Skip to content

Maintenance code violations

127 Allen Street, Manhattan • Block 00415 • Lot 0032

401 records

HPD grades a violation A for non-hazardous through C for immediately hazardous.

Issued Class Status Violation Apartment Correct by
Feb 24, 2010 C VIOLATION CLOSED § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIG... Mar 2, 2010
Feb 24, 2010 C VIOLATION CLOSED § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM NO KEY PERSON ASSISTING INSPECTOR TO ACCESS THE L... Mar 2, 2010
Feb 17, 2010 B VIOLATION CLOSED § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4C, 4th STORY,... 4C Mar 24, 2010
Feb 16, 2010 C VIOLATION CLOSED § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM AT BLDG. CELLAR Feb 22, 2010
Feb 16, 2010 C VIOLATION CLOSED § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIG... Feb 22, 2010
Dec 28, 2009 C VIOLATION CLOSED § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR TO THE BOILER ROOM LOCKED Jan 3, 2010
Dec 28, 2009 C VIOLATION CLOSED § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF THE DOOR TO THE FIRE ESCAPE WINDOW LOCKED IN THE 3r... 4C Jan 3, 2010
Dec 28, 2009 B VIOLATION CLOSED § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANC... 4C Feb 1, 2010
Dec 28, 2009 B VIOLATION CLOSED § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4C, 4th STORY,... 4C Feb 1, 2010
Apr 22, 2009 C VIOLATION CLOSED § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE DOOR LOCK AT BUILDING ENTRANCE Apr 28, 2009
Jun 4, 2008 B VIOLATION CLOSED D26-10.01, 10.05 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS PUBLIC HALL BULKHEAD TO ROOF. Jul 9, 2008
Jun 4, 2008 B VIOLATION CLOSED § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE ... 5A Jul 9, 2008
Jun 4, 2008 B SECOND NO ACCESS TO RE-INSPECT VIOLATION § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING AT 5 STY SOUTHEAST APT 5A. LOCATED AT APT 5A 5A Jul 9, 2008
Jun 4, 2008 B SECOND NO ACCESS TO RE-INSPECT VIOLATION § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING AT 5 STY NORTHEAST APT 5C. LOCATED AT APT 5C 5C Jul 9, 2008
Jun 4, 2008 B VIOLATION CLOSED § 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN MICE & ROACHES AT 5 STY SOUTHWEST APT 5D THROUGHOUT. LOCAT... 5D Jul 9, 2008
Jun 4, 2008 B VIOLATION CLOSED § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING AT 5 STY SOUTHWEST APT 5D. LOCATED AT APT 5D 5D Jul 9, 2008
Jun 4, 2008 B VIOLATION CLOSED § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE ... 5D Jul 9, 2008
Jun 4, 2008 B VIOLATION CLOSED § 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN MICE & ROACHES AT 6 STY SOUTHEAST APT 6A THROUGHOUT. , SEC... 6A Jul 9, 2008
Jun 4, 2008 B VIOLATION CLOSED § 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN MICE & ROACHES AT 4 STY SOUTHWEST APT 4D THROUGHOUT. LOCAT... 4D Jul 9, 2008
Jun 4, 2008 B VIOLATION CLOSED § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING AT 4 STY SOUTHWEST APT 4D. LOCATED AT APT 4D 4D Jul 9, 2008
Jun 4, 2008 A VIOLATION CLOSED § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE TILE FLOOR OF BATHROOM OF 4 STY SOUT... 4D Sep 7, 2008
Jun 4, 2008 B VIOLATION CLOSED § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE CRACKED GLASS UPPER SASH OF WINDOW AT 4 STY SOUTHWEST APT... 4D Jul 9, 2008
Jun 4, 2008 B VIOLATION CLOSED § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BURNER OF STOVE AT 4 STY SOUTHWEST APT 4D KITCHEN. LOCATED... 4D Jul 9, 2008
Jun 4, 2008 B VIOLATION CLOSED § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE ... 4A Jul 9, 2008
Jun 4, 2008 B SECOND NO ACCESS TO RE-INSPECT VIOLATION § 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN MICE & ROACHES AT 3 STY SOUTHEAST APT 3A THROUGHOUT. LOCAT... 3A Jul 9, 2008
Jun 4, 2008 B VIOLATION CLOSED § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING 1 STY NORTHWEST APT 1C. LOCATED AT APT 1C 1C Jul 9, 2008
Jun 4, 2008 B VIOLATION CLOSED § 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN MICE & ROACHES AT 1 STY NORTHWEST APT 1C THROUGHOUT. LOCAT... 1C Jul 9, 2008
Jun 4, 2008 B VIOLATION CLOSED § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE ... 1C Jul 9, 2008
Jun 4, 2008 B VIOLATION CLOSED § 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN MICE & ROACHES AT 1 STY SOUTHWEST APT 1B THROUGHOUT. LOCAT... 1B Jul 9, 2008
Jun 4, 2008 A VIOLATION CLOSED § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING STEAM RADIATOR VALVE AT 1 STY SOUTHWEST APT 1B KITCHEN. LOCATED AT AP... 1B Sep 7, 2008
Jun 4, 2008 B VIOLATION CLOSED § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE ... 1B Jul 9, 2008
Jun 4, 2008 B VIOLATION CLOSED D26-20.08,20.09 ADM CODE PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEP... Jul 9, 2008
Jun 4, 2008 B VIOLATION CLOSED § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE ... 4D Jul 9, 2008
Feb 19, 2008 C VIOLATION CLOSED § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM THE DOOR LOCKED AT BOILER ROOM Feb 25, 2008
Nov 20, 2007 C SECOND NO ACCESS TO RE-INSPECT VIOLATION § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED... 3C Dec 16, 2007
Nov 20, 2007 C SECOND NO ACCESS TO RE-INSPECT VIOLATION § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED... 3C Dec 16, 2007
Mar 16, 2006 C SECOND NO ACCESS TO RE-INSPECT VIOLATION § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED... 1D Apr 11, 2006
Mar 16, 2006 C SECOND NO ACCESS TO RE-INSPECT VIOLATION § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED... 6A Apr 11, 2006
Mar 16, 2006 C SECOND NO ACCESS TO RE-INSPECT VIOLATION § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED... 6A Apr 11, 2006
Mar 16, 2006 C SECOND NO ACCESS TO RE-INSPECT VIOLATION § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED... 6A Apr 11, 2006
Dec 7, 2005 B VIOLATION CLOSED § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT CEILING ( 20 SQ FT. ) IN T... 2C Jan 16, 2006
Jan 4, 2005 C SECOND NO ACCESS TO RE-INSPECT VIOLATION § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED... 1D Jan 30, 2005
Dec 16, 2004 B VIOLATION CLOSED § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2A, 2nd STORY,... 2A Jan 25, 2005
May 26, 2004 B VIOLATION CLOSED § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING 5 STY NORTH... 5D Jul 5, 2004
May 26, 2004 B VIOLATION CLOSED § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILE 5 STY NORTHEAST A... 5D Jul 5, 2004
May 26, 2004 B VIOLATION CLOSED § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING 5 STY NORTH... 5D Jul 5, 2004
May 26, 2004 C SECOND NO ACCESS TO RE-INSPECT VIOLATION § 27-2029 ADM CODE DEVICE PRESENT ON CENTRAL HEATING SYSTEM WHICH IS CAPABLE OF CAUSING AN OTHERWISE OPERABLE SYSTEM ... Jun 6, 2004
May 26, 2004 B VIOLATION CLOSED § 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN MICE 5 STY NORTHEAST APT 5D THRU OUT. , SECTION '' '' 5D Jul 5, 2004
May 26, 2004 C VIOLATION CLOSED § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM BOILER ROOM DOOR LOCKED AT CELLAR Jun 6, 2004
Feb 10, 2003 C VIOLATION CLOSED § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 4B, 4th STORY, ... 4B Feb 21, 2003