ECB violations
511-525 West 36 Street, Manhattan • Block 00708 • Lot 0020
27 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Mar 11, 2026 | 39179994L | RESOLVE | CLASS - 2 | I OBSERVED IN ROOF TOP MECHANICAL ROOM, GAS REGULATORS ON MAIN HOUSE PIPE WERE NOT VENTED CORRECTLY ALLOWING GAS TO E... | $3,125 | $3,125 | May 21, 2026 |
| Nov 24, 2023 | 39100012Z | RESOLVE | CLASS - 2 | 1/X/10 EMERGENCY STOP SWITCH BELL DOES RING WHEN ACTIVATED INOPERATIVEREPAIR,98/M/7, 5 YEAR TAG MISSING PROVIDE, 59/X... | $0 | $0 | Feb 1, 2024 |
| Mar 1, 2019 | 35369440L | RESOLVE | CLASS - 1 | BC3310.8.2.1 SITE SAFETY MANAGER FAILED TO NOTIFY THE DEPT OF UNSAFE CONDITIONS/ACCIDENT. AT THE TIME OF INSPECTION O... | $1,250 | $0 | Sep 19, 2019 |
| Feb 25, 2019 | 35363737P | RESOLVE | CLASS - 1 | BC 3301.2 FAILURE TO INSTITUTE AND MAINTAIN SAFE OPERATIONS. NOTE:AT THE TIME OF MY INSPECTION OF AN ACTIVE JOBSITE,R... | $2,530 | $0 | Apr 18, 2019 |
| Nov 27, 2018 | 35377964M | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS.IN RESPONSE TO AN INCIDENT FOR THE ... | $10,000 | $0 | Feb 7, 2019 |
| Nov 27, 2018 | 35377963K | RESOLVE | CLASS - 1 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS.IN RESPONSE TO AN INCIDENT FOR TH... | $2,500 | $0 | Feb 7, 2019 |
| Jul 30, 2018 | 35343026K | RESOLVE | CLASS - 1 | 3304.7 REQUIRED MEANS OF EGRESS. AT TIME OF INSPECTION ON AN ACTIVE JOBSITE OF A 39 STORY BUILDING. OBSERVED THAT EGR... | $2,500 | $0 | Sep 13, 2018 |
| Jul 25, 2018 | 35345120X | RESOLVE | CLASS - 1 | HOUSEKEEPING. @ TIME OF INSP OF A 39 STORY NB OBSERVED CERTAIN AREAS ON FLOORS 30 THROUGH 39 W/ INADEQUATE HOUSEKEEPI... | $0 | $0 | Sep 13, 2018 |
| May 10, 2018 | 35331118J | RESOLVE | CLASS - 1 | BC3301.2.FAILURE TO HOLES COVERED.AT TIME OF INSPECTION OBSERVED ACTIVE JOB SITE.FAILURE TO MAINTAIN HOLES.COVERED WA... | $2,500 | $0 | Jun 28, 2018 |
| Feb 13, 2018 | 35301460H | RESOLVE | CLASS - 1 | BC 3301.1.2 FAILURE TO HAVE FDNY PERMIT FOR PROPANE STORED ON SITE. NOTICED AT TIME OF INSPECTION NB IN PROGRESS NOTI... | $1,600 | $0 | Apr 5, 2018 |
| Dec 4, 2017 | 35285599P | RESOLVE | CLASS - 2 | FAILURE TO SAFEGUARD ALL PESONS AND PROPERTY EFFECTED BY CONSTRUCTION OPERATIONS PARTIAL STOP WORK ON ALL BACKER SCAF... | $5,000 | $0 | Jan 18, 2018 |
| Dec 2, 2017 | 35300827K | RESOLVE | CLASS - 1 | SEC: BC 3301.6. NO DRAWINGS (FALL ARREST SYSTEM). @ TIME OF INSP OF A 39 STORY BLDG CURRENTLY ON ROOF LEVEL, OBSERVED... | $1,600 | $0 | Jan 19, 2018 |
| Oct 15, 2017 | 35225432Z | RESOLVE | CLASS - 1 | INADEQUATE SAFETY MEASURES WITH OPERATIONS OF CRANE/HOISTING EQUIPMENTIN UNSAFE MANNER.AT TIME OF INSPECTION I ASKED ... | $10,000 | $0 | Jan 25, 2018 |
| Oct 13, 2017 | 35225431R | RESOLVE | CLASS - 1 | INADEQUATE SAFETY MEASURES WITH OPERATIONS OF CRANE/HOISTING EQUIPMENTIN UNSAFE MANNER.AT TIME OF INSPECTION I REQUES... | $4,800 | $0 | Jan 25, 2018 |
| Jan 4, 2017 | 35217393P | RESOLVE | CLASS - 2 | JOB SITE FENCE NOT CONSTRUCTED TO CODE. NOTICED AT TIME OF INSPECTION JOB SITE FENCE ERECTED AT EXP#1 NOT TO CODE FEN... | $0 | $0 | Feb 23, 2017 |
| Jan 4, 2017 | 35217391L | RESOLVE | CLASS - 2 | SEC. 3304.8 DEWATERING SITE W/O DEP PERMIT TO DEWATER. NOTICED AT TIMEOF INSPECTION NB IN PROGRESS. NOTICED AT EXP#1 ... | $800 | $0 | Feb 23, 2017 |
| Jan 4, 2017 | 35217392N | RESOLVE | CLASS - 2 | SEC. 3307.2.1 DOT PERMIT NOT IN CONJUNCTION. NOTICED AT TIME OF INSPECTION NOTICED NB IN PROGRESS. NOTICED AT EXP#1 T... | $0 | $0 | Feb 23, 2017 |
| Apr 26, 2016 | 35174823Z | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE APPROVED/ACCEPTED PLANS AT THE JOBSITE. AT THE TIMEOF INSPECTION,THE RESPONDENT FAILED TO PROVIDE ... | $0 | $0 | Jun 16, 2016 |
| Apr 26, 2016 | 35174824K | RESOLVE | CLASS - 1 | FAILURE TO NOTIFY THE DOB W/I 24-48HRS OF THE START OF EXCAVATION. AT THE TIME OF INSPECTION,THE EXCAVATION WORK HAD ... | $1,200 | $0 | Jun 16, 2016 |
| Dec 28, 2013 | 35087328X | RESOLVE | CLASS - 2 | FAILURE TO POST DOT PERMIT FOR STREET CLOSING. A DEBRIS CONTAINER HAS BEEN PLACED IN STREET CLOSING CURB LANE OF W 36... | $250 | $0 | Mar 20, 2014 |
| Sep 29, 2013 | 35065242H | RESOLVE | CLASS - 2 | JOB SITE FENCE NOT CONSTRUCTED OR MAINTAINED PURSUANT TO SUBSECTION. DEFECTS NOTED: CONSTRUCTION SITE FENCE ERECTED U... | $0 | $0 | Nov 14, 2013 |
| Sep 26, 2013 | 35019345N | RESOLVE | CLASS - 1 | SEC. BC 3303.5.2. DROPPING OR THROWING PROHIBITED. AT THE TIME OF MY INSPECTION DEMO WORK IN PROGRESS APPROX 15 WORKE... | $1,600 | $0 | Nov 14, 2013 |
| Aug 16, 2013 | 35028953L | RESOLVE | CLASS - 1 | SEC. BC 3306.2. FAILURE TO PROTECT UTILITY LINES OF ADJOINING BLDG - UPON INSPECTION DEMOLITION WORK OF 5 STY BLDG CO... | $800 | $0 | Jan 23, 2014 |
| Feb 24, 2004 | 34401498P | RESOLVE | Hazardous | WORK WITHOUT A PERMIT HAZARDOUS WORK NOTED AT ROOF AN ADDITION ROOM CREATED AT 3RD FLOOR PARTITION WALLS WEREE ERECTE... | $800 | -$391 | Apr 15, 2004 |
| Feb 24, 2004 | 34401497N | RESOLVE | Non-Hazardous | OCCUPANCY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY IN THAT C OFO #37776 STATED AT CELLAR STORAGE & SALE & 3RD ... | $800 | $0 | Apr 15, 2004 |
| Dec 11, 2002 | 34372468Y | RESOLVE | Non-Hazardous | WORK W/O PERMIT(S); WORK NOTED ERECTED A STRUCTURE ON ROOF APPROX 24' X 50' X 9'H. REMEDY : OBTIAN PERMIT IF POSSIBLE... | $0 | $0 | May 8, 2003 |
| Jul 5, 2002 | 34331051H | RESOLVE | Non-Hazardous | WORK WITHOUT PERMITS, WORK NOTED: AT ROOF LEVEL ERECTED A PENTHOUSE APPROX 15X22' LONG & 8'H PENT HOUSE FULLY OCCUPIE... | $0 | $0 | Sep 26, 2002 |