ECB violations

51 Leroy Street, Manhattan • Block 00583 • Lot 0040

42 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Oct 27, 2025 39164894M ACTIVE CLASS - 1 FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. AT TIME OF INSPECTION PASSAGE WAY IS STILL OBSTRUCTED ., REMOVE OBST... $12,500 $12,500 Dec 21, 2026
Oct 27, 2025 39164889H ACTIVE CLASS - 1 UNLAWFUL ACTS. FAILURE TO COMPLY WITH COMMISSIONER'S ORDER. NO PERMIT ON FILE AS OF 10/27/25.FOR VIO#39127859Y., COMP... $12,500 $12,500 Jan 8, 2026
Oct 27, 2025 39164882P ACTIVE CLASS - 1 UNLAWFUL ACTS. FAILURE TO COMPLY WITH COMMISSIONER'S ORDER. .NO PERMIT AS OF 10/27/25.FOR VIO#39116673M., COMPLY WITH... $12,500 $12,500 Dec 21, 2026
Oct 18, 2024 39127860L ACTIVE CLASS - 2 I OBSERVED NEW PARTITION WALLS CONSTRUCTED IN APT 1C, 1ST FL, OUTSIDE WALL HALLWAY, REMOVAL OF EXISTING WALLS, INTERI... $6,250 $6,250 Dec 26, 2024
Oct 18, 2024 39127861N ACTIVE CLASS - 1 I OBSERVED OBSTRUCTION OF EXIT/EGRESS PASSAGEWAY FROM FIRE ESCAPE AT REAR SIDE OF BLDG. EXP. 03, WOOD STOCKAGE FENCE ... $6,250 $6,250 Dec 26, 2024
Oct 18, 2024 39127862P ACTIVE CLASS - 2 I OBSERVED NEW PLUMBING WORK INSTALLED IN APT 1C, 1ST FL, FOR KITCHEN AREA & BATHROOM, B= INCH COPPER PIPE FOR WATER,... $6,250 $6,250 Dec 26, 2024
Oct 18, 2024 39127859Y ACTIVE CLASS - 1 I OBSERVED NEW ELECTRIC WORK INSTALLED IN APT 1C, 1ST FL, 18- OUTLETS W/ WIRING, ON CEILINGS & WALLS, NEW ELECTRIC-PA... $12,500 $12,500 Dec 26, 2024
Apr 18, 2024 39116673M ACTIVE CLASS - 1 AT TIME OF INSPECTION OBSERVED DOOR AT REAR OF 53 LEROY STREET EXPOSURE #3 WHERE A WINDOW IS SUPPOSED TO BE. THIS WOR... $12,500 $12,500 Aug 22, 2024
Jan 28, 2022 39055053P RESOLVE CLASS - 2 MISSING KNOB ON DOOR TO BOILER ROOM ,HAS HOLE,CANNOT HAVE OPEN VENTS FROM OTHER ROOMS TO BOILER ROOM,MISSING COVERS O... $0 $0 Jul 14, 2022
Nov 13, 2018 35372557M ACTIVE CLASS - 2 WORK WITHOUT A PERMIT.NOTED:AT CELLAR RECREATION ROOM,ERECTED FULL HEIGHT PARTITIONS WITH PLUMBING AND ELECTRICAL CRE... $1,250 $1,250 Feb 21, 2019
Nov 13, 2018 35372558Y RESOLVE CLASS - 2 OCCUPANCY CONTRARY TO CERTIFICATE OF OCCUPANCY OR DEPT OF BUILDING RECORDS AT TIME OF INSPECTION OBSERVED AT CELLAR 1... $0 $0 Feb 21, 2019
Mar 22, 2018 35313081X RESOLVE CLASS - 1 UNLAWFUL ACTS. FAILURE TO COMPLY W/AN ORDER OF THE COMMISSIONER. IN 3-22-17 A ELECTRICAL VIOLATION WAS ISSUE TO THE R... $6,250 $6,250 Aug 2, 2018
Jan 25, 2018 35312713K RESOLVE CLASS - 1 UNLAWFUL ACTS. FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER. IN SEPTEMBER 01,2017. A ELECTRICAL VIOLATION WAS ... $2,400 $2,400 Aug 2, 2018
Nov 22, 2017 35295677K RESOLVE CLASS - 2 PEDESTRIAN PROTECTION NOT TO CODE SPECIFICATION.NOTE:AT TIME OF INSPECTION I OBSERVED SIDEWALK SHED WITH FOLLOWING OB... $2,400 $0 Jul 26, 2018
Nov 22, 2017 35295678M RESOLVE CLASS - 1 SUPPORTED SCAFFOLD NOT TO CODE SPECIFICATION.NOTE: AT TIME OF INSPECTION I OBSERVED SUPPORTED SCAFFOLD WITH UNSECURED... $800 $352 Jul 26, 2018
Sep 1, 2017 35284892J RESOLVE CLASS - 1 UNLAWFUL ACTS.FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER.IN MARCH 22,2017.THREE ELECTRICAL VIOLATION WAS ISS... $2,400 $0 Feb 22, 2018
Jul 5, 2017 35271662L RESOLVE CLASS - 1 EC250.4/NON-CURRENT CARRYING ELECTRICAL CONDUCTIVE MATERIAL IS NOT GROUNDED SIDEWALK SHED IS METAL;COULD BE ENERGIZED... $1,600 $0 Apr 5, 2018
Jul 5, 2017 35275725H RESOLVE CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION#35228444J ISSUED ON 03/22/17 AND TO FIL... $800 $0 Apr 5, 2018
Jul 5, 2017 35275726J RESOLVE CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION#35228445L ISSUED ON 03/22/17 AND TO FIL... $800 $0 Apr 5, 2018
Apr 11, 2017 35124340Z ACTIVE CLASS - 1 WORK WITHOUT A PERMIT "CONSTRUCTION" NOTED:AT ROOF LEVEL,THREE 3) WOODEN DECKS HAVE BEEN CONSTRUCTED TWO @APPROX 8'X2... $800 $0 Nov 30, 2017
Apr 11, 2017 35124339L RESOLVE CLASS - 1 3301.10 OBSCURRED LANDFUL SIGNS.NOTED:AT TIME OF INSPECTION OBSERVED LAWFUL SIGNS BEING OBSTRUCTED BY THE INSTALLATIO... $1,600 $0 Oct 19, 2017
Apr 11, 2017 35124338J RESOLVE CLASS - 1 1510 EGRESS FROM FIRE ESCAPE-BALCONIES NOT TO BE OBSTRUCTED.NOTED: AT TIME OF INSPECTION OBSERVED ON EXP #1 FIRE ESCA... $1,600 $0 Oct 19, 2017
Mar 22, 2017 35228446N RESOLVE CLASS - 2 FAILURE TO SUPPORT SECURE RACEWAYS CABLE ASSEMBLIES BOXES CABINETS FITTINGS.FIXTURES AND RACEWAYS NOT SUPPORTED THROU... $800 $0 Nov 9, 2017
Mar 22, 2017 35228440M RESOLVE CLASS - 1 SEC. 250.4 NON CURRENT CARRYING ELECTRICAL CONDUCTIVE MATERIAL IS NOT GROUNDED. SIDEWALK SHED IS METAL & COULD BE ENE... $0 $0 Dec 14, 2017
Mar 22, 2017 35228441Y RESOLVE CLASS - 2 FAILURE TO INSTALL GROUND FAULT CIRCUIT INTERRUPTER GFCI PROTECTION AS REQUIRED. NO GFCI INSTALLED IN SIDEWALK SHED. ... $0 $0 Dec 14, 2017
Mar 22, 2017 35228442X RESOLVE CLASS - 2 FAIL TO PROVIDE EFFECTIVE ELECTRICAL CONTINUITY FOR METAL RACEWAYS ENCLOSURESMCABLE,ARMOR. LIGHTING RACEWAY TO SIDEWA... $0 $0 Dec 14, 2017
Mar 22, 2017 35228443H RESOLVE CLASS - 2 FAILURE TO SECURE SUPPORT RACEWAYS CABLE ASSEMBLIES BOXES CABINETS & FITTINGS. FIXTURE BOXES & RACEWAYS IN SIDEWALK S... $0 $0 Dec 14, 2017
Mar 22, 2017 35228444J RESOLVE CLASS - 1 UNSAFE,UNAPPROVED,UNSUITABLE ELECTRICAL EQUIPMENT DEVICES MATERIALS APPARATUS MATERIALS APPLIANCES OR WIRING IN USE D... $1,600 $0 Nov 9, 2017
Mar 22, 2017 35228445L RESOLVE CLASS - 1 FAILURE TO GROUND ELECTRICAL SYSTEM.NO GROUND CONDUCTOR PROVIDED TO 400 AMP SERVICE SWITCH IN BASEMENT.REM:PROVIDE GR... $4,800 $0 Nov 9, 2017
Mar 22, 2017 35228447P RESOLVE CLASS - 2 OBSERVED AT 11:30 AM HALLWAYS FIXTURES AND ENERGENCY LIGHTS INSTALLED THROUGHOUT HALLWAY.NO APPLICATION ON FILE FOR E... $800 $0 Nov 9, 2017
Mar 22, 2017 35274437Z RESOLVE CLASS - 2 FAILURE TO INSTALL GROUND FAULT CIRCUIT INTERRUPTER GFCI PROTECTION AS REQUIRED. NO GFCI INSTALLED IN SIDEWALK SHED. ... $5,000 $5,000 Jul 12, 2018
Mar 22, 2017 35274436R RESOLVE CLASS - 1 EC250.4 NON CURRENT CARRYING ELECTRICAL CONDUCTIVE MATERIAL IS NOT GROUNDED. SIDEWALK SHED IS METAL AND COULD BE ENER... $4,000 $4,000 Jul 12, 2018
Mar 22, 2017 35274438K RESOLVE CLASS - 2 FAILED TO PROVIDE EFFECTIVE ELECTRICAL CONTINUITY FOR METAL RACEWAYS ENCLOSURES CABLE ARMOR. LIGHTING RACEWAY TO SIDE... $3,000 $3,000 Jul 12, 2018
Mar 22, 2017 35274439M RESOLVE CLASS - 2 FAILURE TO SECURE SUPPORT RACEWAYS CABLE ASSEMBLIES BOXES, CABINETS AND FITTINGS FIXTURE BOXES AND RACEWAYS IN SIDEWA... $2,000 $2,000 Jul 12, 2018
Aug 25, 2012 34979615X RESOLVE CLASS - 1 OCCUPANCY CONTRARY TO THAT ALLOWED BY BLDGS DEPARTMENT RECORDS. ILLEGAL OCCUPANCY NOTED:APT 2B CONVERTED FROM CLASS "... $2,400 $0 Jan 10, 2013
Aug 25, 2012 34979618L RESOLVE CLASS - 1 907.2.8:FAILURE TO PROVIDE FIRE ALARM. NOTED:APT 2B OCCUPIED AS A TRANSIENT USE WITHOUT PROVIDING FIRE ALARM. REM:DIS... $1,600 $0 Jan 10, 2013
Aug 25, 2012 34979617J RESOLVE CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODE COMPLAINT MANNER. FAILURE TO PROVIDE NUMBER OF REQUIRED MANY OF EGRESS PER EVERY FLR... $1,200 $0 Jan 10, 2013
Aug 25, 2012 34979616H RESOLVE CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. LACK OF A SYSTEM OFAUTOMATIC SPRINKLER WHERE REQUIRED PER BC 903.2... $1,000 $0 Jan 10, 2013
Aug 31, 2004 34443538X RESOLVE Hazardous FAILURE TO MAINTAIN BLDG (EXTERIOR)NOTED:SMOKE STACK PRESENT AT REAR OF BLDG (LENGTH OF BLDG)HAS DEFECTIVE SECTION LO... $0 $0 Dec 2, 2004
Apr 12, 2004 34432660X RESOLVE Non-Hazardous WORK DOES NOT CONFORM TO APPROVED PLANS. NON CONFORMING WORK NOTED: TIE RODS NOT CONNECTED TO FLOOR JOIST SYSTEM (INS... $0 $0 May 27, 2004
Mar 11, 2004 34432376Z RESOLVE Hazardous FAILURE TO SAFEGUARD PUBLIC & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS NOTED : WHILE CONSTRUCTION OPERATIONS UNDE... $0 $0 May 13, 2004
Feb 26, 1996 34133256Y RESOLVE Non-Hazardous WORK WITHOUT A PERMIT WORK NOTED ALTER 3 APT AT 1ST FLOOR OF 51-53 LEROY STREET CEATING DUPLEX TO CELLAR 1B-1C-1D.REM... $0 $0 Apr 18, 1996