| Jun 10, 2026 | 39191940H | ACTIVE | CLASS - 2 | FTM GAS HOT WATER HEATER MODEL#G76-200-1 RATED AT 199900 BTUS INSTALLED WITHOUIT A PERMIT, MAINTAIN BOILER; PULL PROP... | $1,250 | $1,250 | Aug 20, 2026 |
| Jun 10, 2026 | 39192028Y | ACTIVE | CLASS - 1 | ATOI OBSERVED UNPERMITTED LAUNDRY ROOM ON 2ND FLR, OPEN GAS LINES, THROUGHOUT THE BUILDING NO TRAP WRAPS ON LAVATORY ... | $2,500 | $2,500 | Aug 20, 2026 |
| Feb 11, 2025 | 37033327N | ACTIVE | CLASS - 2 | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS #39108298J ISSUED ON 03/11/2024, AND FAILURE TO FILE... | $625 | $0 | May 8, 2025 |
| Feb 11, 2025 | 37033326L | ACTIVE | CLASS - 2 | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS #39108297H ISSUED ON 03/11/2024, AND FAILURE TO FILE... | $625 | $0 | May 8, 2025 |
| Jul 23, 2024 | 39119724R | RESOLVE | CLASS - 1 | UNLAWFUL ACTS: FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION# 39108750R ISSUED ON 3/1... | $2,500 | $0 | Sep 26, 2024 |
| Mar 27, 2024 | 39110060M | ACTIVE | CLASS - 2 | OBSERVED IN THE CONFERENCE ROOM LOCATED ON THE 2ND FLOOR TWO SPRINKLER CAPS PAINTED OVER. AS PER 102.3 OF THE PLUMBIN... | $312 | $0 | Jun 13, 2024 |
| Mar 14, 2024 | 39108753M | RESOLVE | CLASS - 2 | EMERGENCY EXIT DOOR DOES NOT FUNCTION, (ONLY ONE HALF OPENS), GROUND FLOOR, EXPOSURE #1, LEFT SIDE., PROVIDE PROPER C... | $312 | $0 | May 23, 2024 |
| Mar 14, 2024 | 39108750R | ACTIVE | CLASS - 1 | LARGE CRACKS AND DETACHED STUCCO WAS DISCOVERED ON FACADE LOCATED AT ROOF/PARAPET LEVEL, EXPOSURE #4., REPAIR AND/REP... | $1,250 | $0 | May 23, 2024 |
| Mar 14, 2024 | 39108752K | ACTIVE | CLASS - 2 | UNPERMITTED, EXCESSIVE, AND CONBUSTIBLE STORAGE AROUND AND NEAR MECHANICAL DEVICES, (HOT WATER HEATER AND GAS METER) ... | $312 | $0 | May 23, 2024 |
| Mar 11, 2024 | 39108298J | RESOLVE | CLASS - 2 | IN-CAR COMMUNICATION INOPERATIVE. IN-CAR FAN INOPERATIVE. PROVIDE AN UPDATED MAINTENACE LOG. | $625 | $0 | May 16, 2024 |
| Mar 11, 2024 | 39108297H | RESOLVE | CLASS - 2 | IN-CAR COMMUNICATION INOPERATIVE. IN-CAR FAN INOPERATIVE. MISSING MIRROR IN CAR. PROVIDE A UPDATED MAINTENANCE LOG. | $625 | $0 | May 16, 2024 |
| Apr 20, 2023 | 39084275N | RESOLVE | CLASS - 2 | AT FRONT OF BUILDING, AT LEFT SIDE, AT 5TH FLOOR, MASONRY COLUMN HAS VERTICAL CRACK APPROXIMATELY 6' IN LENGTH., MAIN... | $0 | $0 | Jun 29, 2023 |
| Nov 30, 2022 | 39074753J | RESOLVE | CLASS - 1 | ELEVATOR CURRENTLY SITTING IN THE LOBBY WITH DOORS CLOSED AND POWER DISCONNECTED; ELEVATOR CURRENTLY OUT OF SERVICE; ... | $1,250 | $0 | Feb 9, 2023 |
| Jun 21, 2022 | 39064493N | RESOLVE | CLASS - 1 | CLASS 1 RESTORE TO SERVICE FOR PROPER INSPECTION BY DOB. | $1,250 | $0 | Sep 29, 2022 |
| Jun 14, 2021 | 39042742H | RESOLVE | CLASS - 1 | FOUND DOOR LOCK MONITORING IS NOT WORKING. REPAIR AND ADJUST. | $1,250 | $0 | Jul 29, 2021 |
| Jun 14, 2021 | 39042743J | RESOLVE | CLASS - 1 | FOUND DOOR RESTRICTOR IS NOT WORKING. CEASE USED. REPAIR AND ADJUST THE DOOR RESTRICTOR. RE-INSPECTION IS REQUIRED. | $1,250 | $0 | Jul 29, 2021 |
| Mar 2, 2020 | 39018704R | RESOLVE | CLASS - 1 | NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE2014 NYCBC.THIS IS A... | $1,250 | $0 | May 28, 2020 |
| Mar 2, 2020 | 39018705Z | RESOLVE | CLASS - 1 | NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS... | $1,250 | $0 | May 28, 2020 |
| Sep 4, 2019 | 39008928R | RESOLVE | CLASS - 1 | I OBSERVED IN THE WATER METER ROOM THE DETERIORATION OF THE WATER GROUND CLAMPS AND THE GROUND ELECTRODE CONDUCTOR., ... | $1,600 | $0 | Oct 30, 2019 |
| Sep 4, 2019 | 39008927P | RESOLVE | CLASS - 2 | I OBSERVED IN THE 6TH FLOOR MEN'S NEAR STAIRWELL B A DEFECTIVE/MISWIRED GFCI RECEPTACLE., INSTALL GFC1 PROTECTION | $1,200 | $0 | Oct 30, 2019 |
| Jan 17, 2019 | 38267346R | RESOLVE | CLASS - 2 | 16B7 MISSING RELEASE ROLLER ON EVERY FLOOR PROVIDE. | $0 | $0 | Mar 14, 2019 |
| Dec 28, 2017 | 38260330K | RESOLVE | CLASS - 2 | 2X10. OUTSIDE COMM INOPERATIVE REPAIR. | $0 | $0 | Feb 15, 2018 |
| Oct 12, 2017 | 35294092K | RESOLVE | CLASS - 1 | RE-ISSUE#35290297X FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVED IN CELLAR JUNCTION BOX(PULL BOX)FOR SE... | $2,500 | $0 | Dec 21, 2017 |
| Sep 1, 2017 | 35290297X | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVED IN CELLAR NEXT TO GAS METER ROOM: ELECTRICAL JUNCTION BOX... | $1,000 | $0 | Oct 19, 2017 |
| Mar 22, 2017 | 35235570X | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVED ON 3-22-17 AT ABOVE ADDRESS NO GAUGE ON SPRINKLER BRANCH ... | $0 | $0 | Jun 22, 2017 |
| Mar 22, 2017 | 35235569Z | RESOLVE | CLASS - 1 | SEC. 4038 UNPAINTED GAS PIPING-NOT PROTECTED FROM CORROSION OBSERVED ON 3-22-17 ON ROOF LEVEL GAS PIPING TO HEATING N... | $1,600 | $0 | May 11, 2017 |
| Oct 19, 2016 | 35214522Z | RESOLVE | CLASS - 2 | FAIL TO MAINTAIN BLDG IN CODE COMPLIANT MANNER RE: INSTALLATION/MAINTENANCE OF PLUMBING MATERIALS/EQUIPMENT PER PC 10... | $500 | $0 | Dec 8, 2016 |
| Oct 19, 2016 | 35214521R | RESOLVE | CLASS - 1 | DRIPS-FUTURE CONNECTS EXIST DOWN STREAM OF APPLIANCE. MISC VIOLATION. OBSERVED ON 10/19/16 FUTURE GAS CONNECTION IN B... | $0 | $0 | Feb 2, 2017 |
| Mar 7, 2016 | 35177114J | RESOLVE | CLASS - 2 | WORK W/O A PERMIT. WORK NOTED: AT 2ND FL LEVEL INSTALLED WATER & WASTELINES FOR WASHING MAACHINES & GAS LINE FOR DRYE... | $0 | $0 | Jul 28, 2016 |
| Mar 7, 2016 | 35177115L | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER: LACK OF EMERGENCY LIGHTING FOR EXITS. EXIT DISCHARGES & PUBLIC COR... | $250 | $0 | Jul 28, 2016 |
| Jun 16, 2015 | 38236341X | RESOLVE | CLASS - 2 | 48Q11,48Y02,68B07 48Q11-PUMP UNIT UNGUARDED REPLACE COVER; 48Y02-PUMPUNIT OIL LEAK IN PAN CLEAN; 68B07-MAINTENANCE LO... | $250 | $0 | Aug 6, 2015 |
| Jun 16, 2015 | 38236342H | RESOLVE | CLASS - 2 | 21H11,68B07,100B09. 21H11-INTERLOCK RELEASE ROLLERS WORN ON 1ST FLR & 2ND FLR REPLACE; 68B07-MAINTENANCE LOG INSUFFIC... | $250 | $0 | Aug 6, 2015 |
| Jun 10, 2002 | 34320588Y | RESOLVE | Non-Hazardous | FAILURE TO OBTAIN A PERMIT FOR TEMPORARY CONSTRUCTION .SIDEWALK SHED PERMIT #102943923 EXPIRED ON 4/1/02 REMEDY:REMOV... | $0 | $0 | Jan 15, 2004 |
| Feb 17, 1999 | 38084212J | RESOLVE | Non-Hazardous | 35O2,57Y2,74M5,74B14. 35-CLEAN MR CAR TOP & PIT EQUIPMENT. 57-CLEAN OIL FROM MR FL. 74M-CURRENT 3 YR TEST TAG IS MISS... | $0 | $0 | Apr 9, 1999 |
| Aug 5, 1998 | 34146757P | RESOLVE | Hazardous | SUPERVISION OR USE OF RIGGING EQUIPMENT WITOUT MASTER RIGGERS LICENSE OPERATION OF ACRANE WITHOUT A CERTICATE OF APPR... | $0 | $0 | Nov 5, 1998 |
| Dec 7, 1989 | 34032078H | RESOLVE | Hazardous | FAILURE TO MAINTAIN: EXCESSIVE EROSION OF MORTAR OF CHIMNEY AT SOUTHEAST AREA OF ROOF. REMEDY: MAKE NECESSARY REPAIRS... | $0 | $0 | Mar 1, 1990 |
| Dec 7, 1989 | 34032420Y | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT. ERECTION OF PARTITIONS CREATING AN OFFICE AREA IN FRONT OF RESTAURANT. | $250 | $0 | Mar 1, 1990 |
| Dec 7, 1989 | 34032419R | RESOLVE | Hazardous | FAILURE TO MAINTAIN. FIRE RATING MISSING ON CEILING OF HALLWAY LEADING TO BASEMENT BACK EXIT OF RESTAURANT. REMEDY: M... | $500 | $0 | Mar 1, 1990 |
| Dec 7, 1989 | 34032423J | RESOLVE | Hazardous | FAILURE TO MAINTAIN. LOOSE AND DEFECTIVE THREADS ON STAIRWAY BETWEEN 4TH AND 2ND FLOORS. REMEDY: MAKE NECESSARY REPAI... | $500 | $0 | Mar 1, 1990 |
| Dec 7, 1989 | 34032418P | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE VENTILATION FOR A BATHROOM OF THE 1ST FLOOR-REAR OF RESTAURANT. REMEDY: MAKE NECESSARY REPAIRS TO ... | $100 | $0 | Mar 1, 1990 |
| Dec 7, 1989 | 34032422H | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT. BRICKING UP A WINDOW AT THE BACK OF THE BUILDING. REMEDY: OBTAIN NECESSARY PERMITS OR RESTORE ... | $0 | $0 | Mar 1, 1990 |