ECB violations
356 East 8 Street, Manhattan • Block 00377 • Lot 0010
35 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Feb 6, 2025 | 39536760L | RESOLVE | CLASS - 1 | 3301.5-UNSAFE CONDITIONS. PARK ACCESS AGREEMENT WAS BETWEEN THE PARK AND SWS PERMIT HOLDER (NURUL AMIN) INSTEAD OF SU... | $5,000 | $5,000 | Dec 17, 2026 |
| Feb 6, 2025 | 39536755R | RESOLVE | CLASS - 1 | I POST A PARTIAL STOP WORK ORDER ON 2/5/2025 HOWEVER WHEN I CAME BACK ON THE NEXT DAY(2/6/2025) I OBSERVE THAT THE PO... | $2,500 | $2,500 | Dec 17, 2026 |
| Feb 5, 2025 | 39536695Y | RESOLVE | CLASS - 1 | OBSERVED SHORING AT 1ST FLOOR MISSING POST AT MULTIPLE C JOIST, INCORRECT X-BRACING. MISSING SHORING AT CELLAR LEVEL.... | $2,500 | $2,500 | Dec 17, 2026 |
| Feb 5, 2025 | 39536680L | RESOLVE | CLASS - 1 | ACTIVE ALT. OBSRERVED TEMP. SHORING W/ MULTIPLE POSTS REMOVED FOR STRUCTURAL SUPPORT @ CELLAR &1ST FL, NO REVISED AUD... | $10,000 | $10,000 | Dec 17, 2026 |
| Feb 5, 2025 | 39536690P | RESOLVE | CLASS - 1 | ACTIVE JOBSITE UNDER ALTERATION OBSERVED SIDEWALKS SHED W/ POSTS & BRACES CONTRARY TO PLANS W/ PIPE SCAFFOLD TOP OF D... | $5,000 | $5,000 | Dec 17, 2026 |
| Feb 5, 2025 | 39536693K | RESOLVE | CLASS - 2 | OBSERVED AN ACTIVE JOB SITE MISSING CONSTRUCTION FENCE AT EXP.#2,3&4 AS PER 3307.7 WHERE REQUIRED FENCE WHEN BUILDING... | $1,000 | $1,000 | Dec 17, 2026 |
| Feb 5, 2025 | 39536698J | RESOLVE | CLASS - 1 | 3303.2.3-OBSERVED AN ACTIVE ELECTRICAL PANEL ON CELLAR LEVEL WHICH EXPOSE ALL WORKERS TO ELECTRICAL HAZARD.STOP ALL W... | $5,000 | $5,000 | Dec 17, 2026 |
| Feb 5, 2025 | 39536697H | RESOLVE | CLASS - 1 | OBSERVED DEBRIS & STORED MATERIALS ON FIRST FLOOR&CELLAR WHICH MUST BE REMOVED DAILY. ALSO OBSERVED GASOLINE TANK STO... | $2,500 | $2,500 | Dec 17, 2026 |
| Feb 5, 2025 | 39536696X | RESOLVE | CLASS - 1 | 3301.6.1&3305.8.7-OBSERVED MATERIALS WERE STORED ON FIRST FLOOR ON A RESTRICTED AREA. THIS WRONGFUL PLACEMENT OVERLOA... | $5,000 | $5,000 | Dec 17, 2026 |
| Dec 18, 2024 | 39133254M | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION, NOTED AN UNCOVERED DEBRIS CONTAINER, W/ SHARP CONC, WOOD AND OTHER DEBRIS PILED ABOVE, ADJ THE... | $5,000 | $5,000 | Dec 29, 2025 |
| Dec 13, 2023 | 39101421Y | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. BUILDING IS IN FULL STATE OF DISREPAIR WITH NO ROOF PRESENT AN... | $3,125 | $3,125 | Feb 22, 2024 |
| Aug 8, 2022 | 39067582Z | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. NOTE: AT TIME OF INSPECTION, OBSERVED EXTERIOR WALL IN A HAZAR... | $1,250 | $0 | Sep 22, 2022 |
| Nov 19, 2018 | 39000795X | RESOLVE | CLASS - 2 | JOB SITE FENCE NOT MAINTAINED PURSUANT TO SUBSECTION. NOTED CONSTRUCTION FENCE IN DISREPAIR WITH LEANING PANELS AND H... | $0 | $0 | Jan 3, 2019 |
| Apr 9, 2018 | 37009682H | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #35246916H ISSUED ON 7/21/17, AND TO FILE ... | $6,250 | $0 | Jun 21, 2018 |
| Apr 4, 2018 | 35286073P | RESOLVE | CLASS - 2 | TEMPORARY CONSTRUCTION EQUIPMENT ON SITE: EXP PERMIT. NOTE: AT TIME OF INSPECTION I OBSERVED SIDEWALK SHED ON SITE W/... | $3,125 | $0 | May 24, 2018 |
| Apr 4, 2018 | 35286074R | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE SIDEWALK SHED JOBSITE SIGN. NOTE: AT TIME OF INSPECTION I OBSERVED SIDEWALK SHED W/O A PARAPET PAN... | $6,250 | $0 | May 24, 2018 |
| Jan 5, 2018 | 35310581Z | RESOLVE | CLASS - 2 | FAILURE TO CERTIFY CORRECTION. THE RESPONDENT FAILED TO COMPLY WITH AN ORDER OF THE COMMISSIONER ISSUED PURSUANT TO S... | $4,000 | $0 | Mar 22, 2018 |
| Oct 31, 2017 | 35288539R | RESOLVE | CLASS - 2 | FAILURE TO CERTIFY CORRECTION. THE RESPONDENT FAILED TO COMPLY WITH AN ORDER OF THE COMMISSIONER ISSUED PURSUANT TO S... | $4,000 | $0 | Apr 5, 2018 |
| Aug 17, 2017 | 35269833Y | RESOLVE | CLASS - 1 | THE RESPONDENT FAILED TO COMPLY WITH THE AN ORDER OF THE DOB ISSUED THROUGH DOB CONTORL #280118, VIOLATION #072117ID1... | $0 | $0 | Mar 15, 2018 |
| Aug 17, 2017 | 35287942M | RESOLVE | CLASS - 1 | THE RESPONDENT FAILED TO COMPLY WITH AN ORDER OF THE DOB ISSUED THROUGH DOB CONTROL#280118,VIOLATION#07211 ID10301IG,... | $12,000 | $0 | Jan 18, 2018 |
| Jul 21, 2017 | 35246916H | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN THE RESPONDENT FAILED TO MAINTAIN THE BUILDING A PRIOR STALLED ALTERATION (JOB#121330390). THERE ... | $500 | $0 | Sep 14, 2017 |
| Dec 24, 2015 | 35155957K | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION. AT THE TIME OF INSPECTION OBSERVED THAT GASOLIN... | $0 | $0 | Apr 7, 2016 |
| Dec 24, 2015 | 35155952L | RESOLVE | CLASS - 2 | SEC. 3307.7 FAILURE TO PROVIDE AN ADEQUATE CONSTRUCTION FENCE. JOBSITEFENCE HAS NO VIEW PANEL,FENCE DOES NOT MEET DOB... | $0 | $0 | Feb 11, 2016 |
| Dec 24, 2015 | 35155959Y | RESOLVE | CLASS - 1 | SEC. 28-116.2.3 DESIGNATED CONTROLLED INSPECTOR INSPECTOR(SPECIAL INSPECTION)HAS NOT ADEQUATELY PERFORMED INSPECTION ... | $0 | $0 | Apr 28, 2016 |
| Dec 24, 2015 | 35155955R | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE APPROVED/ACCEPTED PLANS AT THE JOBSITE. THE RESPONDENT FAILED TO PROVIDE APPROVED PLANS FOR TEMPOR... | $0 | $0 | Feb 11, 2016 |
| Dec 24, 2015 | 35155958M | RESOLVE | CLASS - 2 | SEC. 3303.2.4 FAILURE TO PROVIDE THE REQUIRE TEMPORARY OR PERMANENT SANITARY FACILITIES DURING CONSTRUCTION OPERATION... | $0 | $0 | Feb 11, 2016 |
| Dec 24, 2015 | 35155956Z | RESOLVE | CLASS - 1 | FAILURE TO MIANTIAN ADEQUATE HOUSEKEEPING: CONSTRUCTION MATERIAL & DEBRIS NOT PROPERLY STORED OR REMOVED FROM THE JOB... | $400 | $0 | Apr 7, 2016 |
| Dec 24, 2015 | 35155960L | RESOLVE | CLASS - 2 | SEC. 1704.1.1 FAILURE TO FILE A SPECIAL INSPECTION STATEMENT OF RESPONSIBILITY PRIOR TO PERMIT ISSUANCE & PRIOR TO TH... | $0 | $0 | Feb 11, 2016 |
| Dec 24, 2015 | 35155951J | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. THE RESPONDENT FAILED TO ENSURE THAT... | $2,400 | $0 | May 24, 2016 |
| Dec 24, 2015 | 35155953N | RESOLVE | CLASS - 1 | SEC. 3306.4 FAILURE TO PROPERLY SORE & BRACE A WEAKENED STRUCTURE PRIOR TO FULL OR PARTIAL DEMOLITION. THE RESPONDENT... | $1,600 | $0 | May 24, 2016 |
| Dec 24, 2015 | 35155954P | RESOLVE | CLASS - 1 | FAILURE TO NOTIFY THE DOB W/I 24 TO 48HRS OF THE START OF EXCAVATION. EXCAVATION WAS DONE FOR THE CONSTRUCTION OF FOO... | $0 | $0 | May 19, 2016 |
| Dec 22, 2014 | 34999193N | RESOLVE | CLASS - 2 | 1704.1.1,FAILURE TO FILE A SPECIAL STATEMENT OF INSP OF RESPONSIBILITYPRIOR TO PERMIT ISSUANCE & PRIOR TO START OF WO... | $0 | $0 | Feb 5, 2015 |
| Sep 24, 2007 | 34593950L | RESOLVE | Hazardous | EXIT PASSAGEWAY OR EGRESS TOTAL OBSTRUCTION. NOTED: AT THE TIME OF INSPECTION I FOUND THAT ON THE REAR OF THE HOUSE T... | $480 | $0 | Apr 10, 2008 |
| Sep 5, 2007 | 34593564N | RESOLVE | Non-Hazardous | WORK W/O A PERMIT. NOTED: A FULL DECK W/ RAILINGS AND STEPS HAS BEEN INSTALLED IN THE REAR YARD APPROX 350 SQ FT.REME... | $500 | $0 | Oct 25, 2007 |
| Jun 6, 2007 | 34579819P | RESOLVE | Non-Hazardous | WORK W/O PERMIT. NOTED: ROOF DECK ACCESSIBLE FROM 2ND FL CONSTRUCTED OF STOCKADE FENCING RESTING ON 2 X 4 SLEEPERS, 1... | $250 | $0 | Jul 26, 2007 |