ECB violations
24-26 East 13 Street, Manhattan • Block 00570 • Lot 0017
15 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Aug 3, 2026 | 39198835H | ACTIVE | CLASS - 1 | ATOI APPROX. 9AM, OBSERVED FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING THROUGHOUT CONSTRUCTION SITE: 1ST -3RD FLOOR. OB... | $2,500 | $2,500 | Oct 8, 2026 |
| Aug 3, 2026 | 39198836J | ACTIVE | CLASS - 1 | ATOI APPROX. 9:05AM OBSERVED FAILURE TO SAFEGUARD PROPERLY. EXPOSED FLOORING AT MEZZANINE LEVEL TO LOWER FLOOR, WHERE... | $10,000 | $10,000 | Oct 8, 2026 |
| Aug 3, 2026 | 39198834X | ACTIVE | CLASS - 2 | ATOI OBSERVED CONSTRUCTION WORK BEING PERFORMED( 1ST THROUGH 3RD FL) AT APPROX. 9:30AM FAILURE TO POST TPP NOTICES TH... | $1,250 | $1,250 | Oct 8, 2026 |
| Sep 25, 2025 | 35693335Y | ACTIVE | CLASS - 2 | NO CERTIFICATE OF CORRECTION ON FILE FOR VIOLATION #39062140Z ISSUED ON 5/13/22 FOR FAILURE TO MAINTAIN BUILDING IN A... | $1,250 | $0 | Dec 11, 2025 |
| Jan 13, 2025 | 39535918H | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN SIDEWALK DECK AS PER CODE REQUIREMENTS 3307.6.5.5 MATERIALS STORED ON DECK, AND 3307.6.5.6 FOUND ... | $2,400 | $2,400 | Mar 20, 2025 |
| May 13, 2022 | 39062140Z | ACTIVE | CLASS - 1 | AT TIME OF INSPECTION OBSERVED 2-TERRA-COTTA PEDESTALS MISSING ON 5TH FLOOR ORNAMENTAL BALCONY RAILING AND FELL ON TO... | $25,000 | $25,000 | Jun 30, 2022 |
| Feb 26, 2014 | 35038753X | RESOLVE | CLASS - 2 | ELECTRICAL WORK W/O A PERMIT. BSMT SERVICE EQUIPMENT: 600 AMP SERVICE SWITCH SQUARE D, 1 SET OF 500MCM SERVICE ENTRAN... | $400 | $0 | Apr 24, 2014 |
| Feb 26, 2014 | 35038755J | RESOLVE | CLASS - 2 | UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT,APPARATUS,MATERIALS,DEVICES,APPLIANCES OR WIRING IN USE.BSMT ELECTR... | $400 | $0 | Apr 24, 2014 |
| Feb 26, 2014 | 35038757N | RESOLVE | CLASS - 1 | 230.79,RATING OF SERVICE DISCONNECTING MEANS.THE SERVICE DISCONNECTINGMEANS SHALL HAVE A RATING NOT LESS THAN THE CAL... | $800 | $0 | Jul 3, 2014 |
| Feb 26, 2014 | 35038756L | RESOLVE | CLASS - 1 | 240.12,ELECTRICAL SYSTEM COORDINATION.WHERE AN ORDERLY SHUTDOWN IS REQUIRED TO MINIMIZE THE HAZARD TO PERSONNEL&EQUIP... | $0 | $0 | Jul 3, 2014 |
| Feb 26, 2014 | 35038754H | RESOLVE | CLASS - 1 | SIZE OF ALTERNATING - CURRENT GROUNDING ELECTRODE CONDUCTOR. THE SIZE OF THE GROUNDING ELECTRODE CONDUCTOR AT THE SER... | $400 | $0 | Apr 24, 2014 |
| Sep 6, 2006 | 32051301M | RESOLVE | Non-Hazardous | B4A,30A,16,50,A,B,C,32A,42,45A/B,36. 50-LOCK ON REAR DOOR OF MOBILE BOILER MISSING. 50A-SAIL SWITCH ON FRESH AIR FAN ... | $180 | $0 | Jan 10, 2007 |
| Feb 28, 1996 | 34133259J | RESOLVE | Non-Hazardous | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OF O:#74804.TEMP.EXPIRE 11-1-74.MEZZANINE LEVEL AT 2ND FLOOR CHANGE FROM ... | $800 | $0 | Jun 27, 1996 |
| May 18, 1992 | 34073329Y | RESOLVE | Non-Hazardous | FAILURE TO SAFETY AND PROPERLY REMOVE MATERIAL AND DEBRIS FROM CONSTRUTION SITE. DEBRIS AND LEFT OVER MATERIAL IN EAS... | $345 | $0 | Jul 16, 1992 |
| May 18, 1992 | 34073328M | RESOLVE | Non-Hazardous | FAILURE MAINTAIN DEFECTIVE VENT STACK AT THE EAST SIDE OF BUILDING JOINT OF ANGLE AT ABOUT 1ST STORY OF BUILDING IS L... | $230 | $0 | Jul 16, 1992 |