ECB violations
81 Greene Street, Manhattan • Block 00486 • Lot 0019
13 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Oct 2, 2013 | 35021924K | RESOLVE | CLASS - 2 | OUTLETS ARE NOT PROVIDED EVERY 4'. KITCHEN COUNTER TOP 4 FLR APT: RECEPTACLE OUTLETS ARE NOT EVERY 4'. REMEDY: COMPLY... | $0 | $0 | Feb 13, 2014 |
| Oct 2, 2013 | 35021920N | RESOLVE | CLASS - 1 | ELECTRICAL WORK W/O A PERMIT. THE ENTIRE 4TH FLR APT: BRANCH CIRCUIT WIRING, RECEPTACLE OUTLETS, SWITCHES, LIGHTING F... | $400 | $0 | Feb 13, 2014 |
| Oct 2, 2013 | 35021921P | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE ARC-FAULT CIRCUIT INTERRUPTER (AFCI) PROTECTION IN DWELLING UNITS. THE ENTIRE FLR APT: LIVINGROOM,... | $200 | $0 | Feb 13, 2014 |
| Oct 2, 2013 | 35021922R | RESOLVE | CLASS - 2 | TAMPER-RESISTANT RECEPTACLES IN DWELLING UNITS. IN ALL AREAS SPECIFIEDIN 210.52, ALL 125 VOLT, 15 AND 20 AMPERE RECEP... | $200 | $0 | Feb 13, 2014 |
| Oct 2, 2013 | 35021923Z | RESOLVE | CLASS - 2 | SEC. EC 210.52(B) SPACING: RECEPTACLE SHALL BE INSTALLED SUCH THAT NO POINT MEASURED HORIZONTALLY ALONG THE FLR LINE ... | $150 | $0 | Feb 13, 2014 |
| Sep 19, 2013 | 32073711M | RESOLVE | CLASS - 2 | B154,51,50. 51- HIGH CO. EXHAUST 57 PPM AND CLIMBING SHUT DOWN. CEASE USE. REPAIR ALL HAZARDOUS CONDITION IMMEDIATELY... | $250 | $0 | Dec 5, 2013 |
| Sep 22, 2008 | 34700274X | RESOLVE | CLASS - 2 | FAILED TO OBTAIN A TEMPORARY CONSTRUCTION PERMIT PRIOR TO INSTALLATION/USE OF SIDEWALK SHED. REMEDY: OBTAIN TEMPORARY... | $500 | $0 | Apr 2, 2009 |
| Sep 22, 2008 | 34709525M | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE/POST SIGNS AT JOB SITE PURSUANT TO SUBSECTION. NOTED MEN ARE WORK ON SUSPENDED SCAFFOLD WITH NO CO... | $400 | $0 | Nov 13, 2008 |
| Sep 22, 2008 | 34709526Y | ACTIVE | CLASS - 1 | SEC.BC3314.6 THE FOOTINGS AND ANCHORAGE FOR EVERY SCAFFOLD SHALL BE SOUND + RIGID,CAPABLE OF CARRYING THE MAXIMUM LOA... | $1,600 | $0 | Nov 13, 2008 |
| May 1, 2007 | 34543548H | RESOLVE | Hazardous | WORK W/O PERMITS. WORK NOTED: AT ROOF LEVEL THERE EXIST (2) 14"X25' LONG STEEL I BEAMS SPANNING NORTH & SOUTH RESTING... | $800 | $0 | Jan 3, 2008 |
| May 1, 2007 | 34543549J | RESOLVE | Hazardous | SEC.27-375(H). FAILURE TO COMPLY W/ INTERIOR STAIR CONST OF A J-2 OCCUPANCY CLASSIFIED BLDG NOTE: 4 & 5 FL STAIRS (TH... | $0 | $0 | Jan 3, 2008 |
| Mar 8, 2007 | 34566008Z | ACTIVE | Non-Hazardous | OCCUPANCY CONTRARY TO THAT ALLOWED BY C OF O #90046. ILLEGAL OCCUPANC Y NOTED: A LEGAL 5 FL ARTIST STUDIO (JLWQ) ZONI... | $800 | $0 | Jan 3, 2008 |
| Aug 23, 1989 | 34030278N | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN EXTERIOR BRICK CHIMNEY AT ROOF PARAPET SOUTH WEST OUT OF PLUMB BRICKS MISSING AND MORTAR JOINTS A... | $0 | $0 | Oct 5, 1989 |