 2020 |
| Sep 1, 2020 | 35503334M | RESOLVE | CLASS - 2 | SEC. 3308.6 INADEQUATE NETTINGS. AT THE TIME OF AN INSPECTION OF A NEWBLDG UNDER CONSTRUCTION,I OBSERVED INADEQUATE N... | $0 | $0 | Nov 12, 2020 |
| Jun 29, 2020 | 35464498J | RESOLVE | CLASS - 1 | 3307.4.3 UDOCKS/BARRIERS NOT FILLED/VEHICULAR TRAFFIC.AT THE TIME OF INSPECTION I OBSERVE ACTIVE JOBSITE WITH CONSTRU... | $2,500 | $0 | Sep 3, 2020 |
| Jun 29, 2020 | 35464499L | RESOLVE | CLASS - 2 | FAILURE TO SAFEGUARD/FAILURE MAINTAINED SAFETY OPERATIONS.AT THE TIME OF INSPECTION I OBSERVE ACTIVE CONSTRUCTION JOB... | $5,000 | $0 | Sep 3, 2020 |
| Jun 29, 2020 | 35464497H | RESOLVE | CLASS - 1 | FAILURE TO MAINTAINED RECORDS OF PRF-SHIFT SAFETY MEETING FOR EACH WORKER.AT THE TIME OF INSPECTION I OBSERVE ACTIVE ... | $2,500 | $0 | Sep 3, 2020 |
| Mar 17, 2020 | 35472146X | RESOLVE | CLASS - 1 | WORK CONTRARY TO STOP WORK ORDER AT THE TIME OF MY INSPECTION RESPONDING TO COMPLAINT#1538934,I OBSERVED HOIST WORKIN... | $5,000 | $0 | Feb 25, 2021 |
| Mar 16, 2020 | 35469157Y | RESOLVE | CLASS - 1 | BC330910-PROTECTOIN OF ROOF/OVERHEAD.NOTE:AT THE TIME OF MY INSPECTIONOF AN ACTIVE JOB SITE 14 STORY NEW BUILDING I O... | $2,500 | $0 | Feb 25, 2021 |
| Mar 16, 2020 | 35469158X | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS.NOTE:AT THE TIME OF INSPECTION I ... | $625 | $0 | Feb 25, 2021 |
| Mar 16, 2020 | 35469156M | RESOLVE | CLASS - 1 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND OR APPROVED AMENDMENTS.AT THE TIME OF INSPECTION I OBSER... | $625 | $0 | Feb 25, 2021 |
| Nov 1, 2019 | 35462070J | RESOLVE | CLASS - 2 | BC 3301.2 FAILURE TO INSTITTUTE/MAINTAIN SAFETY MEASURES @TIME OF INSPECTION OF A 14 STY BUILDING UNDER CONST I OBSER... | $0 | $0 | Jan 9, 2020 |
| Nov 1, 2019 | 35462066R | RESOLVE | CLASS - 2 | BC33086-FAILURE TO OR MAINTAIN HORIZONTAL SAFETY NETTING WHERE REQUIRED.AT TIME OF INSPECTION OF A 14 STORY NEW BUILD... | $0 | $0 | Jan 9, 2020 |
| Nov 1, 2019 | 35462073P | RESOLVE | CLASS - 1 | BC33012-FAILURE TO INSTITUTE/MAINTAIN SAFETY MEASURES.AT TIME OF INSPECTION OF A 14 STORY BUILDING UNDER CONSTRUCTION... | $2,500 | $0 | Jan 9, 2020 |
| Nov 1, 2019 | 35462072N | RESOLVE | CLASS - 1 | BC 3307.6 SIDEWALK SHED NNOT CONSTRUCTED/MAINTAINED AS REQUIRED. @TIMEOF INSPECTION OF A 14 STY NEW BUILDING UNDER CO... | $625 | $0 | Jan 9, 2020 |
| Nov 1, 2019 | 35462068K | RESOLVE | CLASS - 1 | BC 3301.2 FAILURE TO MAINTAIN SAFETY MEASURES @TIME OF INSPECTION OF AA 14 STY BUILDING UNDER CONST, I OBSERVED THAT ... | $2,500 | $0 | Jan 9, 2020 |
| Nov 1, 2019 | 35462069M | RESOLVE | CLASS - 1 | 28-301.1 FAILURE TO COMPLY WITH DOB HIGH WINDS ADVISORY. @TIME OF INSPECTION OF A 14 STY BUILDING UNDER CONST I OBSER... | $2,500 | $0 | Jan 9, 2020 |
| Nov 1, 2019 | 35462067Z | RESOLVE | CLASS - 1 | FAILURE TO PERFORM TO SUCCESSFULL HYDROSTATTIC PRESSURE TEST OF STANDPIPE SYSTEM. @TIME OF INSPECTION OF A 14 STY NEW... | $5,000 | $0 | Jan 9, 2020 |
| Nov 1, 2019 | 35462071L | RESOLVE | CLASS - 2 | JOB SITE FENCE NOT CONSTRUCTED OR MAINTAINED PURSUANT TO SUBSECTION. @TIME OF INSPECTION OF A 14 STY BUILDING UNDER C... | $0 | $0 | Jan 9, 2020 |
| May 30, 2019 | 35422914Y | RESOLVE | CLASS - 1 | HOUSEKEEPING. AT TIME OF INSPECTION I OBSERVED SLIP/TRIP HAZARDS AT THE CELLAR, 1ST, 4,5,6,AND 7TH FLOORS. THIS IS A ... | $2,500 | $0 | Oct 10, 2019 |
| May 30, 2019 | 35422912K | RESOLVE | CLASS - 1 | INADEQUATE GUARDRAILS. AT TIME OF INSPECTION I OBSERVED INADEQUATE GUARDRAILS AT THE PERIMETER OF THE SITE AT MULTIPL... | $2,500 | $0 | Oct 10, 2019 |
| May 30, 2019 | 35422908H | RESOLVE | CLASS - 1 | WORK NOT TO SITE SAFETY PLAN ON SITE. AT TIME OF INSPECTION ON AN ACTIVE CONSTRUCTION SITE, NOTICE THAT DOT APPROVE B... | $1,250 | $0 | Oct 10, 2019 |
| May 30, 2019 | 35422913M | RESOLVE | CLASS - 1 | WORK NOT CONFORMING TO APPROVE CONSTRUCTION DOCUMETNS. SIDEWALK SHED. AT TIME OF INSPECTION ON AN ACTIVE CONSTRUCTION... | $625 | $0 | Oct 10, 2019 |
| May 30, 2019 | 35422911Z | RESOLVE | CLASS - 1 | GAPS/HOLES/OPENINGS UNPROTECTED OR INADEQUATE PROTECTION AT FLOORS, MULTIPLE LEVELS. AT TIME OF INSPECTION I OBSERVED... | $10,000 | $0 | Oct 10, 2019 |
| May 30, 2019 | 35422910R | RESOLVE | CLASS - 1 | 3305.3.4 WORK NOT TO APPROVE DRAWINGS ON CONSTRUCTION SITE. AT TIME OF INSPECTION ON AN ACTIVE CONSTRUCTION SITE 14 S... | $2,500 | $0 | Oct 10, 2019 |
| May 30, 2019 | 35422909J | RESOLVE | CLASS - 2 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTIONOPERATIONS. AT TIME OF INSPECTION ON AN ACTIVE ... | $5,000 | $0 | Oct 10, 2019 |
| Oct 10, 2018 | 35351254M | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE APPROVED /ACCEPTED CONSTRUCTION DOCUMENTS.AT THE TIME OF INSPECTION. AT TIME OF INSPECTION IT WAS ... | $0 | $0 | Dec 6, 2018 |
| Oct 10, 2018 | 35351255Y | RESOLVE | CLASS - 2 | 3307.3.2 FAILURE TO PROVIDE LOT LINE FENCE. AT THE TIME OF INSEPCTION OBSERVED NO CONSTRUCTION FENCE INSTALLED AT EXP... | $0 | $0 | Dec 6, 2018 |
| Jul 18, 2018 | 35345102M | RESOLVE | CLASS - 1 | SEC. 3310.5.2 SITE SAFETY NOT PRESENT. AT TIME OF INSPECTION OF A 14 STY BLDG,CURRENTLY ON THE FOUNDATION PHASE I OBS... | $10,000 | $0 | Sep 6, 2018 |