Skip to content

ECB violations

7 Avenue South, Manhattan • Block 00582 • Lot 0041

23 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Aug 12, 2025 39156868Z RESOLVE CLASS - 2 FAILURE TO SUBMIT CERTIFICATE OF CORRECTION FOR VIOLATION # 39130021H ISSUED ON 11/11/2024 FOR FAILURE TO MAINTAIN BU... $625 $0 Nov 20, 2025
Aug 12, 2025 39156869K RESOLVE CLASS - 2 FAILURE TO SUBMIT CERTIFICATE OF CORRECTION FOR VIOLATION # 39130022J ISSUED ON 11/11/2024 FOR FAILURE TO PROVIDE UNO... $625 $0 Nov 20, 2025
Nov 12, 2024 39130023L ACTIVE CLASS - 2 WORK WITHOUT A PERMIT. AT TIME OF INSPECTION, OBSERVED A 1-STORY WOOD-FRAMED ROOF STRUCTURE, APPROXIMATELY 8' D X 8' ... $1,250 $1,250 Apr 30, 2026
Nov 12, 2024 39130022J RESOLVE CLASS - 1 FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. AT TIME OF INSPECTION, OBSERVED STRUCTURE BLOCKING SECONDARY MEANS O... $1,280 $0 Nov 6, 2026
Nov 12, 2024 39130021H RESOLVE CLASS - 1 FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. AT TIME OF INSPECTION, OBSERVED COMBUSTIBLE WOOD STRUCTURE A... $1,250 $1,250 Apr 30, 2026
Jul 6, 2021 39043940N ACTIVE CLASS - 2 NO CLEANOUT DOOR AT BASE OF CHIMNEY/PIPE LEAKING ABOVE BOILER ROOM DOOR/OUTSIDE INLET TO BOILER ROOM FRESH AIR DUCT I... $3,125 $0 Aug 26, 2021
Jul 6, 2021 39043939X ACTIVE CLASS - 2 ILLEGAL DRAFT INDUCER INSTALLED ON BOILER/ENGINEERS CHIMNEY AFFIDAVIT REQUIRED VERIFYING CAPABILITY + INTEGRITY OF CH... $3,125 $0 Aug 26, 2021
Aug 17, 2020 39027105J RESOLVE CLASS - 2 AT TIME OF INSPECTION OBSERVED 5-WINDOW A/C UNITS FROM 2ND TO 5TH FLOOR LEVEL ERECTED OVER THE PEDESTRIANS SIDEWALK W... $0 $0 Oct 1, 2020
Jun 12, 2013 35021308R ACTIVE CLASS - 1 ELECTRICAL WORK W/O A PERMIT. GROUND FLR BAR RESTAURANT DENNCHY'S NO APP ON FILE FOR ELECTRICL SIGN "STELLA" ARTOIS. ... $1,600 $0 Aug 29, 2013
Aug 9, 2008 34699051N RESOLVE CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. DEFECTS NOTED: FIREESCAPE STAIR ALONG 7TH AVE SOUTH HAS STEPS MISS... $1,000 $0 Apr 2, 2009
Jun 6, 2008 34646814N RESOLVE Non-Hazardous OAC W/OUTDOOR AD SIGN ATTACHED TO REAR 3RD FLOOR FIRE ESCAPE. SIGN COPY, "GMAC REAL ESTATE". REMEDY: REMOVE ILLEGAL S... $0 -$5,000 Aug 29, 2008
Jun 6, 2008 34646815P RESOLVE Non-Hazardous FAILURE TO MAINTAIN BLDG.DEFECT NOTED.REAR IRON FIRE ESCAPE BETWEEN THIRD & FOURTH FLOORS IS MISSING A STAIR TREAD AT... $800 $0 May 14, 2009
Jun 6, 2008 34646812J RESOLVE Non-Hazardous SEC. 26-262AC. PROPERTY OWNER ACTING AS AN OAC FAILURE TO OBTAIN VALIDOAC REGISTRATION NUMBER WHILE ENGAGING IN OUTDO... $0 $0 Aug 28, 2008
Jun 6, 2008 34646811H RESOLVE Non-Hazardous OAC FAILURE TO OBTAIN PERMIT FOR OUTDOOR AD SIGN. SIGN COPY, "GMAC REAL ESTATE". REMEDY: REMOVE ILLEGAL SIGN & STRUCT... $0 $0 Aug 29, 2008
Jun 6, 2008 34646813L RESOLVE Non-Hazardous SEC. AC 26-262. OAC W/OUTDOOR AD SIGN PROHIBITED IN A C2-6 ZONING DISTRICT. SIGN COPY, "GMAC REAL ESTATE". REMEDY: RE... $0 $0 Aug 29, 2008
Jun 5, 2008 34650240P RESOLVE Non-Hazardous FAILURE TO MAINTAIN BLDG NOTED AT REAR FIRE ESCAPE BETWEEN 2ND AND 4TH FLRS STEPS MISSING OR BROKEN AWAY FROM FIRE ES... $350 $0 Jul 19, 2012
Jan 12, 2005 34455816P RESOLVE Non-Hazardous FAILURE TO PROPERTY TERMINATE EXHAUST. NOTED:AT 1 FLOOR REAR EXHAUST IMPROPERLY TERMINATES APPROX 4'-0' BELOW 2 FLOOR... $400 $0 Mar 31, 2005
Feb 27, 2002 34316182M RESOLVE Non-Hazardous WORK WITHOUT A PERMIT. NOTED: EXCAVATION OF BASEMENT (APPROX 30X25X2' DEEP) IS IN PROGRESS WITHOUT FIRST OBTAINING A ... $500 $0 Feb 27, 2003
Mar 28, 2001 34274623X RESOLVE Hazardous FAILURE TO MAINTAIN BLDG(EXTERIOR)NOTED:BROMNSTONE FACADE CRACKED 2 SPALLING,LOOSE.DEFECTS AT 2ND THRU 5TH FLOOR IN V... $800 $0 Jun 28, 2001
Aug 9, 1999 34222755N RESOLVE Hazardous FAILURE TO MAINTAIN EXTERIOR BUILDING WALL. NOTED: BROWNSTONE FACADE CRACKED & SPALLING & LOOSE. AT 2ND FLOOR THRU 5T... $800 $0 Jul 13, 2000
Dec 15, 1997 34168456Z RESOLVE Non-Hazardous WORK DOES NOT CONFORM TO APPROVED PLAN # 101842874. NOTED: ALTERATION AT TOP FLOOR AND ROOF CONTRARY TO APPROVED PLAN... $0 $0 Apr 30, 1998
Sep 25, 1997 34164932M RESOLVE Hazardous FAILURE TO MAINTAIN EXTERIOR BLDG WALL. NOTED: FRONT FACADE OF BLDG BROWNSTONE SPALLING THROUGH 2-5 FLOORS. STONEWORK... $5,000 $0 Apr 30, 1998
Sep 4, 1996 34138532Y RESOLVE Hazardous WORK WITHOUT A PERMIT WORK NOTED REMOVING BROWN STONE PEICES FROM ENTIRE FRONT WALL SOUTH WITHOUT FIRST ERECTING PROT... $800 $0 Nov 14, 1996