| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Nov 16, 2018 | 35365165H | RESOLVE | CLASS - 1 | FAILURE TO TAKE AND PROVIDE ADEQUATE SAFETY MEASURES. WHERE REQUIRED TO SECURE AND PROTECT PUBLIC SAFETY. FROM DOCUME... | $0 | $0 | Jan 10, 2019 |
| Jan 6, 2017 | 38252337N | RESOLVE | CLASS - 2 | 8V1,1L10,10H11,16J1,56Y2,56Y13,77K10,17H11. (8V)CAR FLR TO LANDING SILL NOT LEVEL ADJUST. (1L)EMERGENCY STOP SWITCH D... | $0 | $0 | Feb 23, 2017 |
| Dec 22, 2016 | 38251364Y | RESOLVE | CLASS - 1 | 97X17,40O02. THE ONLY ELEVATOR IN BLDG IS OUT OF SERVICE.UPON INSPEC TION THE DEVICE IS FOUND TO BE OUT OF SERVICE CR... | $0 | $0 | Apr 6, 2017 |
| Nov 3, 2016 | 38254642Z | RESOLVE | CLASS - 1 | 97X10:FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER,SERVICE EQUIPMENT ELEVATOR PER BC3001.2&27-987 DOB RECORDS SH... | $1,000 | $0 | Jun 22, 2017 |
| Jun 4, 2013 | 38227554P | RESOLVE | CLASS - 2 | B251:39O02,37L10,02X10.02S:2-WAY COMMUNICATION INOPERABLE.37L:RUN/STOP SWITCH CHECKED DURING INSPECTION-SHUTDOWN ELEV... | $500 | $0 | Aug 29, 2013 |
| Mar 5, 2012 | 38220844L | RESOLVE | CLASS - 2 | 40Y02,56Y13,02X10,59Y02,10D06. 02X- 2 WAY COMMUNICATION INOPERABLE. | $0 | $0 | Apr 19, 2012 |
| Feb 15, 2012 | 38220826H | RESOLVE | CLASS - 2 | 21D01 42J01 56Y13 52O02 59O02 70Y02 64B07. 21D-SECURE BASEMENT INTERLOCK. 42J-ARCING FROM CONTROLLER & MACHINE LIMITS... | $250 | $0 | Apr 5, 2012 |
| Mar 28, 2008 | 34684107L | RESOLVE | Non-Hazardous | FAILURE TO FILE AN AMENDED 6TH ROUND REPORT ACCEPTABLE TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRI... | $700 | $0 | Jun 12, 2008 |
| Mar 18, 2008 | 38182806X | RESOLVE | Non-Hazardous | 55Y13. 55Y10 EXCESSIVE OIL LEAK SEAL MACHINE | $2,500 | $0 | May 8, 2008 |
| Feb 27, 2008 | 38182256K | RESOLVE | Hazardous | 57B10.08V01.84B01. 57B10 UPON NY ARRIVAL I OBSERVED REAR BOX WAS SMOKING NO OIL CEASE USE 08V01 CAR FL TO LANDING SIL... | $800 | $0 | Sep 11, 2008 |
| Feb 21, 2008 | 38181937L | RESOLVE | Non-Hazardous | 83L# 83 RETURN DEVICE TO SERVICE FOR F-11 INSPECTION | $180 | $0 | Sep 11, 2008 |
| Sep 19, 2007 | 34418513P | RESOLVE | Hazardous | LOCAL LAW REPORT FILED AS "UNSAFE", UNSAFE CONDITION EXITS AND NO MEASURES TAKEN TO SECURE SAFETY OF PUBLIC AS PER 27... | $700 | $0 | Nov 8, 2007 |
| Nov 24, 2006 | 34546289X | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN.NOTED:NO DRAINAGE FOR ACCUMULATION OF STORM WATER COLLECTED @ PENTHOUSE #1 TERRACE.DRAINAGE SYSTE... | $200 | $0 | Jan 11, 2007 |
| Jul 5, 2006 | 38160134P | RESOLVE | Non-Hazardous | 55-Y-13,44-H-10,36-D-06,31-B-12/55-HOIST MACHINE OIL LEAK;CLEAN & SEALMACHINE/44-WORN BEARINGS/PARTS ON GOVERNOR;REPA... | $0 | $0 | Aug 24, 2006 |
| Dec 3, 2004 | 38150309Z | RESOLVE | Non-Hazardous | 21J01/85BB05/58B11/55Y13/05B01/84P16 21-CAR CLIPPING DOOR LOCK ROLLER 85- CURRENT TAG SHOWS 7/99 58-OIL ON BRAKE LINI... | $350 | $0 | Jan 20, 2005 |
| Aug 27, 2004 | 34451398N | RESOLVE | Hazardous | FAILURE TO MAINTIAN BLDG-HAZARDOUS BROKEN & CRACKED PLASTER CEILING & WALLS IN APT 1C. 1C IS A 1 BEDROOM APT.LIVING R... | $0 | $0 | Oct 14, 2004 |
| Apr 1, 2004 | 38146398H | RESOLVE | Non-Hazardous | 08J01,17J01,30Q06,30Q06,31J01,36O02,38O02,44E09,52O02,59B07,64L07,83O02. 08-ADJUST 17-ADJUST WHERE NECESSARY 30-COVER... | $180 | $0 | May 20, 2004 |
| Feb 2, 2004 | 38144537J | RESOLVE | Non-Hazardous | 08V01,17H11,16M11,10M11,36O02,36I10,63B07,84R#. 17H11-REPLACE WORN GIB ON 9TH FLOOR. 16M11- REPLACE MISSING MO ROLLER... | $180 | -$180 | Mar 18, 2004 |
| Dec 5, 2003 | 38143582Y | RESOLVE | Non-Hazardous | 17J01,34Q07,36P07,36E09,38O02,64L10,69M07,83BB12. 17-1ST FLOOR WHERE NECESSARY 34 PROVIDE COVERS IN SHAFTYWAY WHEREVE... | $180 | $0 | Jan 22, 2004 |
| Sep 23, 2003 | 38142326K | RESOLVE | Non-Hazardous | 83X#. 83X RETURN DEVICE BACK TO SERVICE FOR A COMPLETE INSPECTION CAN BE MADE BY THIS DEPT. | $180 | $0 | Nov 13, 2003 |
| Sep 12, 2003 | 38141815R | RESOLVE | Hazardous | 17H10/28D06/33O02/36#16/38O02/53BB05/66O02/20I11 17-H BASEMENT DOOR 28-D-DOOR OPERATOR COVER OFF 36# NO ACCESS TO OVE... | $180 | $0 | Oct 30, 2003 |
| Jan 18, 2002 | 34291334Y | RESOLVE | Hazardous | FAILURE TO MAINTAIN EXTERIOR BUILDING WALL NOTED THE SOUTH ELEVATION -2ND AND 7TH FLOOR BALCONIES,SEVERAL UNSECURED P... | $800 | $0 | Mar 7, 2002 |
| May 26, 1999 | 38083850J | RESOLVE | Non-Hazardous | 57Z,75U,08V,22D,46B. PIT WATER COMPITION, PERFORM 5 YEAR TEST AND TAG, ADJUST LEVELING SECURE TOP EMERGENCY EXIT COVE... | $180 | $0 | Aug 12, 1999 |
| Mar 7, 1996 | 38054916K | RESOLVE | Non-Hazardous | 75U. | $200 | $0 | May 23, 1996 |
| Jul 24, 1991 | 38014834K | RESOLVE | Non-Hazardous | 17I,17M,58L,8J,17-M-7 PROVIDE GRILLS | $1,000 | $0 | Oct 24, 1991 |