141 Avenue A, Manhattan • Block 00436 • Lot 0029
31 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Aug 10, 2023 | 39092262Y | RESOLVE | CLASS - 2 | I OBSERVED IN HALLWAY ON 4TH FLOOR FOR APT #5 GAS PIPING INSTALLED IN HALLWAY AND UNION INSTALLED ON MAIN GAS LINE FO... | $0 | $0 | Mar 7, 2024 |
| Oct 2, 2020 | 39029736P | RESOLVE | CLASS - 1 | CEASE USE GAS HOT WATER HEATER PGXH50 248// FLUE NOT CONNECTED TO THE CHIMNEYÝGAS PIPE CONNECTED+WATER PIPES CONNECTE... | $1,250 | $0 | May 12, 2022 |
| Oct 2, 2020 | 39029734L | RESOLVE | CLASS - 2 | CORRECT VIOLATION AND SUBMIT THE CERTIFICATE OF CORRECTION | $312 | $0 | Apr 22, 2021 |
| Oct 2, 2020 | 39029735N | RESOLVE | CLASS - 2 | THE HOT WATER STORAGE TANK SAFETY VALVE IS INCORRECT Ý1" VALVE ON 3/4 TAP¨; CORRECT VIOLATION AND SUBMIT THE CERTIFIC... | $312 | $0 | May 12, 2022 |
| Mar 20, 2018 | 32093003J | RESOLVE | CLASS - 2 | 15,24,34,50A. (50A)IMPROPER FLUE SUPPORT. CORRECT ALL LISTED VIOLATION & SUBMIT C OF C. | $625 | $0 | Nov 1, 2018 |
| Jul 17, 2009 | 34791732K | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES. NOTED: ON LEFT SIDE (EXP 2) NEAR FRONT STUCCO IS CRACKING LARGE AND ... | $2,500 | $0 | Feb 18, 2010 |
| Mar 4, 2009 | 34756345R | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED CONST OPERATIONS NOTED SUPPORTED SCAFFOLD ERECTED IMPROPERLY O... | $12,000 | $0 | Jul 23, 2009 |
| Mar 4, 2009 | 34756347K | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN LIGHTING UNDER SIDEWALK SHED WITH VANDLE PROOF FIXTURES NOTED LIGHTING UNDER SHED WITH PERMIT 110... | $10,000 | $0 | Jul 23, 2009 |
| Mar 4, 2009 | 34756346Z | RESOLVE | CLASS - 1 | FAILURE TO REMOVE SIDEWALK SHED PROMPTLY AFTER WORK HAS BEEN COMPLETED NOTED FACADE WORK IS COMPLETE AS PER LANDLORD ... | $0 | $0 | Jul 29, 2009 |
| Nov 28, 2008 | 34740600Z | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG WALL(S) OR APPURTENANCES. DEFECTS NOTED: CORNER OF FRONT WALL & EAST WALL (EXP #12 #2) CRACK... | $5,000 | $0 | Jun 11, 2009 |
| Aug 1, 2008 | 34697760R | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN EXTERIOR OF BLDG. ON INSPECTION APPROX 5 WINDOWS HAVE BEEN INSTALLED ON REAR SOUTH SIDE OF BLDG F... | $5,000 | $0 | Nov 13, 2008 |
| Sep 2, 2006 | 34535098J | RESOLVE | Non-Hazardous | HAVING PROHIBITED ADVERTISING SIGNAGE IN A C1-5 DISTRICT. REMEDY:REMOVE ILLEGAL SIGNAGE. | $800 | $0 | Oct 4, 2007 |
| Sep 2, 2006 | 34526974X | RESOLVE | Non-Hazardous | HAVING SIGNAGE IN VIOLATION OF SIGN FOR RESIDENCE DISTRICTS (C1-5) LOCATED IN THE RESIDENTIAL PORTION OF A MIXED BLDG... | $800 | $0 | Oct 4, 2007 |
| Sep 2, 2006 | 34528324N | RESOLVE | Non-Hazardous | HAVING SIGNAGE EXTENDING HIGHER THEN 25FT ABOVE CURB LEVEL IN A C1-5 DISTRICT. REMEDY: REMOVE ILLEGAL SIGNAGE | $800 | $0 | Oct 4, 2007 |
| Sep 2, 2006 | 34535099L | RESOLVE | Non-Hazardous | HAVING SIGNAGE W/ A SURFACE AREA GREATER THAN 150 SQ FT IN A C1-5 DISTRICT. REMEDY:REMOVE ILLEGAL SIGNAGE. | $800 | $0 | Oct 4, 2007 |
| Sep 2, 2006 | 34535097H | RESOLVE | Non-Hazardous | HAVING SIGNAGE WHICH IS LOCATED ON A PORTION OF FRONTAGE THAT IS W/IN 20 FT OF FRONTAGE ON THE SAME SIDE OF STREET IN... | $800 | $0 | Oct 4, 2007 |
| Sep 2, 2006 | 34535096X | RESOLVE | Non-Hazardous | WORK W/O A PERMIT. WORK NOTED: APPROX 35' X 15' SIGN ATTACHED TO BLDG.REMEDY:OBTAIN A PERMIT OR RESTORE TO PRIOR LEGA... | $2,500 | $0 | Nov 9, 2006 |
| Jun 8, 2006 | 34527203M | RESOLVE | Hazardous | EXIT PASSAGE OR CORRIDOR:REQUIRED WIDTH DECREASED BY OBSTRUCTION NOTED:AT 1ST FL OF PREMISES FRONT ENTRANCE CORRIDOR ... | $180 | $0 | Jul 27, 2006 |
| Apr 22, 2003 | 34392731K | RESOLVE | Hazardous | FAILURE TO MAINTAIN EXTERIOR BLDG NOTED:THE METAL CORNICE AND ORNAMENTAL WINDOW TREATMENTS ON THE NORTH AND EAST WALL... | $800 | $0 | Oct 2, 2003 |
| Apr 21, 2003 | 34401386K | RESOLVE | Hazardous | PLUMBING WORK PERFORMED WAS REQUIRED TO BE PERFORMED BY A LICENSED MASTER PLUMBER. ON 2ND FLOOR-THIS APARTMENT IS GET... | $400 | $0 | Aug 7, 2003 |
| Apr 21, 2003 | 34401387M | RESOLVE | Hazardous | FAILURE TO HAVE NEW OR ALTERED PLUMBING SYSTEM TESTED. ON 2ND FLOOR - THIS APARTMENT IS GETTING SPLIT INTO TWO APARTM... | $400 | $0 | Aug 7, 2003 |
| Apr 21, 2003 | 34401388Y | RESOLVE | Hazardous | USE OR INSTALLATION OF PLUMBING MATERIALS WHICH DO NOT COMPLY WITH RS-16- QUICK VENTS ARE NOT ALLOWED! 3-QUICK VENTS ... | $400 | $0 | Aug 7, 2003 |
| Apr 21, 2003 | 34401385Z | RESOLVE | Hazardous | PLUMBING WORK WITHOUT A PERMIT. ON 2ND FLOOR - THIS APARTMENT IS GETTING SPLIT INTO TWO APARTMENTS AND THE DEMOLITION... | $800 | $0 | Aug 7, 2003 |
| Apr 1, 2002 | 34323858Z | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE APPROVED SET OF PLANS AT TIME OF INSPECTION PERMIT#103119876 EXP 3/30/03 POSTED NOTED: 2 APARTMENT... | $0 | $0 | May 16, 2002 |
| Jul 10, 2001 | 34285821K | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT (25% OF WORK COMPLETED) NOTED: ENLARGING OPENING OF ONE REAR WINDOW MAKING IT APPROX 6" WIDER +... | $500 | $0 | Aug 25, 2005 |
| Dec 23, 1999 | 34234558M | RESOLVE | Hazardous | FAILURE TO MAINTAIN PLUMBING AND / R APPURTENANCES -HAZARDOUS. REMEDY: MAINTAIN PLUMBING AND /OR APPURTANANCES | $2,500 | $0 | Jul 20, 2000 |
| Jul 14, 1999 | 34217590H | RESOLVE | Non-Hazardous | WORK WITHOU TA PERMIT NOTED AT REAR OF BLDG EXHAUST CHIMNEY DUCTION CONSTUCTED OF METAL ISNTALLED FROM 1ST FL LECEL T... | $0 | $0 | Sep 2, 1999 |
| Dec 27, 1995 | 34132749H | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT. NOTED. INSTALLED EXAUST CHIMNEY (METAL) FROM 1ST THROUGH 5TH FLOOR AT REAR OF BLDG. REMEDY: OB... | $350 | $0 | Mar 28, 1996 |
| Apr 20, 1994 | 34104324Y | RESOLVE | Non-Hazardous | OCCUPYING ALTERED BUILING WITHOUT A NEW CERTIFICATE OF OCCUPANCY . ALT. #1393/81 1ST FLOOR EATIN AND DRINKING ESTABLI... | $350 | $0 | Jun 23, 1994 |
| Sep 28, 1992 | 34078378N | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT. WORK NOTED. INSTALLATION OF AN EXHAUST CHIMNEY 1ST TO 5TH STORY AT REAR OF BUILDING. REMEDY. O... | $350 | $0 | May 13, 1993 |
| Jun 16, 1988 | 34007976P | RESOLVE | Non-Hazardous | OCCUPYING ALTERED BUILDING WITHOUT A NEW C OF O. REMEDY: OBTAIN A NEW C OF O FROM THIS DEPARTMENT. | $250 | $0 | Nov 22, 1988 |