ECB violations

13-21 3 Avenue, Manhattan • Block 00463 • Lot 0007

19 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Feb 18, 2025 39138758Z RESOLVE CLASS - 2 WORK WITHOUT A PERMIT. AT TIME OF INSPECTION, NOTED EXTERIOR WOODEN DINING STRUCTURE, APPROXIMATELY 26'L X 6'D, ATTAC... $1,250 $1,250 Apr 7, 2026
Feb 18, 2025 39138759K RESOLVE CLASS - 3 WORK WITHOUT ELECTRICAL PERMIT. AT TIME OF INSPECTION, NOTED EXTERIOR LIGHTING INSTALLED ON WOODEN STRUCTURE WITHOUT ... $200 $200 Apr 7, 2026
Apr 16, 2020 39021221J ACTIVE CLASS - 2 FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. AT TIME OF INSPECTION, OBSERVED HVAC UNIT INSTALLED ON TOP O... $3,125 $3,125 Aug 10, 2020
Oct 28, 2015 35161753J RESOLVE CLASS - 1 3309.1 PROTECTION OF ADJOINING PROPERTY.AT TIME OF INSPECTION,BUILDINGREACH EXCAVATION OF 7 FLS. NO ROOF PROTECTION O... $1,600 $0 Dec 17, 2015
Jul 13, 2011 34923631N RESOLVE CLASS - 1 XCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERT OF OCCUPANCY OR DOB RECORD.NOTED:BLDG HAVING ON 3 FLR 19 MOTEL (CLASS ... $2,400 $0 Dec 15, 2011
Jul 13, 2011 34923632P RESOLVE CLASS - 2 BC1003.2)FAILURE TO PROVIDE MIN CEILING HEIGHT FOR MEANS OF EGRESS.NOTED:2 FLR MEANS OF EGRESS-PUBLIC CORRIDOR @ SEC ... $0 $0 Sep 1, 2011
Jul 13, 2011 34923633R RESOLVE CLASS - 2 BC1208.2)FAILURE TO PROVIDE MIN CEILING HEIGHT FOR HABITABLE ROOMS.NOTED:SECTION 'C' & 'D' OF BLDG HAVING HOTEL ROOMS... $0 $0 Sep 1, 2011
Jun 1, 2011 34896279M RESOLVE CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER. FOUND DEDICATED FIRE SPRINKLER SYSTEM W/APPROX 133 SPRINKLER HEADS... $0 $0 Jul 21, 2011
May 1, 2011 34907298Z RESOLVE CLASS - 2 SEC. 715.3 FAILURE TO PROVIDE FIRE RATED DOOR AS PER BC 715.3 & TABLE 715.3. NOTED: "ST MARKS HOTEL" HAVING ON 2ND FL... $0 $0 Jun 23, 2011
May 1, 2011 34907296P RESOLVE CLASS - 2 WORK W/O A PERMIT. WORK NOTED: BUILDING HAVING ERECTED: OVER 1ST FL REAR EXTENSION ROOF TOP STRUCTURE 1 EXTERIOR WALL... $800 $0 Jul 21, 2011
May 1, 2011 34907291X RESOLVE CLASS - 2 SEC. 1003.2 FAILURE TO PROVIDE MINIMUM CEILING HEIGHT FOR MEANS OF EGRESS. NOTED: BUILDING HAVING ON 3RD FL SECTION "... $800 $0 Jul 21, 2011
May 1, 2011 34907297R RESOLVE CLASS - 2 SEC. 32-412 FAILURE TO COMPLY W/USES LOCATED W/I COMPLETELY ENCLOSED BUILDING IN A C6-1 ZONING DISTRICT. NOTED: STORE... $0 $0 Jun 23, 2011
May 1, 2011 34907294L RESOLVE CLASS - 1 FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. OBSTRUCTION NOTED: BUILDING HAVING FOR "ST MARKS HOTEL" SECONDARY ME... $1,200 $0 Jul 21, 2011
May 1, 2011 34907295N RESOLVE CLASS - 1 SEC. 1023.1 FAILURE TO PROVIDE EXIT DISCHARGE DIRECTLY TO THE EXTERIOROF THE BUILDING. NOTED: "ST MARKS HOTEL" LOCATE... $1,600 $0 Jul 25, 2011
May 1, 2011 34907292H RESOLVE CLASS - 1 SEC. 1001.4 FAILURE TO PROVIDE REQUIRED MEANS OF EGRESS FROM ROOM OR SPACE. NOTED: BUILDING OCCUPIED FROM 2ND FL TO 4... $0 $0 Jul 11, 2011
May 1, 2011 34907293J RESOLVE CLASS - 1 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OF O OR BUILDING DEPT RECORDS. NOTED: BUILDING HAVING CONVERTED ENTIRE 2N... $0 $0 Jul 11, 2011
May 1, 2011 34907290Y RESOLVE CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: ILLUMINATION FOR EXITS,EXIT DISCHARGES & PUBLIC CORRIDORS PER ... $0 $0 Jun 23, 2011
Aug 2, 1993 34092385M RESOLVE Hazardous FAILURE TO PROVIDE APPROVED PLANS @ TIME OF INSPECTION REMEDY PROVIDE APPROVED PLANS $125 $0 Sep 30, 1993
Jan 9, 1989 34020965X RESOLVE Unknown FAILURE TO FILE ANNUAL BOILER REPORT WITH THIS DEPT FOR BOILER 89921-01 REMEDY FILE REPORT OR HAVE AN INSPECTION PERF... $100 $0 Mar 16, 1989