ECB violations
243 East 7 Street, Manhattan • Block 00377 • Lot 0066
20 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jul 21, 2023 | 39090723Z | RESOLVE | CLASS - 1 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR AMENDMENTS. OBSERVED 4TH,5TH AND 6TH FLOOR OF ALTERAT... | $625 | $0 | Jan 25, 2024 |
| Apr 4, 2023 | 39082999J | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER-SECTION REQUIREMENTS. AT THE TIME OF INSPECTION, UNDER JOB # 121208754-... | $0 | $0 | Jun 8, 2023 |
| Apr 4, 2023 | 39083000J | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR AMENDMENTS. AT THE TIME OF INSPECTION, UNDER JOB # 12... | $625 | $0 | Nov 6, 2023 |
| May 5, 2022 | 35654141Y | RESOLVE | CLASS - 1 | BC3301.6 DESIGN & CAPACITY OF MATERIALS FOR TEMPORARY CONSTRUCTION & EQUIPMENT DESIGN DRAWINGS FOR CHAIN LINK FENCE I... | $625 | $0 | Jan 12, 2023 |
| May 5, 2022 | 35654140M | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN ON SITE DOCUMENTS ON SITE REQUIRE BY BC CHAPTER 33 STOP ALL WORK ENTIRE SITE PROVIDE FULL PRE CON... | $625 | $0 | Oct 13, 2022 |
| Nov 4, 2021 | 35632493K | RESOLVE | CLASS - 1 | BC3307.7.1 LOCATION OF FENCE.NOTE:AT TIME OF INSPECTION OF PROPOSED 6 STORY BUILDING OBSERVED MISSING CONSTRUCTION FE... | $500 | $0 | Jun 9, 2022 |
| Nov 4, 2021 | 35632495Y | RESOLVE | CLASS - 2 | BC3301.6 DESIGN.NOTE:AT TIME OF INSPECTION OF PROPOSED 6 STORY BUILDING OBSERVED CONSTRUCTION FENCE IN PLACE AT EXP #... | $0 | $0 | Feb 3, 2022 |
| Nov 4, 2021 | 35632494M | RESOLVE | CLASS - 2 | BC3307.2.6(1)REQUIREMENTS FOR SIDEWALK.NOTE:AT TIME OF INSPECTION OF PROPOSED 6 STORY BUILDING OBSERVED NO CLEAR 5FT ... | $0 | $0 | Feb 3, 2022 |
| Nov 4, 2021 | 35632492Z | RESOLVE | CLASS - 1 | BC3307.4.7 WORK OR STORAGE ZONES.NOTE:AT TIME OF INSPECTION OF PROPOSED 6 STORY BUILDING OBSERVED WORK AND STORAGE ZO... | $625 | $0 | Nov 10, 2022 |
| Aug 30, 2021 | 35583084L | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH MANUFACTURER SPECIFICATIONS AT THE TIME OF INSPECTION AT 3 STORY BUILDING,I OBSERVED JERSEY BA... | $0 | $0 | Nov 18, 2021 |
| Jun 21, 2021 | 35558635Y | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE PROJECT INFORMATION SIGNS.NOTE:@TIME OF INSP OF A 3STORY INACTIVE JOBSITE,I OBSERVED SIDEWALK SHED... | $0 | $0 | Sep 2, 2021 |
| Jun 21, 2021 | 35558636X | RESOLVE | CLASS - 2 | INADEQUATE JOBSITE FENCE(PEDESTRIAN PROTECTION)NOTE:@TIME OF INSP I OBSERVED INACTIVE JOBSITE OF A 3 STORY BLDG,CONST... | $625 | $0 | Jan 13, 2022 |
| May 11, 2021 | 35552933P | RESOLVE | CLASS - 1 | BC 3301.2 FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS(NO OVERHEAD PROTECTION OR... | $0 | $0 | Jul 29, 2021 |
| May 11, 2021 | 35552935Z | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS.AT TIME OF INPSECTION OF THIS 3 STORY BUILDING I O... | $625 | $0 | Jul 29, 2021 |
| May 11, 2021 | 35552934R | RESOLVE | CLASS - 2 | BC 3303.7.2 FIRE EXTINGUISHERS SHALL BE PROVIDED IN ACCEPTANCE WITH THE NYC FIRE CODE.AT TIME OF INSPECTION I OBSERVE... | $0 | $0 | Jul 29, 2021 |
| May 11, 2021 | 35552932N | RESOLVE | CLASS - 1 | BC 3301.13.1 INADEQUATE SITE SAFETY PLAN(DOES NOT SHOW CAZ OR OVERHEADPROTECTION FOR EXP 2 AND 4 ADJOINING PROPERTIES... | $625 | $0 | Jul 29, 2021 |
| Jun 22, 2016 | 35196615L | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG NOTED: FOUND 3RD FLR BRICK PARAPET WALL AT FRONT NEAR WINDOW LINTELS BULGING OUT. AREA APPRX... | $2,500 | $0 | Aug 11, 2016 |
| Jun 19, 2012 | 34938527P | RESOLVE | CLASS - 3 | WORK W/O A PERMIT. WORK NOTED: INSTALLED STAND UP SHOWER IN CELLAR. REMEDY: OBTAIN PERMIT & RESTORE TO PRIOR LEGAL CO... | $200 | $0 | Aug 9, 2012 |
| Jun 19, 2012 | 34938526N | RESOLVE | CLASS - 2 | OCCUPANCY CONTRARY TO THAT ALLOWED BY BUILDING DEPT RECORDS. LEGAL USE: STORAGE - CURRENT USE - 1 BEDROOM APT W/3PC B... | $1,200 | $0 | Aug 9, 2012 |
| May 6, 1998 | 34175838J | RESOLVE | Hazardous | FAILURE TO MAINTAIN BLDG EXTERIOR NOTED: AT WEST SIDE OF BLDG EXTERIORWALL THROUGHOUT ALL FLOOR LEVELS PLASTER/ STUCC... | $800 | $0 | Jun 25, 1998 |