ECB violations
13-19 University Place, Manhattan • Block 00548 • Lot 0009
29 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jan 27, 2023 | 35653951L | RESOLVE | CLASS - 1 | FAILED TO SUBMIT REPORT OT DEPT OF AN INCIDENT THAT RESULTED IN A FATALITY OR INJURY.NOTE A WORKER FELL OFF GOOSE NEC... | $2,500 | $0 | Jun 6, 2024 |
| Dec 20, 2022 | 39510594J | RESOLVE | CLASS - 1 | AT TIME OF INSPECTION OBSERVED SUSPENDED SCAFFOLDING AT EXPOSURE # 3 UNSAFE LIFE LINES, NOT PROTECTED FROM ABRASION A... | $0 | $0 | Nov 16, 2023 |
| Dec 20, 2022 | 39510595L | RESOLVE | CLASS - 1 | AT TIME OF INSPECTION, OBSERVED AT EXPOSURE # 3 ERECTED SUSPENDED SCAFFOLDING SET UP IN THE BULK HEAD, WORK NOT CONFO... | $2,500 | $0 | Nov 16, 2023 |
| Dec 20, 2022 | 39510602K | RESOLVE | CLASS - 1 | AT INSPECTION OBSERVED A SUSPENDED SCAFFOLDING AT EXPOSURE 3, UPON REQUEST FOR THE RIGGING FOREMAN FOR CODE COMPLIANC... | $2,500 | $0 | Nov 16, 2023 |
| Dec 20, 2022 | 39510589P | RESOLVE | CLASS - 1 | AT TIME OF INSPECTION, OBSERVED AT EXPOSURE # 3 "C" HOOKS NOT FULLY BLOCKED TO PROTECT THE EXISTING PARAPET WALLS SUS... | $0 | $0 | Nov 16, 2023 |
| Dec 19, 2022 | 39075966H | RESOLVE | CLASS - 1 | RESPONSIBILITIES FOR SAFETY: FAILURE TO INSTITUTE ADEQUATE SAFETY MEASURES. FACADE WORK BEING DONE AT 19 UNIVERSITY P... | $0 | $0 | Jun 15, 2023 |
| Nov 15, 2013 | 35031575K | ACTIVE | CLASS - 1 | 3314.4.1 UPON COMPLETION OF THE INSTALLATION OF THE SCAFFOLD, AN INSPECTION REPORT WORKING THAT THE SCAFFOLD HAS BEEN... | $1,600 | $0 | May 15, 2014 |
| Nov 15, 2013 | 35031482L | ACTIVE | CLASS - 2 | WORK DOES NOT CONFORM AO APPROVED CONSTRUCTION DOCUMENTS. NOTED: INSTALLATION OF SUPPORTED SAFFOLD AT REAR ELEVATION,... | $2,500 | $0 | Jan 2, 2014 |
| Nov 15, 2013 | 35031477R | ACTIVE | CLASS - 1 | 3314.5 PLATFORM CONSTRUCTION. NOTED: ALL WORK (LEVERS) ON PIPE SCAFFOLD, NOT FULLY PLANKED AND EXPOSED OPEN AREAS THR... | $8,000 | $0 | May 15, 2014 |
| Nov 15, 2013 | 35031475N | ACTIVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATION NOTED:A FATALITY RESULTED IN A WORKER ... | $12,000 | $0 | May 15, 2014 |
| Nov 15, 2013 | 35031480H | ACTIVE | CLASS - 1 | INADEQUATE SAFETY MEASURES: OPERATION OF HOISTING EQUIPMENT IN UNSAFE MANNER NOTED:BETA MA HOIST INSTALLED ON SUPPORT... | $24,000 | $0 | May 15, 2014 |
| Nov 15, 2013 | 35031481J | ACTIVE | CLASS - 1 | USE OF SUPPORTED SCAFFOLD W/O A SCAFFOLD USER CERTIFICATE NOTED: TWO WORKERS ON SUPPORTED SCAFFOLD W/O SCAFFOLD USER ... | $8,000 | $0 | May 15, 2014 |
| Nov 15, 2013 | 35031483N | ACTIVE | CLASS - 1 | 3314.4.3 INSPECTIONS: ALL SCAFFOLDS SHALL BE INSPECTED DAILY BEFORE EACH USE. NOTED:AT TIME OF INSPECTION NO DAILY LO... | $8,000 | $0 | May 15, 2014 |
| Nov 15, 2013 | 35031484P | ACTIVE | CLASS - 1 | 3314.8 GUARD RAIL SYSTEMS AND TOEBOARDS NOTED:INADEQUATE GUARD RAIL SYSTEM AND TOEBOARDS ON SUSPENDED ROPE SCAFFOLD, ... | $1,600 | $0 | May 15, 2014 |
| Nov 15, 2013 | 35031485R | ACTIVE | CLASS - 1 | NO RECORD OF DAILY INSPECTION OF SUSPENDED SCAFFOLD PERFORMED BY AUTHORIZED PERSON ON SITE NOTED:NO DAILY RECORD OF I... | $2,400 | $0 | May 15, 2014 |
| Nov 15, 2013 | 35031478Z | ACTIVE | CLASS - 1 | 3314.8 GUARD RAIL SYSTEM AND TOEBOARDS NOTED:AT ALL WORK (LEVERS), GUARD RAIL SYSTEM & TOEBOARDS ARE MISSING THROUGHO... | $8,000 | $0 | May 15, 2014 |
| Nov 15, 2013 | 35031479K | ACTIVE | CLASS - 1 | 3314.13.1 BRACING: NOTED: FRAMES & PANELS SHALL BE BRACE BY CROSS BRACES, CROSS BRACES MISSING AT WORK LEVER, HOIST A... | $8,000 | $0 | May 15, 2014 |
| Nov 15, 2013 | 35031476P | ACTIVE | CLASS - 1 | 3314.6 SAFE POINTS OF ANCHORAGE: NOTED: AT TIME OF INSPECTION OBSERVED TIES FROM SUPPORTED SCAFFOLD HAVE BEEN COMPROM... | $8,000 | $0 | May 15, 2014 |
| Oct 13, 2012 | 34952574Z | RESOLVE | CLASS - 2 | SEC. 3307.6 SIDEWALK SHED SIGNS. NOTED: AT TIME OF INSPECTION PERMIT HOLDER FAILED TO MEET REQUIREMENTS OF SECTION 33... | $400 | $0 | Nov 29, 2012 |
| Sep 27, 2000 | 38107100Y | RESOLVE | Non-Hazardous | 73##-RETURN TO SERVICE,FOR FULL INSPECTION. | $0 | $0 | Nov 16, 2000 |
| Sep 27, 2000 | 38107099X | RESOLVE | Non-Hazardous | 73##-RETURN TO SERVICE. | $0 | $0 | Nov 16, 2000 |
| Jul 22, 1998 | 34179023R | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN EXTERIOR BUILDING WALL. NOTED: BRICK WALL AT EAST/SIDE SPALLING & CRACKED & FALLING ONTO ADJOININ... | $350 | $0 | Jan 30, 2001 |
| May 28, 1997 | 34154410X | RESOLVE | Non-Hazardous | WORK DOES NOT CONFORM TO APPROVED PLAN DATED 10.12.94 PRIMARY ENTRANCE DOOD NOT HANDICAP ACCESSIBLE STEP NOT SHOWN ON... | $125 | $0 | Aug 14, 1997 |
| Mar 13, 1996 | 38054766Y | RESOLVE | Unknown | 75U. | $0 | $0 | May 2, 1996 |
| Mar 13, 1996 | 38054767X | RESOLVE | Unknown | 75U. | $0 | $0 | May 2, 1996 |
| Apr 5, 1991 | 34049940Z | RESOLVE | Non-Hazardous | USE OF PROHIBITED DOOR ROLL DOWN GATE ON SECOND MEANS OF EGRESS REMEDY REMOVE ILLEGAL DOOR | $0 | $0 | May 23, 1991 |
| Oct 1, 1990 | 34044452R | RESOLVE | Hazardous | FAILURE TO HAVE APPROVED PA PLANS AVAILABLE FOR INSPECTION REMEDY:PROVIDE APPROVED PA PLANS | $250 | $0 | Nov 15, 1990 |
| Nov 13, 1989 | 34033823N | RESOLVE | Hazardous | FAILURE TO HAVE APPROVED PA PLANS AVAILABLE FOR INSPECTION REMEDY PROVIDE APPROVED PLAN FOR INSPECTION EMERGENCY LIGH... | $500 | $0 | Dec 28, 1989 |
| Sep 26, 1988 | 30031294M | RESOLVE | Hazardous | OPERATION OF A PA WITHOUT A VALID C OF O. REMEDY: OBTAIN A PERMIT FAILURE TO HAVE APPROVED PA PLANS AVAILAVE FOR INSP... | $35 | $0 | Nov 17, 1988 |