ECB violations
37-39 King Street, Manhattan • Block 00520 • Lot 0051
15 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jan 30, 2025 | 39136985J | RESOLVE | CLASS - 1 | VF. CEASE USED,,, CAR DOOR RESTRICTOR NOT WORKING. REPAIR ... RE INSPECTION REQUIRED. | $1,250 | $0 | Apr 10, 2025 |
| Sep 27, 2023 | 35667038Z | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED IN THE BASEMENT/CELLAR EXCESSIVE COMBUSTIBLE STORAGE ... | $1,250 | $0 | May 28, 2024 |
| Sep 27, 2023 | 35667037R | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING CODE-COMPLIANT MANNER. OBSERVED IN BASEMENT/CELLAR GAS PIPING IS BEING SUPPORTED WITH PL... | $1,250 | $0 | May 28, 2024 |
| Jun 8, 2023 | 39517599K | RESOLVE | CLASS - 1 | AT TIME OF INSPECTION OF A 5 STOREYS ALTERATION OF OCCUPIED APARTMENTS BUILDING UNDER CONSTRUCTION I OBSERVED INTERIO... | $250 | $0 | Aug 17, 2023 |
| Sep 12, 2019 | 38271123L | RESOLVE | CLASS - 2 | 16.L.10,39.O.02,59.M.7,57.BB.7=16-L-10 HOISTWAY DOOR ON 5 FLOOR I NOT CLOSING ENOUGH FOR CAR TO TAKE OFF DERECTIVE RE... | $625 | $0 | Feb 13, 2020 |
| Jul 31, 2019 | 39006850R | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE APPROVED CONSTRUCTION DOCUMENTS AT JOB SITE AT TIME OF INSPECTION. NOTED: WORK IN PROGRESS IN APT ... | $0 | $0 | Sep 19, 2019 |
| Jan 14, 2019 | 35366165M | RESOLVE | CLASS - 2 | FAILURE TO POST OR DISTRIBUTE SAFE CONSTRUCTION BILL OF RIGHTS NOTED:@ TIME OF INSPECTION OBSERVED THAT THE SAFE CONS... | $0 | $0 | Apr 11, 2019 |
| Jan 14, 2019 | 35366164K | RESOLVE | CLASS - 2 | FAILURE TO DISTRIBUTE OR POST NOTICE OF TENANT PROTECTION PLAN.NOTED:AT TIME OF INSPECTION OBSERVED WORKERS IN APT 2C... | $0 | $0 | Apr 11, 2019 |
| Aug 23, 2018 | 35333048M | RESOLVE | CLASS - 2 | FAILURE TO SAFEGUARD PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. NOTED: INTERIOR RENOVATION AT APT#4G UNDER JOB#140... | $0 | $0 | Apr 4, 2019 |
| Jul 7, 2018 | 35322742Z | RESOLVE | CLASS - 2 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTIONOPERATIONS.NOTED:CONSTRUCTION OPERATIONS IN APT... | $5,000 | $0 | Mar 7, 2019 |
| Dec 30, 2015 | 35170686N | RESOLVE | CLASS - 2 | 3307.6.5 FAILURE TO MAINTAIN ADEQUATE ILLUMINATION BENEATH SIDEWALK SHED AS REQUIREC BY CODE. NOTE: SIDEWALK SHED ERE... | $0 | $0 | Feb 18, 2016 |
| Oct 9, 2014 | 35100523P | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTIOJ DOCUMENTS. NOTED: AT TIME OF INSPECTION SIDEWALK SHED HAD BEEN BUILT T... | $0 | $0 | Dec 4, 2014 |
| Jun 7, 2011 | 38216097P | RESOLVE | CLASS - 2 | 40B07 05M07 76I11 61M07 40-PROVIDE VENTILATION FOR MACHINE ROOM 5-PROVIDE DOOR ZONE RESTRICTOR 76-TAIL ROPE KINKED RE... | $0 | $0 | Jul 28, 2011 |
| Mar 29, 2005 | 38151860P | RESOLVE | Non-Hazardous | 84M07/21O02/ 84-M-7-PROVIDE CAPACITY PLATE IN CAB | $0 | $0 | May 19, 2005 |
| Oct 19, 1995 | 38044344P | RESOLVE | Non-Hazardous | 171,36P,. | $200 | $0 | Dec 28, 1995 |