ECB violations
1-11 East 8 Street, Manhattan • Block 00566 • Lot 0001
44 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Mar 17, 2025 | 39538070N | ACTIVE | CLASS - 2 | AT TIME OF INSPECTON I OBSERVED SIDEWALK SHED INSTALLED ON EXPOSURE # 1 AND 2 WITHOUT SIGNS OR PROJECT INFORMATION PA... | $1,250 | $0 | Nov 7, 2025 |
| Aug 27, 2024 | 39531871L | ACTIVE | CLASS - 2 | AT THE TIME OF INSPECTION UPON REQUEST TO SEE & VERIFY DOCUMENTS NON WAS PROVIDED OR PRESENTLY ONSITE AS PER BC CODE ... | $1,250 | $0 | Mar 27, 2025 |
| Aug 27, 2024 | 39531870J | RESOLVE | CLASS - 2 | AT THE TIME OF INSPECTION I OBSERVED TIEBACK INSTALLED AT EXPOSURE 3 GOING OVER PARAPET WALL CONTRARY TO THE APPROVED... | $0 | $0 | Oct 31, 2024 |
| Sep 9, 2022 | 39506121H | RESOLVE | CLASS - 2 | AT THE TIME OF MY INSPECTION OF A 20 STORY FACADE ALT I OBSERVED THAT APPROXIMATLY 180 FEET OF SIDEWALK SHED AT EXPOS... | $1,250 | $0 | Oct 27, 2022 |
| Mar 25, 2021 | 35541037N | RESOLVE | CLASS - 2 | FAILURE TO POST OR DISTRIBUTE SAFE CONST BILL OF RIGHTS.NOTE ATOI OBSERVED WORK BEING PERFORMED UNDER AFOREMENTIONED ... | $1,250 | $0 | Aug 26, 2021 |
| Mar 25, 2021 | 35541038P | RESOLVE | CLASS - 2 | FAILURE TO POST&DISTRIBUTE TENANT PROTECTION PLAN NOTE:ATOI OBSERVED WORK BEING PERFORMED IN APT18C UNDER AFOREMENTIO... | $1,250 | $0 | Aug 26, 2021 |
| Mar 25, 2021 | 35541036L | RESOLVE | CLASS - 1 | 28-201.1 INADEQUATE TENANT PROTECTION PLAN NOTE:ATOI OBSERVED WORK BEING PERFORMED UNDER AFOREMENTIONED JOB#.SUBMITTE... | $2,500 | $0 | Aug 26, 2021 |
| Jul 20, 2020 | 35382267N | RESOLVE | CLASS - 2 | @TIME OF INSPECTION, OBSERVED ONGOING CONST ACTIVITES CONTRARY TO MAYORS EMERGANCY EXECUTIVE ORDER 120 &, SUBSEQUENT ... | $0 | $0 | Sep 24, 2020 |
| Jan 6, 2020 | 35432483K | RESOLVE | CLASS - 2 | FAILURE TO DISTRIBUTE OR POST A NOTICE OF TENANT PROTETCTION PLAN TPP AT THE TIME OF INSPECTION OBSERVED ACTIEV CONST... | $0 | $0 | Mar 12, 2020 |
| Jan 6, 2020 | 35432484M | RESOLVE | CLASS - 2 | FAILURETO DISTRIBUTE OR POST A NOTICE OF THE SAFE CONSTRUCTION BILL OF RIGHTS IN ACCORDANCE WITH TEH HOUSING AND MAIN... | $0 | $0 | Mar 12, 2020 |
| Dec 18, 2019 | 35433342L | RESOLVE | CLASS - 1 | UNQUALIFIED WORKER PERFORMING WORK ON SCAFFOLD. NOTED: ON A SUSPENDED C-HOUR SCAFFOLD INSTALLED UNDER SUPERVISION OF ... | $0 | $0 | Apr 22, 2021 |
| Dec 18, 2019 | 35433341J | RESOLVE | CLASS - 1 | BC 3314.6.1 FAILURE TO MAINTAIN SAFEGUARD(NO ADEQUATE GUARDRAILS OR ANCHOR)NOTED ON A 12TH STY BLDG A C-HOUR SCAFFOLD... | $0 | $0 | Apr 22, 2021 |
| Dec 3, 2013 | 35084326Z | RESOLVE | CLASS - 3 | FAILURE TO MAINTAIN NOTED EXIT SIGN AT 1ST,FLOOR OF PARKING GARAGE MISSING AT LEFT SIDE EXIT TOWARDS REAR. RMDY: PROV... | $0 | $0 | Jan 23, 2014 |
| Nov 26, 2011 | 34933460R | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: AT GARAGE, NO ILLUMINATED EXIT SIGN AT BOTH EMERGENCE EXITS... | $0 | $0 | Jan 12, 2012 |
| Mar 25, 2010 | 34745049Z | RESOLVE | CLASS - 1 | WORK W/O A PERMIT. BASED ON PHYSICAL OBSERVATION OF BASEMENT IN ABOVE ADDRESS,I WITNESSED PLUMBING WORK BEING DONE W/... | $0 | $0 | Jun 17, 2010 |
| Mar 19, 2010 | 34832400M | RESOLVE | CLASS - 1 | INADEQUATE SAFETY MEASURE:OPERATION OF HOISTING EQUIPMENT IN AN UNSAFEMANNER.NOTED:3-OUT OF 4-SAFETY HARNESSES WERE N... | $4,800 | $0 | Oct 21, 2010 |
| Mar 19, 2010 | 34832401Y | RESOLVE | CLASS - 1 | FAIL TO PERFORM SAFE/PROPER INSPECTION OF SUSPENDED SCAFFOLD.NOTED:3-OUT OF 4-SAFETY HARNESSES IN USE ARE DEFECTIVE &... | $10,000 | $0 | Oct 21, 2010 |
| Mar 19, 2010 | 34832402X | RESOLVE | CLASS - 1 | LICENSED RIGGER FAILED TO ENSURE SCAFFOLD WORKERS MET MINIMUM REQUIREMENTS.NOTED:4-OUT OF 6-SUSPENDED SCAFFOLD WORKER... | $1,600 | $0 | Oct 21, 2010 |
| Nov 30, 2009 | 34815158Z | RESOLVE | CLASS - 1 | FAIL TO PERFORM A SAFE/PROPER INSPECTION OF SUSPENDED SCAFFOLD. NOTED:LIFELINES & TIE BACKS ARE SECURED TO SAME DOUBL... | $10,000 | $0 | Jan 31, 2011 |
| Nov 30, 2009 | 34786397X | RESOLVE | CLASS - 1 | FAIL TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPS UPON INSPECTION AS NOTED ON ACTIVE CONST SITE T... | $2,400 | $0 | Jul 8, 2010 |
| Nov 30, 2009 | 34786398H | RESOLVE | CLASS - 1 | FAIL TO INSTITUTE & MAINTAIN SAFETY EQUIP MEASURES OR TEMP CONST NO HANDRAILS ON A RAMP RISING-APPROX 3FT FROM ONE PL... | $1,000 | $0 | Jul 8, 2010 |
| Nov 30, 2009 | 34786392R | RESOLVE | CLASS - 1 | SEC. 3310.6. DESIGNATION OF SITE SAFETY MANAGER: UPON INSPECTION AS NOTED ON ACTIVE CONSTRUCION SITE THERE WAS NO SIT... | $1,600 | $0 | Jul 8, 2010 |
| Nov 30, 2009 | 34786394K | RESOLVE | CLASS - 1 | FAILURE TO STORE COMBUSTIBLE/COMPRESSED GAS IN A SAFE AND PROPER MANNER. UPON INSPECTION AS NOTED THERE WERE 2# PLAST... | $1,600 | $0 | Jul 8, 2010 |
| Nov 30, 2009 | 34786395M | RESOLVE | CLASS - 1 | FAIL TO MAINTAIN ADEQUATE HOUSEKEEPING AS PER SECTION REQUIREMENTS:UPON INSP AS NOTED ON ACTIVE CONST SITE THERE WAS ... | $2,400 | $0 | Jul 8, 2010 |
| Nov 30, 2009 | 34815159K | RESOLVE | CLASS - 1 | LICENSED RIGGER FAILED TO NAME & DESIGNATED FOREMAN. NOTED AT TIME OF INSPECTION THERE IS NO FOREMAN ON SITE. MAN CLA... | $1,600 | $0 | Jan 31, 2011 |
| Nov 30, 2009 | 34815160H | RESOLVE | CLASS - 1 | FAIL TO SAFEGUARD ALL PERSONS/PROPERTY AFFECTED BY CONST OPERATIONS. NOTED MEN WORKING ON SIDEWALK SHED AT POINTS IS ... | $2,400 | $0 | Jan 31, 2011 |
| Nov 30, 2009 | 34815161J | RESOLVE | CLASS - 2 | SIDEWALK SHED DOES NOT MEET BLDG CODE SPECIFICATIONS. NOTED: SHED AT EXP #2 OVER ENTRANCE TO PARKING GARAGE HAS NO PR... | $2,400 | $0 | Jun 4, 2010 |
| Nov 30, 2009 | 34786391P | RESOLVE | CLASS - 1 | SEC. 3310.3. FAILURE TO PROVIDE SITE SAFETY PROGRAM/PLAN - UPON INSPECTION AS NOTED ON ACTIVE CONSTRUCTION SITE, THE ... | $0 | $0 | Jul 8, 2010 |
| Nov 30, 2009 | 34786393Z | RESOLVE | CLASS - 2 | SEC. 3301.2. FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION. UPON INSPECTION, AS N... | $4,000 | $0 | Jul 8, 2010 |
| Nov 30, 2009 | 34786399J | RESOLVE | CLASS - 1 | WRK W/O A PERMIT UPON INSP AS NOTED:ON AN ACTIVE CONST SITE THERE WAS AN ALTERATION UNDERWAY W/SUSPENDED SCAFFOLDS IN... | $1,600 | $0 | Jul 8, 2010 |
| Nov 30, 2009 | 34815157R | RESOLVE | CLASS - 1 | INADEQUATE SAFETY MEASURES: OPERATION OF HOISTING EQUIPMENT IN AN UNSAFE MANNER. NOTED THERE IS APPROX 10' TO 30' OF ... | $4,800 | $0 | Jan 20, 2011 |
| Nov 30, 2009 | 34786396Y | RESOLVE | CLASS - 1 | FAIL TO SAFEGUARD PUBLIC & PROPERTY AFFECTED BY CONST OPS:UPON INSP ASNOTED ON ACTIVE CONST SITE THERE WAS NO 2ND MEA... | $2,400 | $0 | Jul 8, 2010 |
| Jan 31, 2008 | 34606316Y | RESOLVE | Hazardous | INSTALLED EQUIPMENT DOES NOT MATCH TO APPROVED PLANS MISSING TIEBACK ON MATERIALS HOIST. | $500 | $0 | Nov 6, 2008 |
| Dec 7, 2001 | 38119447L | RESOLVE | Non-Hazardous | 18M12/ 24H12/ 74O02/ 15M07/ 18 - BASEMENT DOOR LOCCK COVER. 34 REPLACE WORN TRAVELING CABLES 74 CLEAN CAR TOP PATCH H... | $0 | $0 | Jan 24, 2002 |
| Dec 7, 2001 | 38119448N | RESOLVE | Non-Hazardous | 34H12/ 41M07/ 22D06/ 44M06/ 50O02/ 34 - REPLACE WORN TRAVELING CABLE 41 - COVER MISSING 22 - SECURE TOP OF CAR EXIT C... | $0 | $0 | Jan 24, 2002 |
| Dec 7, 2001 | 38119449P | RESOLVE | Non-Hazardous | 46B15/ 25M07/ 46 SHORTEN HOIST CABLES 25 PROVIDE COVER | $0 | $0 | Jan 24, 2002 |
| Nov 2, 2000 | 38109429Z | RESOLVE | Non-Hazardous | 48B15,57O02. | $0 | $0 | Dec 21, 2000 |
| Nov 2, 2000 | 38109430X | RESOLVE | Hazardous | 01X11. CEASEUSE UNITL STOP SWITCH HAS BEEN REPAIRED CALL 212-312-8738 WHEN RETURNING CAR TO SERVICE. | $500 | $0 | Dec 21, 2000 |
| Jun 9, 1998 | 38075225Y | RESOLVE | Non-Hazardous | 46K50Y | $0 | $0 | Jul 30, 1998 |
| Jun 9, 1998 | 38075826J | RESOLVE | Non-Hazardous | 47O50O52B 52 B PROVIDE PROPER ELECTRIC CONNECTION 47-0-CLEAN GOVERNOR. | $180 | $0 | Sep 24, 1998 |
| Jan 29, 1996 | 38054013J | RESOLVE | Unknown | 75U. 75 5 YRS TEST PERFORM + FILE. | $0 | $0 | Apr 11, 1996 |
| Aug 22, 1991 | 34060587Y | RESOLVE | Non-Hazardous | ALTERED BUILDING OCCUPIED WITHOUT A VALID CERTIFICATE OF OCCUPANCY ALTERATION NUMBER 1000083561. REMEDY: OBTAIN C OF ... | $285 | $0 | Dec 19, 1991 |
| Jun 7, 1991 | 34058414N | RESOLVE | Non-Hazardous | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY DEPATMENT RECORDS FROM: LEGAL TWO APARTMENTS TO: O... | $0 | $0 | Oct 10, 1991 |
| Jan 7, 1991 | 38005567K | RESOLVE | Non-Hazardous | 74H. (74) PROVIDE PROPER CLEARANCE BETWEEN THE CWT AND THE BUFFER | $75 | $0 | May 2, 1991 |