| Oct 30, 2017 | 35298685Y | RESOLVE | CLASS - 1 | UNSAFE STORAGE OF COMBUSTIBLE MATERIAL AND EQUIPMENT.AT ROOF LEVEL BEHIND BULKHEAD STORED PROPANE GAS IN 15LBS CYLIND... | $2,400 | $0 | Dec 21, 2017 |
| Oct 30, 2017 | 35298682Z | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY.AS 3,4 FLOOR(REAR CORRIDOR-EGRESS PASSAGEWAY)HAVING ARRANGE STORAGE F... | $250 | $0 | Dec 21, 2017 |
| Oct 30, 2017 | 35298683K | RESOLVE | CLASS - 1 | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY#(103909790T031.OBSERVED:ROOF LEVEL ILLEGALLY CONVE... | $1,200 | $0 | Dec 21, 2017 |
| Oct 30, 2017 | 35298684M | RESOLVE | CLASS - 1 | FAILURE TO COMPLY WITH OPENING PROTECTIVES REQUIREMENTS. DEFECTS NOTEDAT 2ND,3RD,4TH FLOORS HAVING FPSC DOORS SECURED... | $0 | $0 | Dec 21, 2017 |
| Aug 15, 2014 | 35096477Y | RESOLVE | CLASS - 2 | BC1205. FAILURE TO PROVIDE NATURAL LIGHT FOR HABITABLE ROOMS. NOTED: ON 4TH FLOOR ROOM #404 W/O DAYLIGHT AND VENTILAT... | $800 | $0 | Oct 2, 2014 |
| Aug 15, 2014 | 35096475K | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTIO DOCUMENTS AND/OR APPROVED AMENDMENTS. NONCONFORMING WORK NOTED: FULL HE... | $500 | $0 | Oct 2, 2014 |
| Aug 15, 2014 | 35096476M | RESOLVE | CLASS - 2 | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY #103909790.NOTED: ROOF OCCUIED AS RECREATION AREA ... | $1,200 | $0 | Oct 2, 2014 |
| Feb 24, 2014 | 35034249Z | RESOLVE | CLASS - 1 | SEC. BC 1008.1 FAILURE TO PROVIDE EGRESS DOOR READILY DISTINGUISHABLE.NOTED: MEANS OF EGRESS DOOR FROM CELLAR EATING,... | $1,600 | $0 | Apr 17, 2014 |
| Feb 24, 2014 | 35034250X | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. NOTED: FIRE EXIT STWYFROM CELLAR ACCESSORY USE AS FOOD PREPARATION &... | $1,200 | $0 | Apr 17, 2014 |
| May 21, 2013 | 35007145K | RESOLVE | CLASS - 1 | SEC. 1004.1.2 FAILURE TO COMPLY W/MAXIMUM FLOOR AREA REQUIREMENTS PER OCCUPANT LOAD. NOTED: ROOMS #401,402,439,334 EQ... | $1,600 | $0 | Jul 11, 2013 |
| May 21, 2013 | 35007144Z | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER,USE OF PROHIBITED DOOR HARDWARE. PER BC 1008.1.8;27-371(J). NOTED: ... | $0 | $0 | Jul 11, 2013 |
| May 21, 2013 | 35007142P | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/VACATE ORDER #16/2013. NOTED: AT TIME OF INSPECTION ROOMS #401,402,439,334 EQUIPPED,ARRANGED,OCCU... | $2,400 | $0 | Jul 11, 2013 |
| May 21, 2013 | 35007143R | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. NOTED: 1) IN ROOMS #402,439 ACCESS TO FIRE ESCAPE STAIRS PARTIALLY O... | $1,200 | $0 | Jul 11, 2013 |
| Feb 7, 2013 | 35006866X | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER USE OF PROHIBITED DOOR AND/OR HARDWARE PER BC 1008.1.8, 27-371(J) A... | $1,000 | $0 | Mar 28, 2013 |
| Feb 7, 2013 | 35006867H | RESOLVE | CLASS - 1 | WORK W/O A PERMIT. WORK NOTED: ERECT 2 ILLUMINATED DOUBLE FACED SIGNS @ FRONT OF PREMISES 1 (DEMOLISHED) EXISTING CUB... | $400 | $0 | Mar 28, 2013 |
| Feb 7, 2013 | 35006863K | RESOLVE | CLASS - 1 | OCCUPANCY CONTRARY TO THAT ALLOWED BY BLDG DEPT RECORDS. ILLEGAL OCCUPANCY NOTED 3RD & 4TH FLRS, ILLEGALLY CONVERTED ... | $2,400 | $0 | Jun 13, 2013 |
| Feb 7, 2013 | 35006868J | RESOLVE | CLASS - 1 | SEC. BC 715. FAILURE TO COMPLY W/OPENING PROTECTIVES NOTED: EXIT DOORSLEADING FROM 3 & 4 FLRS INTO INTERNAL STAIR ARE... | $400 | $0 | Mar 28, 2013 |
| Feb 7, 2013 | 35006864M | RESOLVE | CLASS - 1 | SEC. 1004.1.2, 1004.1.2. FAILURE TO COMPLY W/MAXIMUM FLR AREA REQUIREMENTS PER OCCUPANT LOAD NOTED: ROOMS #334,439,40... | $1,600 | $0 | Jun 13, 2013 |
| Feb 7, 2013 | 35006865Y | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. DEFECTS NOTED: 1) EXIT PASSAGEWAY LEAD IN FROM REAR FIRE ESCAPE TO... | $1,000 | $0 | Mar 28, 2013 |
| Nov 3, 2011 | 34933212H | RESOLVE | CLASS - 2 | ALTERED BLDG OCCUPIED W/O A VALID C/O. NOTED: PA EATING & DRINKING EST, OBSERVED IN OPERATION & PREMISES OCCUPIED. TC... | $0 | $0 | Dec 29, 2011 |
| Nov 3, 2011 | 34933211X | RESOLVE | CLASS - 2 | PA CONTRARY TO APPROVED CONSTRUCTION DOCUMENTS. NOTED: FURNITURE,I.E. A LARGE SOFA IS SITUATED NEXT TO & OBSTRUCTING ... | $0 | $0 | Dec 29, 2011 |
| Nov 3, 2011 | 34933210Y | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG. NOTED: ROLL DOWN STEEL GATE AT ENTRANCE TO PA IS REQUIRED TO BE LOCKED IN THE OPEN POSITION... | $1,000 | $0 | Dec 29, 2011 |
| Nov 3, 2011 | 34933209R | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. NOTED: EXIT PASSSAGE OBSTRUCTED BY FURNITURE, SOFA IN A PA, EATING &... | $1,200 | $0 | Dec 29, 2011 |
| Oct 3, 2010 | 34859697M | RESOLVE | CLASS - 2 | ALTERED CHANGED BLDG OCCUPIED W/O A VALID CERT OF CORRECTION AS PER 28-118.3.1-28-118.3.2 IN THAT C/O #10390970T008 H... | $250 | $0 | Dec 2, 2010 |
| Oct 13, 2007 | 34610110K | RESOLVE | Hazardous | FAILURE TO PROVIDE A SYSTEM OF AUTOMATIC SPRINKLERS WHERE REQUIRED.NO SPRINKLERS INSTALLED IN SLEEPING AREA.HEADS THA... | $400 | $0 | May 22, 2008 |
| May 13, 2005 | 38152348K | RESOLVE | Non-Hazardous | 83X# RESTORE DEVICE BACK TO SERVICE CALL THE DEPT OF BUILDING FOR A COMPLETE INSPECTION CAN BE MADE BY THIS DEPT. 1 2... | $2,500 | $0 | Jun 30, 2005 |
| Jan 20, 2005 | 38150596K | RESOLVE | Non-Hazardous | 83X10 83-RETURN UNIT TO SERVICE. | $180 | $0 | Mar 10, 2005 |
| Mar 10, 2003 | 38136563N | RESOLVE | Non-Hazardous | CEASE USE 16M12/ 48J11/ 47L11/ 67I11/ 54H12/ (16-M-12) NO SHAFT DOOR OR INTERLOCK AT BASEMENT FLOOR ( 48-J-11) HOIST ... | $500 | $0 | Apr 24, 2003 |
| Nov 25, 2002 | 38125670P | RESOLVE | Hazardous | 18N09-18M07-15M07. 18/N - INTERLOCK BYPASSED REMOVE. 18/M - BAS INTERLOCK MISSING PROVIDE. 15/M BAS SHAFT DOOR MISSSI... | $1,250 | $0 | Jun 12, 2003 |
| Jul 8, 2002 | 38124144K | RESOLVE | Hazardous | CEASE USE 15M07/ 18M07/ CEASE USE OF DEVICE UNTIL HOISTWAY DOOR AND INTER LOCKS PROVIDED. CALL 646-248-8740 WHEN READ... | $1,250 | $0 | Nov 14, 2002 |
| Jun 3, 2002 | 38123854K | RESOLVE | Hazardous | 15M07/18M07. 15,18M07 CEASE USE OF THIS DEVICE UNTIL BASEMENT HATCH DOOR AND INTERLOCK ARE PROVIDED. CALL 646 248 874... | $2,500 | $0 | Aug 22, 2002 |
| Oct 4, 1995 | 38051814X | RESOLVE | Non-Hazardous | 27L, 39#, 39-SHEAVE ON MACHINE OEVERHEAD BEAVES (NOT DRUM SHEAVE) | $0 | $0 | Dec 14, 1995 |