157-161 Varick Street, Manhattan
Manhattan • Block 00580 • Lot 0022 • Zip: 10013
Condition
What the city currently has open against this building, counted from its own records.
Address
Land use and zoning
Building
Latest assessment
Neighborhood
The area this lot falls inside, and the commute Hoodkit measures from it.
Getting around
Estimated 3 days ago- Fulton Street 15 min 5 walking, 10 riding
- Penn Station 16 min 5 walking, 11 riding
- Times Square 17 min 5 walking, 12 riding
- Union Square 20 min 5 walking, 15 riding
- Downtown Brooklyn 20 min 5 walking, 15 riding
- Grand Central 25 min 5 walking, 20 riding
Around this address
Transit and places within 0.5 miles of the lot.
Getting out
Subway
Railroad
Ferry
Bus
Citi Bike
Places nearby
Dean's
No description yet
Capitaine
No description yet
Somssi
No description yet
Cove
No description yet
Salt Hank’s
No description yet
King
No description yet
Hamburger America
No description yet
Bubby's
No description yet
Activity
Sales, filings, permits and violations from every dataset, in one order.
2024
2023
2022
-
Alteration Type I
FILING ALTERATION TYPE 1 FOR THE CHANGE OF USE FROM FACTORY TO STORAGE USE ON FLOORS AND RELATED CONSTRUCTION AS SHOW...
-
Alteration Type II
OBTAIN DUPLICATE COPY OF EQUIPMENT USE P ERMIT FO EXISTING MECHNCL HAVC UNIT ON ROOF NO WORK NO CHNG.OF USE OR OCCUPANCY
-
Alteration Type II
INSTALLING NEW HVAC AS PER PLAN. NO CHANGE IN EGRESS, USE OR OCCUPANCY.
-
CLASS - 2
EQUIPMENT INSTALLED CONTRARY TO APPROVED CD/5, C-HOOK USE IN CONJUNCTION WITH OUTRIGGER BEAM DOES NOT REFLECT ON APPR...
-
CLASS - 2
C-HOOK SUSPENDED SCAFFOLD INSTALLED CONTRARY TO DESIGN DRAWING TIEBACK ANCHOR PLATE INSTALLED CONTRARY TO THE DESIGN ...
2021
-
DOB violation May 10, 2021
E-ELEVATOR ELEVATORREQUIRED
-
Alteration Type III
INSTALLATION OF TEMPORARY ROOF PROTECTION AS PER PLANS. WORK SHALL COMPLY WITH 2014 BUILDING CODE CHAPTER 33. NO CHAN...
2020
-
DOB violation Apr 18, 2020
E-ELEVATOR ELEVATORREQUIRED
-
DOB violation Apr 18, 2020
E-ELEVATOR ELEVATORREQUIRED
-
DOB violation Apr 18, 2020
E-ELEVATOR ELEVATORREQUIRED
-
DOB violation Apr 18, 2020
E-ELEVATOR ELEVATORREQUIRED
2018
-
Alteration Type III
CONSTRUCTION OF SIGN STRUCTURE. SIGN APPLICATION FILED UNDER SEPARATE APPLICATION
-
Alteration Type III
PROPOSED INSTALLATION OF HEAVYDUTY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
-
CLASS - 2
67X10,02B10 REPAIR EMERGENCY PHONE; 02B10 ALARM BELL SOUND NOT LOUD ENOUGH.
2017
-
DOB violation May 8, 2017
E-ELEVATOR ELEVATORREQUIRED
2015
-
CLASS - 1
56Y10,45O02,56E410,98BB05. EXCESSIVE OIL LEAK, DIRT, ROCKS IN JAWS OF GOVERNOR, EXCESSIVE GRINDING NOISE FROM MACHINE...
2014
-
CLASS - 2
3307.6.4 FAILURE TO HAVE UPRIGHT MEMBERS OF SIDEWALK SHED PLUMB.NOTED:AT TIME OF INSPECTION 2 CORNER VERTICAL POSTS O...
The most recent 6 events from each dataset, so no one source takes the axis. Each tab holds the full record.
Property Contacts
Contact information aggregated from multiple government sources
Building Permits
Owner information from Department of Buildings filings
Recent Building Permits
Owner information from recent DOB NOW filings
Deed Records
Parties from ACRIS deed and mortgage records
Property Records
Owner information from assessment and PLUTO records