ECB violations
44-52 Crosby Street, Manhattan • Block 00483 • Lot 0007
46 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Sep 21, 2015 | 37000195J | RESOLVE | CLASS - 2 | 28-317.3 FAILURE TO REGISTER COOLING TOWER. RMDY: COMPLY W/CODE. | $0 | $0 | Nov 12, 2015 |
| Feb 7, 2008 | 34606463Y | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE NOTICE TO DOB PRIOR TO USE/INSTALL OUTRIGGER BEAMS IN CONNECTION WITH SUSPENDED SCAFFOLDS. | $500 | $0 | May 22, 2008 |
| Feb 7, 2008 | 34606464X | RESOLVE | Non-Hazardous | LOCATION OF SUS SCAFFOLD DOESN'T MATCH WITH APPROVED PLANS (REAR YARD). | $500 | $0 | May 22, 2008 |
| Feb 7, 2008 | 34606465H | RESOLVE | Non-Hazardous | 27-1046(E)(3) MORE THAN TWO WORKERS ON A TWO POINT SUSPENDED SCAFFOLD. | $500 | $0 | May 22, 2008 |
| Sep 17, 2007 | 38168843Y | RESOLVE | Hazardous | CEASE USE.79I11,84##,86U05.79I-VANDALIZED RIGHT HANDRAIL.84#-DO NOT USE THIS DEVICE AS A MEANS OF EGRESS AS PER 27-97... | $2,000 | $0 | Nov 8, 2007 |
| Jan 18, 2007 | 38163727Y | RESOLVE | Non-Hazardous | 86U05-PERFORM & FILE 2 YEAR TEST. | $350 | $0 | Mar 15, 2007 |
| Jan 18, 2007 | 38163726M | RESOLVE | Non-Hazardous | 86U05-PERFORM & FILE 2 YEAR TEST. | $350 | $0 | Mar 15, 2007 |
| Jan 18, 2007 | 38163735Y | RESOLVE | Non-Hazardous | 86U05-PERFORM AND FILE 2 YEAR TEST | $350 | $0 | Mar 15, 2007 |
| Jan 18, 2007 | 38163734M | RESOLVE | Non-Hazardous | 86U05-PERFORM & FILE 2 YEAR TEST. | $350 | $0 | Mar 15, 2007 |
| Jan 18, 2007 | 38163733K | RESOLVE | Non-Hazardous | 86U05-PERFORM & FILE 2 YEAR TEST. | $350 | $0 | Mar 15, 2007 |
| Jan 18, 2007 | 38163732Z | RESOLVE | Non-Hazardous | 86U05 PERFORM & FILE 2 YEAR TEST . | $350 | $0 | Mar 15, 2007 |
| Jan 18, 2007 | 38163731R | RESOLVE | Non-Hazardous | 86U05-PERFORM & FILE 2 YEAR TEST . | $350 | $0 | Mar 15, 2007 |
| Jan 18, 2007 | 38163730P | RESOLVE | Non-Hazardous | 86U05-PERFORM & FILE 2 YEAR TEST. | $350 | $0 | Mar 15, 2007 |
| Jan 18, 2007 | 38163729H | RESOLVE | Non-Hazardous | 86U05-PERFORM ALL FILE 2 YEAR TEST. | $350 | $0 | Mar 15, 2007 |
| Jan 18, 2007 | 38163728X | RESOLVE | Non-Hazardous | 86U05-PERFORM & FILE 2 YEAR TEST. | $350 | $0 | Mar 15, 2007 |
| Mar 4, 2004 | 38145952L | RESOLVE | Non-Hazardous | 83R#. 83R#-OPERATING AN EQUIPEMENT WITH AN EXPIRED TEMP CERTIFICATE EA 1121/99.CALL DEPT OF BLDG FOR APPONINTMENT 121... | $500 | $0 | Apr 22, 2004 |
| Jul 10, 2003 | 34401873H | RESOLVE | Hazardous | USING RIGGING EQUIPMENT WITH A MASTERS RIGGERS LICENSE. | $0 | $0 | Sep 16, 2004 |
| Jul 10, 2003 | 34401931R | RESOLVE | Non-Hazardous | LICENSED RIGGER FAILED TO SUPERVISE RIGGER WORK. LICENSED RIGGER DESIGNED AN UNQUALIFIED FOREMAN. | $0 | $0 | Jan 29, 2004 |
| Jul 10, 2003 | 34401932Z | RESOLVE | Hazardous | FAILURE TO COMPLY WITH CERTIFICATE OF ON SITE INSPECTION | $0 | $0 | Jan 29, 2004 |
| Aug 30, 2002 | 38125211X | RESOLVE | Non-Hazardous | 18Q03-18D06. 18-Q-03 THRU 5 18-D-06 PROPERLY SECURE FUB BSMT. | $0 | $0 | Oct 17, 2002 |
| Jul 25, 2002 | 38122833R | RESOLVE | Non-Hazardous | 73R05/74M07/53X07/ 73R OPERATING WITH EXPIRED TEMP FILE TO FINALIZE 74M INSTALL NYC DEVICE TAGS 53X DEMOLITION LIGHTS... | $250 | $0 | Sep 12, 2002 |
| Jul 25, 2002 | 38122834Z | RESOLVE | Non-Hazardous | 73R05/74M07/53X07/ 73R OPERATING WITH EXPIRED TEMP -FILE TO FINALIZE 74M INSTALL NYC DEVICE TAGS 53Y DEM LIGHTS INOPE... | $250 | $0 | Sep 12, 2002 |
| Jun 28, 2002 | 38124137M | RESOLVE | Non-Hazardous | 46Q07, 35Q07, 62Q07, 58O02, 59O02, 15P07, 50Q07, 37D06. 46- PROVIDE GUARD FOR HOIST CABLES AT MAIN MACHINE 35- PROVID... | $0 | $0 | Aug 15, 2002 |
| Jun 28, 2002 | 38124138Y | RESOLVE | Non-Hazardous | 53L11, 54D06, 50Y14, 74M07, 18Q03, 57Z14. 74 FIRE EXTINGUISHER 18 COVER ALL DOOR LOCKS 57 CLEAN PIT SEAL WATER LEAK 1... | $0 | $0 | Aug 15, 2002 |
| Aug 2, 2000 | 32019776X | RESOLVE | Non-Hazardous | 16,18A,18B,36,49 49A)27-793 FULTON ICS 015A HIGH PRESSURE BOILER MB#71767 1994 YEAR BUILT OPERATING WITHOUT AN EQUIPM... | $180 | $0 | Sep 28, 2000 |
| Sep 21, 1999 | 34228278R | RESOLVE | Non-Hazardous | INSTALLATION OF MECHANICAL EQUIPMENT WITHOUT FIRST OBTAINING AN EQUIPMENT. USE WORK PERMIT. LOCATION: ROOF TOP. OBTAI... | $0 | $0 | Mar 13, 2000 |
| Sep 20, 1999 | 34228277P | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT. 20% OF WORK COMPLETE. NOTED: A NEW SE STAIR &BRICK BULKHEAD UNDER CONSTRUCTION. NO PERMIT POST... | $500 | $0 | Dec 16, 1999 |
| May 25, 1999 | 34212097L | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT. NOTED OPEN STAIRS BETWEEN THIRD CELLAR THRU MEZZ LEVEL CONSTRUCTED. FIFTH FLOOR BATHROOMS REMO... | $500 | $0 | Jul 15, 1999 |
| Oct 2, 1998 | 34146696K | RESOLVE | Hazardous | OPERATION OF A BOOM TRUCK WITHOUT A OPERATIONS LICENSE. | $500 | $0 | Mar 4, 1999 |
| Oct 2, 1998 | 34146695Z | RESOLVE | Hazardous | OPERATION OF A BOOM TRUCK WITHOUT A CERTIFICATE OF OPERATION USE OF A BOOM TRUCK WITHOUT A HOISTING MACHINE OPERATION... | $6,500 | $0 | Mar 4, 1999 |
| Oct 16, 1997 | 34166459P | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT. NOTED:- OPEN STAIRWELL'S CONSTRUCTED BETWEEN 3 FLOOR'S CELLAR THRU 1ST MEZZAINE. 5 FL. BATHROO... | $350 | $0 | Jan 29, 1998 |
| Oct 16, 1997 | 34166460M | RESOLVE | Hazardous | REQUIRED MEAN'S OF EGRESS OBSTRUCTED. NOTED:- 5 FL. & 3 FL HAS EGRESS OBSTRUCTED BY LOCKS ON METAL WINDOW GATES, LEAD... | $0 | $0 | Jan 29, 1998 |
| Sep 24, 1997 | 34164906Z | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT. NOTED: OPENINGS PENETRATING FROM BLDG #502 THRUBLDG #504 LOCATED AT REAR OF BLDG ON FLRS BASEM... | $350 | $0 | Jan 29, 1998 |
| Sep 17, 1997 | 34164691K | RESOLVE | Hazardous | REQUIRED MEANS OF EGRESS OBSTRUCTED. NOTED:-5 FL & 4FL & FL. HAS EGRESS OBSTRUCTED BY. LOCK'S ON METAL WINDOW GATES L... | $0 | $0 | Jan 29, 1998 |
| Sep 17, 1997 | 34164690Z | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT NOTED: OPEN STAIRWELL'S CONSTRUCTED BETWEEN 3 FLOOR'S, CELLAR & BASEMENT. 1FL & MEZZANINE. 5 FL... | $350 | $0 | Jan 29, 1998 |
| Apr 20, 1996 | 38055427Y | RESOLVE | Non-Hazardous | 73R,. -73* EITHER RETURN TO SERVICE OR FILE AND OBTAIN PERMIT TO DISMANTLE DEVICE THEN HAVE DEVICE INSSPECTED BY THE ... | $0 | $0 | Jul 18, 1996 |
| Aug 2, 1995 | 34128727P | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT-WORK NOTE:ERECT NEW SPRIRAL STAIR OPEN CONCRETE FLOOR AT FIRST FLOOR TO INSTALL STAIR NEW KITCH... | $350 | $0 | Jan 11, 1996 |
| Dec 28, 1994 | 34106882H | RESOLVE | Non-Hazardous | FAILURE TO PRVIDE ADEQUATE ELEVATOR LANDING SIGNDS AT ALL 3 BANKS, INCINCORRECT BANK INDENTIFICATION. REMEDY -PROVIDE... | $500 | $0 | Feb 9, 1995 |
| Nov 7, 1994 | 38045662P | RESOLVE | Non-Hazardous | 22M,57O,5L,6L,74L,74A#,74BO. 74-REPAIR ANNUNCIATOR 74A-RENEW ALL STRAPS & CORDS FROM ALL HOISTWAY DOORS 74B-CLEAN CAR | $200 | $0 | Jan 5, 1995 |
| Nov 7, 1994 | 38045663R | RESOLVE | Non-Hazardous | 73X,5L,5L,6L,6L. | $200 | $0 | Jan 5, 1995 |
| Feb 2, 1994 | 38039908P | RESOLVE | Non-Hazardous | 75U,46T,73M,37G. 75 PERFORM 5YR. TEST PROPERLY DATE AND TAG DEVICE FORSAME AND FILE ELEV.3 FORM WITH THIS DEPT. B PRO... | $0 | $0 | Mar 17, 1994 |
| Feb 2, 1994 | 38039909R | RESOLVE | Non-Hazardous | 75U,05I,38G,73M. 75 PERFORM 5YR. TEST PROPERLY DATE AND TAG DEVICE FORSAME AND FILE ELEV#3 FORM WITH THIS DEPT. 73 PR... | $0 | $0 | Mar 17, 1994 |
| Feb 2, 1994 | 38039910Y | RESOLVE | Non-Hazardous | 75U,73M. 75 PERFORM 5YR. SAFETY TEST, PROPERLY DATE AND TAG DEVICE FORSAME AND FILE ELEV.#3 FORM WITH THIS DEPT. 73 P... | $0 | $0 | Mar 17, 1994 |
| Feb 2, 1994 | 38039911X | RESOLVE | Non-Hazardous | 75U,73M. 75 PERFORM 5YR. SAFETY TEST PROPERLY DATE AND TAG DEVICE FOR SAME AND FILE ELV.#3 FORM. 73 PROVIDE CITY # ID... | $0 | $0 | Mar 17, 1994 |
| Nov 23, 1993 | 34101289Y | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE ELEVATOR LANDING SIGNS AT EACH LANDING (BOTH FREIGHT AND PASSENGER). FAILURE TO PROVIDE FLOOR NUMB... | $0 | $0 | Jan 6, 1994 |
| Oct 12, 1988 | 34015737H | RESOLVE | Non-Hazardous | WORK DOES NOT CONFROM TO APPROVED PLANS-NON CORFORMING. REMEDY: CONFORM TO APPROVED PLAN. | $250 | $0 | Feb 9, 1989 |