ECB violations
16 Barrow Street, Manhattan • Block 00591 • Lot 0033
31 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Mar 25, 2025 | 39142696Y | RESOLVE | CLASS - 2 | WORK WITHOUT A PERMIT. AT TIME OF INSPECTION, NOTED FABRIC EXTERIOR STRUCTURE APPROXIMATELY 6'D X 28' L ATTACHED TO T... | $125 | $0 | Jul 10, 2025 |
| Dec 27, 2022 | 39510853P | RESOLVE | CLASS - 1 | NOTE AT TIME OF INSPECTION I OBSERVED CONSTRUCTION OPERATION THROUGHOUT BUILDING WITH NO PERMIT. STOP ALL CONSTRUCTIO... | $1,250 | $0 | Jul 13, 2023 |
| Dec 27, 2022 | 39510851L | RESOLVE | CLASS - 1 | AT TIME OF INSPECTION I OBSERVED ALTERATION JOB THROUGH OUT THE BUILDING WITH THREE OCCUPIED APARTMENTS AND NO TENANT... | $2,500 | $0 | Jul 13, 2023 |
| Jun 24, 2019 | 35423795P | RESOLVE | CLASS - 1 | AN UNLAWFUL ACT. FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER. FAILURE TO CORRECT AND CERTIFY SUMMONS #3535890... | $2,500 | $0 | Oct 10, 2019 |
| May 10, 2019 | 35358905Z | RESOLVE | CLASS - 1 | UNAPPROVED UNSAFE UNSUITABLE ELECTRICAL EQUIPMENT, APPARATUS MAERIALS DEVICES APPLIACNES OR WIRING IN USE. OBSERVED I... | $400 | $0 | Sep 19, 2019 |
| Nov 23, 2013 | 35013981R | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.EXHAUSE DISCHARGE MUST BE NO CLOSE THAN 10'FROM BLDG OPENING AS... | $4,000 | $0 | Jan 16, 2014 |
| Nov 23, 2013 | 35013980P | RESOLVE | CLASS - 2 | WORK W/O A PERMIT.WORK NOTED:AT NORTH EAST SIDE ALLEYWAY OF PREMISES HAVING ERECTED WALL MOUNTED EXHAUST CONNECTED TO... | $4,000 | $0 | Jan 16, 2014 |
| May 18, 2012 | 34896493N | RESOLVE | CLASS - 1 | WORK W/O A PERMIT. UPON PHYSICAL INSPECTION FOUND PARTS OF SANITARY LINES BEING ALTERED/REPAIRED/REPLACED W/O A PERMI... | $8,000 | $0 | Jul 12, 2012 |
| May 18, 2012 | 34896494P | RESOLVE | CLASS - 1 | SEC. FGC-404.1. UPON PHYSICAL INSPECTION FOUND GAS PIPING IN PUBLIC STAIR ENCLOSURES ON 1,2 FLRS - CONTRARY TO FUEL G... | $8,000 | $0 | Jul 12, 2012 |
| Oct 22, 2009 | 34810236M | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLAINT MANNER. NOTED: CRACKS IN THE FLR OF STAIRWELL HALLWAY AT 3RD FLR. ALSO... | $2,500 | $0 | Dec 17, 2009 |
| Oct 4, 2006 | 32051311X | RESOLVE | Non-Hazardous | B4A,36,50,50A,50B,50C.50-OIL LINES UNPROTECTED, IN CONTACT W/ FLUE ANDANTI SYPHON VALUE MISSING.50A-OIL LEAK AT OIL F... | $350 | $0 | May 24, 2007 |
| Mar 8, 2006 | 34490375M | RESOLVE | Non-Hazardous | PLUMBING WORK W/O A PERMIT. USE OR INSTALLATION OF PLUMBING MATERIALS OR EQUIPMENT WHICH DO NOT COMPLY WITH RS-16. OB... | $900 | $0 | Jun 15, 2006 |
| Feb 15, 2006 | 32049552Y | RESOLVE | Hazardous | CEASE USE B4B/50A 51/50B 3B/50C 36/50D 45A/50E 50/50F 50) BOILER NOT INTERLOCKED WITH PROVING SWITCH WITH FRESH AIR F... | $1,250 | $0 | Apr 6, 2006 |
| Feb 15, 2006 | 32049551M | RESOLVE | Hazardous | CEASE USE B4B 51 3B 50 50A 50B 50) GAS FLUE INTO OIL FLUE IN BOILER ROOM. 50A) BOILER NOT INTERLOCKED WITH PROVIDING ... | $2,500 | $0 | Apr 6, 2006 |
| Jan 25, 2006 | 34505715Z | RESOLVE | Non-Hazardous | WORK W/O PERMITS. WORK NOTED: AT APT. # 14 HAVING (1) REMOVED FULL HEIGHT PARTITIONS. (2) DECREASING CEILING HEIGHT B... | $2,500 | $0 | Mar 16, 2006 |
| Feb 20, 2004 | 34417271R | RESOLVE | Non-Hazardous | OCCUPANCY CONTRARY TO THAT ALLOWED BY C/O NOTED:C/O #48464 STATES LEGAL OCCUP SIDEY OF 1SY FLOOR ARE FOUR (4) APTS"SU... | $0 | $0 | Aug 19, 2004 |
| Nov 21, 2003 | 32043535P | RESOLVE | Non-Hazardous | BQ9 36 38 50 50A 50B 50C 50D 50E 21C BQ9 WELL MCLAIN SESIES 80 38 FAN IN BASEMENT BOILER ROOM IS AN EXHAUST EAN VALVE... | $880 | $0 | Jun 17, 2004 |
| Jan 24, 2003 | 32041179Z | RESOLVE | Non-Hazardous | B4A-24A. 24A - REMOTE CONTROL SWITCH IS NOT ISOLATED FOR BOILER ONLY. LIGHTS - FAN AND BOILER IS OPERATED BY SWITCH. | $10,000 | $0 | May 29, 2003 |
| Jan 24, 2003 | 32041177P | RESOLVE | Non-Hazardous | B4A-21C-50A-50B-50C-50D-50E. 50A - PRESSURE CONTROLS NOT SEPARATED. 50B - NO SYPHON ON STEAM GUAGE. 50C - NO RATING P... | $10,000 | $0 | Jun 26, 2003 |
| Jan 24, 2003 | 32041178R | RESOLVE | Hazardous | B4B-4B-38-16-50. 50 - INTAKE FAN DOESN'T DRAW FRESH SIR FRON OUTSIDE AIR. BOILER ROOM - HAS EXCESSIVE HEAT WHEN BOILE... | $2,500 | $0 | Jun 26, 2003 |
| Dec 9, 2002 | 34372657N | RESOLVE | Non-Hazardous | OCCUPANCY CONTRARY TO THAT ALLOWED BY COF O NOTED ON 1ST STORY, CALSS A APARTMENT SPACE CONVERTED HAS BEEN / IS BEING... | $0 | $0 | Jun 26, 2003 |
| Dec 3, 2002 | 34333466Z | RESOLVE | Hazardous | FAILURE TO PROVIDE TWO MEANS OF EGRESS FROM ROOM OR SPACE WHERE REQUIRED. NOTED: AT FIRST FL APT NORTH WEST CORNER OF... | $2,500 | $0 | Jan 23, 2003 |
| Nov 26, 2002 | 32040900K | RESOLVE | Non-Hazardous | B4A-21C-32A-32B-50A-50B-50C-50D-50E-50F. 21C OIL LINES NOT SECURED. 50A NO DISCHARGE PIPE ON SAFETY VALVE. 50B PRESSU... | $2,500 | $0 | Jan 16, 2003 |
| Nov 25, 2002 | 32040774Z | RESOLVE | Hazardous | B4B-1-24A-51. 24A - REMOTE CONTROL SWITCH IS NOT ISOLATED TO BOILER ONLY. LIGHTS, FAN AND BOILER ALL CONNECTED TO SWI... | $2,500 | $0 | Jan 9, 2003 |
| Oct 31, 2002 | 34372481Z | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN: EXTERIOR BUILDING WALL: NOTED; ON WESTERLY FACDE (FARMING 7 AVE SOUTH) THERE IS MORTAR MISSING F... | $180 | $0 | Apr 3, 2003 |
| Oct 31, 2002 | 34372480R | RESOLVE | Non-Hazardous | WORK WITHOUT PERMIT: NOTED A METALCHIMNEY APPROX 2 IN DIAMETER RUNNING FROM 1ST STORY TO ROOF WITH ROFF LEVEL EXHAUST... | $500 | $0 | Apr 3, 2003 |
| Oct 23, 2002 | 32040752H | RESOLVE | Non-Hazardous | B4B/3A/3B/32A/40/48/50A/50B/50C/50D/50E/50F/50G/50H/50I/51. B4B HAZARDOUS CONDITON (3A03B) FLUE PIPE TO BE REPLACED 3... | $800 | $0 | Apr 3, 2003 |
| Jan 22, 2001 | 34263006R | RESOLVE | Hazardous | FAILURE TO MAINTAIN EXTERIOR BLDG WALL MISSING AND DEFECTIVE MASONARY,COPING AND LINTELS AT VARIOUS LOCATION,AND AT A... | $2,500 | $0 | Mar 8, 2001 |
| May 23, 2000 | 34238077J | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT. (50% OF WORK COMPLETED) NOTED: DEMOLITION IN 1ST FLOOR, 1ST FLOOR 1STF2 ROOF + CELLARS INCL. R... | $0 | $0 | Jul 13, 2000 |
| May 23, 2000 | 34238078L | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN BLDG NOTED;VERTICAL AND HORIZONTAL CRACKS IN WALLS AND CEILING OF 1ST FT APT, 1/8" WIDE. LOCATION... | $350 | $0 | Sep 14, 2000 |
| Dec 6, 1999 | 34227992J | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT. NOTED AT SECOND FLOOR LEVEL WOOD FRAME AND PLYWOOD SHED STRUCTURE FIXED TO EXTERIOR WALLS APPR... | $2,500 | $0 | Jan 20, 2000 |