| Issued | Violation | Type | Category | Description | Disposed |
|---|---|---|---|---|---|
| May 8, 2026 | 26-01260 | C-CONSTRUCTION OTHER OPTIONAL | V-DOB VIOLATION - ACTIVE | STRUCTURE RENDERED NON-COMPLIANT. AT TIME OF INSPECTION OBSERVED AT 3RD FLOOR, 2ND WINDOW FROM EXPOSURE 2 HAS HORIZON... | — |
| Nov 14, 2025 | 01961 | LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED | V*-DOB VIOLATION - DISMISSED | VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Dec 30, 2025 |
| Apr 29, 2024 | FEU10302XC | C-CONSTRUCTION OTHER OPTIONAL | V-DOB VIOLATION - ACTIVE | FTM.NUMEROUS SIGNIFICANT CRACKS OBSERVED @SOUTHEAST&EAST WALLS CRACK IN FINISHES OBSERVED@THE INTERIOR@ALL FLOORS.FLO... | — |
| Apr 29, 2024 | FEU10301XC | C-CONSTRUCTION OTHER OPTIONAL | V-DOB VIOLATION - ACTIVE | EMERGENCY WORK.DAMAGED BY EVACUATION AT ADJACENT LOT.EAST&SOUTH WALL GAVE SETTLED &MULTIPLE CRACK WE FOUND THROUGHOUT... | — |
| Feb 12, 2024 | 24-00346 | C-CONSTRUCTION OTHER OPTIONAL | V*-DOB VIOLATION - DISMISSED | PROPERTY IS UNDER FULL VACATE ORDER ISSUED 11/28/2023 DUE TO BUILDING BEING STRUCTURALLY COMPROMISED WITH SEAL COMPLE... | Apr 4, 2024 |
| Feb 12, 2024 | 18152 | IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL | V*-DOB VIOLATION - DISMISSED | REMEDY : SEAL ALL 1ST FLOOR ENTRANCES TO PROPERTY EXP #1 AND #3 | Feb 27, 2024 |
| Feb 7, 2024 | 00004 | AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE | V*-DOB VIOLATION - DISMISSED | FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION | Mar 24, 2025 |
| Dec 1, 2023 | 17983 | IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL | V*-DOB VIOLATION - DISMISSED | REMEDY: INSTALL TEMPORARY SHORING FROM CELLAR TO ROOF AS FOLLOWS: A) ADJACENT TO EXP 2 WALL DEPTH OF THE BUILDING. B)... | Jan 24, 2024 |
| Nov 30, 2023 | FEU10301XC | C-CONSTRUCTION OTHER OPTIONAL | V-DOB VIOLATION - ACTIVE | EMERGENCY WORK.DAMAGED BY EVACUATION AT ADJACENT LOT.EAST &SOUTH WALL HAVE SETTLED & MULTIPLE CRACK WE FOUND THROUGHO... | — |
| Nov 30, 2023 | FEU10302XC | C-CONSTRUCTION OTHER OPTIONAL | V-DOB VIOLATION - ACTIVE | FTM.NUMEROUS SIGNIFICANT CRACKS OBSERVED @SOUTH&EAST WALLS CRACK IN FINISHES OBSERVED@THE INTERIOR @ ALL FLOORS.FLOOR... | — |
| Nov 29, 2023 | 17979 | IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL | V*-DOB VIOLATION - DISMISSED | REMEDY: PROVIDE APPROXIMATELY 35 LINEAR FEET OF SIDEWALK SHE AT EXPOSU RE 1 TO SAFEQUARD THE PUBLIC AND PROPERTY | Dec 5, 2023 |
| Nov 29, 2023 | 17980 | IMEGNCY-IMMEDIATE EMERGENCY ANYTHINGOPTIONAL | V*-DOB VIOLATION - DISMISSED | REMEDY : PROVICE APPOXIMATELEY 27 LINEAR FEET OF CONSTRICTION FENCE AT EXPSURE 3 TO TH ELOT LINE WITH A RETURN OF APP... | Dec 5, 2023 |
| Nov 28, 2023 | CER01JK | C-CONSTRUCTION OTHER OPTIONAL | V-DOB VIOLATION - ACTIVE | STRUCTURE RENDERED NON-COMPLIANT DUE TO CRACKS OBSERVED ON FACADE IN MULTIPLE LOCATIONS IN ADDITION TO CRACKS ON THE ... | — |
| Mar 18, 1993 | 02017 | LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED | V-DOB VIOLATION - ACTIVE | — | — |
| May 9, 1990 | STA17M | ES-ELECTRIC SIGNS NONE | V-DOB VIOLATION - ACTIVE | — | — |