313-327 East 13 Street, Manhattan
Manhattan • Block 00455 • Lot 0052 • Zip: 10003
Condition
What the city currently has open against this building, counted from its own records.
Address
Land use and zoning
Building
Latest assessment
Neighborhood
The area this lot falls inside, and the commute Hoodkit measures from it.
Getting around
Estimated 5 days ago- Union Square 13 min 8 walking, 5 riding
- Grand Central 23 min 8 walking, 15 riding
- Times Square 24 min 8 walking, 16 riding
- Penn Station 26 min 8 walking, 18 riding
- Fulton Street 26 min 8 walking, 18 riding
- Downtown Brooklyn 33 min 8 walking, 25 riding
Around this address
Transit and places within 0.5 miles of the lot.
Getting out
Subway
Railroad
Ferry
Bus
Citi Bike
Places nearby
Claud
No description yet
Pizza Studio Tamaki
No description yet
Superiority Burger
Superiority Burger is a small, trendy vegetarian restaurant in the East Village offering creative plant-based burgers...
Veselka
Lively Ukrainian restaurant known for its borscht and pierogi, featuring a rustic atmosphere and colorful wall murals.
Penny
Penny is a hidden gem in the heart of East Village, offering a cozy and inviting atmosphere. They specialize in eclec...
Electric Burrito
Electric Burrito is a vibrant Mexican eatery in the heart of NYC's East Village. Our menu boasts mouthwatering burrit...
Baohaus
No description yet
B & H Dairy
No description yet
Activity
Sales, filings, permits and violations from every dataset, in one order.
2022
-
DOB violation Feb 22, 2022
FISPNRF-NO REPORT AND / OR LATE FILING (FACADE) FACADE REQUIRED
FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022
2021
-
CLASS - 2
FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8A REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA...
2019
-
New Building
PLANS FOR SUPPORT OF EXCAVATION AND TEMPORARY UNDERPINNING ARE FILED HEREWITH FOR THE NEW HOSPITAL BUILDING.
-
DOB violation Feb 16, 2019
BENCH-FAILURE TO BENCHMARK NONE
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
2018
-
Alteration Type III
INSTALLATION OF A TORNBORG 6000 SINGLE CAR PERSONNEL/MATERIAL HOIST AS PER PLANS DURING GENERAL CONSTRUCTION WORK. NO...
-
Alteration Type III
PROPOSED INSTALLATION OF HEAVY DUTY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
-
Alteration Type III
PROPOSED INSTALLATION OF FENCE AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
-
Alteration Type III
PROPOSED INSTALLATION OF PIPE SCAFFOLD AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
-
HPD violation Oct 5, 2018
Class I
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27...
-
Alteration Type II
CONVERSION OF WET STANDPIPE TO DRY AIR-PRESSURIZED SYSTEM. THERE IS NO CHANGE IN EGRESS, USE OR OCCUPANCY.
-
DOB violation May 31, 2018
FISPNRF-NO REPORT AND / OR LATE FILING (FACADE) FACADE REQUIRED
FAILED TO FILE FISP CYCLE 8A TECHNICAL REPORT BY 02/21/2017
-
CLASS - 2
FAILURE TO SUBMIT ACCEPTABLE 8TH ROUND REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALLS & APPUR...
-
DOB violation Feb 2, 2018
BENCH-FAILURE TO BENCHMARK NONE
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
-
CLASS - 1
FAILURE TO PROVIDE REQUIRED NOTIFICATION PRIOR TO THE COMMENCEMENT OF DEMOLITION.AT TIME OF INSPECTION NOTED ON BIS T...
2017
-
HPD violation Nov 6, 2017
Class I
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27...
-
DOB violation Nov 2, 2017
BENCH-FAILURE TO BENCHMARK NONE
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
-
DOB violation Sep 15, 2017
EVCAT1-ELEVATOR ANNUAL INSPECTION / TEST ELEVATORREQUIRED
VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2016 INSPECTION/TEST
-
CLASS - 1
WORK AFTER HOURS W/O A VARIANCE PERMIT CONTRARY TO 28-105.12.5: ASBESTOS ABATEMENT OCCURRING AT TIME OF INSPECTION ON...
2016
-
HPD violation Oct 24, 2016
Class I
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27...
2012
-
CLASS - 2
SIDEWALK SHED DOES NOT MEET DOB CODE SPECIFICATIONS. NOTED:MISSING HORIZONTAL BRACES DETACHED CROSS BRACES MISSING BO...
-
CLASS - 2
45B07. 45B- CAR SPEED READS 150 FPM, AS PER DOB RECORDS AND MACHINE, GOVERNOR DATA - READS 250 FPM. BRING UP TO SPEED...
The most recent 6 events from each dataset, so no one source takes the axis. Each tab holds the full record.
Property Contacts
Contact information aggregated from multiple government sources
Building Permits
Owner information from Department of Buildings filings
Recent Building Permits
Owner information from recent DOB NOW filings
Deed Records
Parties from ACRIS deed and mortgage records
Property Records
Owner information from assessment and PLUTO records