ECB violations
225 Bowery, Manhattan • Block 00426 • Lot 0005
35 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jul 19, 2018 | 35332383P | RESOLVE | CLASS - 1 | HOUSEKEEPING. OBSERVED HOUSEKEEPING AT EXP #4 FOR STUCCO OPERATIONS WERE INADEQUATE, CONSISITING OF LARGE AMOUNTS OF ... | $2,500 | $0 | Sep 6, 2018 |
| Jul 19, 2018 | 35332382N | RESOLVE | CLASS - 2 | PEDESTRIAN PROTECTION INADEQUATE. OBSERVED PEDESTRIAN PROTECTION AT EXP #1 WAS INADEQUATE AND NOT AS PER APPROVED SIT... | $2,400 | $0 | Sep 6, 2018 |
| May 18, 2018 | 37010538L | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT ACCEPTABLE 8TH ROUND REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALLS AND APP... | $1,250 | $0 | Sep 20, 2018 |
| Mar 27, 2018 | 35318511J | RESOLVE | CLASS - 1 | HOIST NOT IN READINESS. @ TIME OF INSP OF AN ALT1 SITE 10 STORIES BLDG 1 FOUND THAT THE HOIST WAS SHUT DOWN BY THE EL... | $2,500 | $0 | May 17, 2018 |
| Sep 18, 2017 | 35265890M | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD PERSONS AND PROPERTY.IN RESPONSE TO AN INCIDENT OF A 14 STORY BUILDING CURRENTLY AT 13,IT WAS RE... | $25,000 | $0 | Nov 2, 2017 |
| Aug 26, 2017 | 35225377P | RESOLVE | CLASS - 2 | WORK AFTER HOURS W/O A VARIANCE WORK PERFORMED BY RESPONDENT ABOVE CD 4145 CN001917 DID NOT HAVE VARIANCE PERMIT FOR ... | $0 | $0 | Feb 8, 2018 |
| Mar 28, 2017 | 35237705N | RESOLVE | CLASS - 2 | PLANS WOKR DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS & OR APPROVED AMENDMENTS. NOTE: AT TIME OF INSPECTION ... | $0 | $0 | May 18, 2017 |
| Mar 21, 2017 | 35239605P | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD PUBLIC & PROPERTY DURING CONSTRUCTION OPERATIONS:IN RESPONSE TO INCIDENT #23593 UPON ARRIVAL AT ... | $5,000 | $0 | Jun 22, 2017 |
| Nov 28, 2016 | 35145393P | RESOLVE | CLASS - 1 | NOTED AT TIME OF INSPECTION SITE SAFETY PLAN INDICATES TO MAINTAIN 2 INTERIOR STAIRS AT ALL TIME MAINTAIN EGRESS. AT ... | $1,000 | $0 | Jan 19, 2017 |
| Nov 28, 2016 | 35145392N | RESOLVE | CLASS - 1 | WOKR W/O A PERMIT. NOTED AT TIME OF INSPECTION SCAFFOLD ERECTED ELEVATOR SHAFT 10 SECTIONS HIGH APPROX 60FEET. UPON R... | $1,600 | $0 | Jan 19, 2017 |
| Sep 13, 2016 | 35206841X | RESOLVE | CLASS - 1 | SEC: BC3309.10. NO ROOF PROTECTION. @ TIME OF INSP OBSERVED ALTERATION WORK ON A 10 STORIES BLDG. DURING THE INSP NOT... | $1,600 | -$30 | May 11, 2017 |
| Apr 11, 2016 | 35179070X | RESOLVE | CLASS - 1 | SMOKING AT CONSTRUCTION SITE. AT THE TIME OF MY INSPECTION,OF THE BLDGUNDER ALTERATION,I OBSERVED AT EXP#3 EVIDENCE O... | $2,400 | $0 | May 26, 2016 |
| Apr 11, 2016 | 35179069Z | RESOLVE | CLASS - 1 | WORK DOES NOT CONFORM TO APPROVED SITE SAFETY PLANS: AT THE TIME OF INSPECTION OF THE EXISTING BLDG UNDER ALTERATION.... | $1,000 | $0 | May 26, 2016 |
| Apr 11, 2016 | 35179068R | RESOLVE | CLASS - 1 | FAILURE TO INSTITUTE SAFETY MEASURES: NO TOE BOARDS. AT THE TIME OF MYINSPECTION OF THE EXISTING BLDG UNDER ALTERATIO... | $1,000 | $0 | May 26, 2016 |
| Apr 11, 2016 | 35179067P | RESOLVE | CLASS - 1 | FAILURE TO INSTITUTE SAFETY MEASURES: NO GUARDRAILS. AT THE TIME OF MYINSPECTION OF THE BLDG UNDER ALTERATION I OBSER... | $2,400 | $0 | May 26, 2016 |
| Jan 1, 2016 | 35170787M | RESOLVE | CLASS - 2 | SEC. 3307.6.5 FAILURE TO MAINTAIN SIDEWALK SHED AS REQUIRED BY CODE. NOTE: AT TIME OF INSPECTION,SIDEWALK SHED ERECTE... | $0 | $0 | Feb 18, 2016 |
| Dec 17, 2015 | 35162097P | RESOLVE | CLASS - 2 | BC 3310.6 DESIGNATED SITE SAFETY MANAGER NOTICED @TIME OF INSP ALT WORK IN PROGRESS NOTICED NO DESIGNATED(SSM)ON SITE... | $0 | $0 | Feb 4, 2016 |
| Aug 5, 2015 | 38238526L | RESOLVE | CLASS - 1 | 97R# - ILLEGAL USE OF DEVICE #1P30631 BRING USED AS A CONSTRUCTION ELEVATOR. RMDY: FILE APPLICATION TO OBTAIN PERMIT ... | $5,000 | $0 | Sep 24, 2015 |
| Aug 5, 2015 | 35145210N | RESOLVE | CLASS - 1 | STORAGE OF ALL VOLATICE FLAMMABLE COMBUSTIBLE GASES.AT TIME OF INSP.OBSERVED 3 GASOLINE CANS STORED INSIDE OF LOCKED ... | $0 | $0 | Feb 18, 2016 |
| Aug 5, 2015 | 35145207M | RESOLVE | CLASS - 1 | 3301.7 DESIGN REQUIRED,CONVEYOR SYSTEM.@ TIME OF INSP.OBSERVED ACTIVE JOBSITE.CONVEYOR SYSTEM BEING USED FOR DEBRIS/O... | $0 | $0 | Feb 18, 2016 |
| Aug 5, 2015 | 35145206K | RESOLVE | CLASS - 1 | FAILURE TO PERFORM SUCCESSFUL HYDROSTATIC PRESSURE TEST OF STAND PIPE SYSTEMS.@ TIME OF INSP.OBSERVED ACTIVE JOBSITE.... | $0 | $0 | Feb 18, 2016 |
| Aug 5, 2015 | 35145209X | RESOLVE | CLASS - 1 | 3301.2 HOLES/OPENINGS NOT COVERED AT TIME OF INSP.OBSERVED ACTIVE JOBSITE.10 STORIES,HOLES AND OPENINGS AT EVERY FLOO... | $1,600 | $0 | Feb 18, 2016 |
| Aug 5, 2015 | 35145204R | RESOLVE | CLASS - 1 | FAILURE TO HAVE SITE SAFETY CORRDINATOR PRESENT AS REQUIRED.AT TIME OF INSP.OBSERVED ACTIVE JOBSITE APPROX.20 WORKERS... | $2,400 | $0 | Jan 14, 2016 |
| Aug 5, 2015 | 35139365R | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE APPROVED/ACCEPTED PLANS AT JOBSITE AT TIME OF INSPECTION. AT THE TIME OF INSPECTION THE RESPONDENT... | $250 | $0 | Feb 18, 2016 |
| Aug 5, 2015 | 35139366Z | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE APPROVED/ACCEPTED PLANS AT THE JOBSITE.THE RESPOND ENT FAILED TO PROVIDE PLANS FOR THE SUPPORT OF ... | $250 | $0 | Feb 18, 2016 |
| Aug 5, 2015 | 35145205Z | RESOLVE | CLASS - 1 | 3303.12 HOIST-FAILURE TO HAVE ELEVATOR IN READINESS.AT TIME OF INSP.OBSERVED ACTIVE JOBSITE USING EXISTING INTERIOR P... | $1,600 | $0 | Feb 18, 2016 |
| Aug 5, 2015 | 35145208Y | RESOLVE | CLASS - 1 | FAILURE TO INSTITUTE/MAINTAIN,GUARDRAIL SYSTEM.@ TIME OF INSP.OBSERVED ACTIVE JOBSITE.10 STORY BLDG USING CABLE SYSTE... | $2,400 | $0 | Feb 18, 2016 |
| Mar 23, 2015 | 35118239N | RESOLVE | CLASS - 2 | FAILURE TO SAFEGUARD ALL PERSONS AND PROEPRTY AFFECTED BY CONSTRUCTIONOPERATION.THERE WAS NO FIRE EXTINGUISHER AND TH... | $1,200 | $0 | Jun 25, 2015 |
| Mar 23, 2015 | 35118238L | RESOLVE | CLASS - 1 | FAILURE TO NOTIFY THE DOB WITHIN 24 TO 48 HOURS OF THE START OF EXCAVATION.OBSERVE EXCAVATION AT THE CELLAR LEVEL AND... | $1,200 | $0 | Jun 25, 2015 |
| Mar 23, 2015 | 35118237J | RESOLVE | CLASS - 2 | BC1814.1 FAILURE TO PREPARE AND PROVIDE SITE SPECIFIC PLANS,DETAILS AND SEQUENCE OF CONSTRUCTION FOR UNDERPINNING AND... | $0 | $0 | May 7, 2015 |
| Jul 17, 2008 | 34685176J | RESOLVE | CLASS - 2 | SIDEWALK SHED DOES NOT MEET CODE SPECIFICATIONS. NOTED: NO LIGHTS UNDER SIDEWALK SHED. REMEDY: CONFORM SHED TO CODE S... | $10,000 | $0 | Sep 11, 2008 |
| Mar 28, 2008 | 34684080K | RESOLVE | Non-Hazardous | FAILURE TO FILE AN AMENDED 6TH ROUND REPORT ACCEPTABLE TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRI... | $2,500 | $0 | Oct 30, 2008 |
| Jun 18, 1996 | 38055592H | RESOLVE | Non-Hazardous | 39, 39-REGROOVE TRACTION SHEEAVE 74- REPAIR FIREMENS CONTROL. | $200 | $0 | Aug 29, 1996 |
| Jan 26, 1993 | 38031774M | RESOLVE | Non-Hazardous | 73#, #73 PERFORM 5 YR TEST, PROPERLY TAG DEVICE & FILE ELEV. 3 FORM | $0 | $0 | Apr 1, 1993 |
| Jan 26, 1993 | 38031773K | RESOLVE | Non-Hazardous | 73#, #73 PERFORM 5 YR TEST, PROPERLY TAG DEVICE & FILE ELEV 3 FORM | $0 | $0 | Apr 1, 1993 |