Skip to content

ECB violations

356 East 8 Street, Manhattan • Block 00377 • Lot 0010

35 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Feb 6, 2025 39536760L RESOLVE CLASS - 1 3301.5-UNSAFE CONDITIONS. PARK ACCESS AGREEMENT WAS BETWEEN THE PARK AND SWS PERMIT HOLDER (NURUL AMIN) INSTEAD OF SU... $5,000 $5,000 Dec 17, 2026
Feb 6, 2025 39536755R RESOLVE CLASS - 1 I POST A PARTIAL STOP WORK ORDER ON 2/5/2025 HOWEVER WHEN I CAME BACK ON THE NEXT DAY(2/6/2025) I OBSERVE THAT THE PO... $2,500 $2,500 Dec 17, 2026
Feb 5, 2025 39536695Y RESOLVE CLASS - 1 OBSERVED SHORING AT 1ST FLOOR MISSING POST AT MULTIPLE C JOIST, INCORRECT X-BRACING. MISSING SHORING AT CELLAR LEVEL.... $2,500 $2,500 Dec 17, 2026
Feb 5, 2025 39536680L RESOLVE CLASS - 1 ACTIVE ALT. OBSRERVED TEMP. SHORING W/ MULTIPLE POSTS REMOVED FOR STRUCTURAL SUPPORT @ CELLAR &1ST FL, NO REVISED AUD... $10,000 $10,000 Dec 17, 2026
Feb 5, 2025 39536690P RESOLVE CLASS - 1 ACTIVE JOBSITE UNDER ALTERATION OBSERVED SIDEWALKS SHED W/ POSTS & BRACES CONTRARY TO PLANS W/ PIPE SCAFFOLD TOP OF D... $5,000 $5,000 Dec 17, 2026
Feb 5, 2025 39536693K RESOLVE CLASS - 2 OBSERVED AN ACTIVE JOB SITE MISSING CONSTRUCTION FENCE AT EXP.#2,3&4 AS PER 3307.7 WHERE REQUIRED FENCE WHEN BUILDING... $1,000 $1,000 Dec 17, 2026
Feb 5, 2025 39536698J RESOLVE CLASS - 1 3303.2.3-OBSERVED AN ACTIVE ELECTRICAL PANEL ON CELLAR LEVEL WHICH EXPOSE ALL WORKERS TO ELECTRICAL HAZARD.STOP ALL W... $5,000 $5,000 Dec 17, 2026
Feb 5, 2025 39536697H RESOLVE CLASS - 1 OBSERVED DEBRIS & STORED MATERIALS ON FIRST FLOOR&CELLAR WHICH MUST BE REMOVED DAILY. ALSO OBSERVED GASOLINE TANK STO... $2,500 $2,500 Dec 17, 2026
Feb 5, 2025 39536696X RESOLVE CLASS - 1 3301.6.1&3305.8.7-OBSERVED MATERIALS WERE STORED ON FIRST FLOOR ON A RESTRICTED AREA. THIS WRONGFUL PLACEMENT OVERLOA... $5,000 $5,000 Dec 17, 2026
Dec 18, 2024 39133254M RESOLVE CLASS - 2 AT TIME OF INSPECTION, NOTED AN UNCOVERED DEBRIS CONTAINER, W/ SHARP CONC, WOOD AND OTHER DEBRIS PILED ABOVE, ADJ THE... $5,000 $5,000 Dec 29, 2025
Dec 13, 2023 39101421Y RESOLVE CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. BUILDING IS IN FULL STATE OF DISREPAIR WITH NO ROOF PRESENT AN... $3,125 $3,125 Feb 22, 2024
Aug 8, 2022 39067582Z RESOLVE CLASS - 2 FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. NOTE: AT TIME OF INSPECTION, OBSERVED EXTERIOR WALL IN A HAZAR... $1,250 $0 Sep 22, 2022
Nov 19, 2018 39000795X RESOLVE CLASS - 2 JOB SITE FENCE NOT MAINTAINED PURSUANT TO SUBSECTION. NOTED CONSTRUCTION FENCE IN DISREPAIR WITH LEANING PANELS AND H... $0 $0 Jan 3, 2019
Apr 9, 2018 37009682H RESOLVE CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #35246916H ISSUED ON 7/21/17, AND TO FILE ... $6,250 $0 Jun 21, 2018
Apr 4, 2018 35286073P RESOLVE CLASS - 2 TEMPORARY CONSTRUCTION EQUIPMENT ON SITE: EXP PERMIT. NOTE: AT TIME OF INSPECTION I OBSERVED SIDEWALK SHED ON SITE W/... $3,125 $0 May 24, 2018
Apr 4, 2018 35286074R RESOLVE CLASS - 2 FAILURE TO PROVIDE SIDEWALK SHED JOBSITE SIGN. NOTE: AT TIME OF INSPECTION I OBSERVED SIDEWALK SHED W/O A PARAPET PAN... $6,250 $0 May 24, 2018
Jan 5, 2018 35310581Z RESOLVE CLASS - 2 FAILURE TO CERTIFY CORRECTION. THE RESPONDENT FAILED TO COMPLY WITH AN ORDER OF THE COMMISSIONER ISSUED PURSUANT TO S... $4,000 $0 Mar 22, 2018
Oct 31, 2017 35288539R RESOLVE CLASS - 2 FAILURE TO CERTIFY CORRECTION. THE RESPONDENT FAILED TO COMPLY WITH AN ORDER OF THE COMMISSIONER ISSUED PURSUANT TO S... $4,000 $0 Apr 5, 2018
Aug 17, 2017 35269833Y RESOLVE CLASS - 1 THE RESPONDENT FAILED TO COMPLY WITH THE AN ORDER OF THE DOB ISSUED THROUGH DOB CONTORL #280118, VIOLATION #072117ID1... $0 $0 Mar 15, 2018
Aug 17, 2017 35287942M RESOLVE CLASS - 1 THE RESPONDENT FAILED TO COMPLY WITH AN ORDER OF THE DOB ISSUED THROUGH DOB CONTROL#280118,VIOLATION#07211 ID10301IG,... $12,000 $0 Jan 18, 2018
Jul 21, 2017 35246916H RESOLVE CLASS - 2 FAILURE TO MAINTAIN THE RESPONDENT FAILED TO MAINTAIN THE BUILDING A PRIOR STALLED ALTERATION (JOB#121330390). THERE ... $500 $0 Sep 14, 2017
Dec 24, 2015 35155957K RESOLVE CLASS - 1 FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION. AT THE TIME OF INSPECTION OBSERVED THAT GASOLIN... $0 $0 Apr 7, 2016
Dec 24, 2015 35155952L RESOLVE CLASS - 2 SEC. 3307.7 FAILURE TO PROVIDE AN ADEQUATE CONSTRUCTION FENCE. JOBSITEFENCE HAS NO VIEW PANEL,FENCE DOES NOT MEET DOB... $0 $0 Feb 11, 2016
Dec 24, 2015 35155959Y RESOLVE CLASS - 1 SEC. 28-116.2.3 DESIGNATED CONTROLLED INSPECTOR INSPECTOR(SPECIAL INSPECTION)HAS NOT ADEQUATELY PERFORMED INSPECTION ... $0 $0 Apr 28, 2016
Dec 24, 2015 35155955R RESOLVE CLASS - 2 FAILURE TO PROVIDE APPROVED/ACCEPTED PLANS AT THE JOBSITE. THE RESPONDENT FAILED TO PROVIDE APPROVED PLANS FOR TEMPOR... $0 $0 Feb 11, 2016
Dec 24, 2015 35155958M RESOLVE CLASS - 2 SEC. 3303.2.4 FAILURE TO PROVIDE THE REQUIRE TEMPORARY OR PERMANENT SANITARY FACILITIES DURING CONSTRUCTION OPERATION... $0 $0 Feb 11, 2016
Dec 24, 2015 35155956Z RESOLVE CLASS - 1 FAILURE TO MIANTIAN ADEQUATE HOUSEKEEPING: CONSTRUCTION MATERIAL & DEBRIS NOT PROPERLY STORED OR REMOVED FROM THE JOB... $400 $0 Apr 7, 2016
Dec 24, 2015 35155960L RESOLVE CLASS - 2 SEC. 1704.1.1 FAILURE TO FILE A SPECIAL INSPECTION STATEMENT OF RESPONSIBILITY PRIOR TO PERMIT ISSUANCE & PRIOR TO TH... $0 $0 Feb 11, 2016
Dec 24, 2015 35155951J RESOLVE CLASS - 1 FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. THE RESPONDENT FAILED TO ENSURE THAT... $2,400 $0 May 24, 2016
Dec 24, 2015 35155953N RESOLVE CLASS - 1 SEC. 3306.4 FAILURE TO PROPERLY SORE & BRACE A WEAKENED STRUCTURE PRIOR TO FULL OR PARTIAL DEMOLITION. THE RESPONDENT... $1,600 $0 May 24, 2016
Dec 24, 2015 35155954P RESOLVE CLASS - 1 FAILURE TO NOTIFY THE DOB W/I 24 TO 48HRS OF THE START OF EXCAVATION. EXCAVATION WAS DONE FOR THE CONSTRUCTION OF FOO... $0 $0 May 19, 2016
Dec 22, 2014 34999193N RESOLVE CLASS - 2 1704.1.1,FAILURE TO FILE A SPECIAL STATEMENT OF INSP OF RESPONSIBILITYPRIOR TO PERMIT ISSUANCE & PRIOR TO START OF WO... $0 $0 Feb 5, 2015
Sep 24, 2007 34593950L RESOLVE Hazardous EXIT PASSAGEWAY OR EGRESS TOTAL OBSTRUCTION. NOTED: AT THE TIME OF INSPECTION I FOUND THAT ON THE REAR OF THE HOUSE T... $480 $0 Apr 10, 2008
Sep 5, 2007 34593564N RESOLVE Non-Hazardous WORK W/O A PERMIT. NOTED: A FULL DECK W/ RAILINGS AND STEPS HAS BEEN INSTALLED IN THE REAR YARD APPROX 350 SQ FT.REME... $500 $0 Oct 25, 2007
Jun 6, 2007 34579819P RESOLVE Non-Hazardous WORK W/O PERMIT. NOTED: ROOF DECK ACCESSIBLE FROM 2ND FL CONSTRUCTED OF STOCKADE FENCING RESTING ON 2 X 4 SLEEPERS, 1... $250 $0 Jul 26, 2007