Skip to content

ECB violations

511-525 West 36 Street, Manhattan • Block 00708 • Lot 0020

27 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Mar 11, 2026 39179994L RESOLVE CLASS - 2 I OBSERVED IN ROOF TOP MECHANICAL ROOM, GAS REGULATORS ON MAIN HOUSE PIPE WERE NOT VENTED CORRECTLY ALLOWING GAS TO E... $3,125 $3,125 May 21, 2026
Nov 24, 2023 39100012Z RESOLVE CLASS - 2 1/X/10 EMERGENCY STOP SWITCH BELL DOES RING WHEN ACTIVATED INOPERATIVEREPAIR,98/M/7, 5 YEAR TAG MISSING PROVIDE, 59/X... $0 $0 Feb 1, 2024
Mar 1, 2019 35369440L RESOLVE CLASS - 1 BC3310.8.2.1 SITE SAFETY MANAGER FAILED TO NOTIFY THE DEPT OF UNSAFE CONDITIONS/ACCIDENT. AT THE TIME OF INSPECTION O... $1,250 $0 Sep 19, 2019
Feb 25, 2019 35363737P RESOLVE CLASS - 1 BC 3301.2 FAILURE TO INSTITUTE AND MAINTAIN SAFE OPERATIONS. NOTE:AT THE TIME OF MY INSPECTION OF AN ACTIVE JOBSITE,R... $2,530 $0 Apr 18, 2019
Nov 27, 2018 35377964M RESOLVE CLASS - 1 FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS.IN RESPONSE TO AN INCIDENT FOR THE ... $10,000 $0 Feb 7, 2019
Nov 27, 2018 35377963K RESOLVE CLASS - 1 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS.IN RESPONSE TO AN INCIDENT FOR TH... $2,500 $0 Feb 7, 2019
Jul 30, 2018 35343026K RESOLVE CLASS - 1 3304.7 REQUIRED MEANS OF EGRESS. AT TIME OF INSPECTION ON AN ACTIVE JOBSITE OF A 39 STORY BUILDING. OBSERVED THAT EGR... $2,500 $0 Sep 13, 2018
Jul 25, 2018 35345120X RESOLVE CLASS - 1 HOUSEKEEPING. @ TIME OF INSP OF A 39 STORY NB OBSERVED CERTAIN AREAS ON FLOORS 30 THROUGH 39 W/ INADEQUATE HOUSEKEEPI... $0 $0 Sep 13, 2018
May 10, 2018 35331118J RESOLVE CLASS - 1 BC3301.2.FAILURE TO HOLES COVERED.AT TIME OF INSPECTION OBSERVED ACTIVE JOB SITE.FAILURE TO MAINTAIN HOLES.COVERED WA... $2,500 $0 Jun 28, 2018
Feb 13, 2018 35301460H RESOLVE CLASS - 1 BC 3301.1.2 FAILURE TO HAVE FDNY PERMIT FOR PROPANE STORED ON SITE. NOTICED AT TIME OF INSPECTION NB IN PROGRESS NOTI... $1,600 $0 Apr 5, 2018
Dec 4, 2017 35285599P RESOLVE CLASS - 2 FAILURE TO SAFEGUARD ALL PESONS AND PROPERTY EFFECTED BY CONSTRUCTION OPERATIONS PARTIAL STOP WORK ON ALL BACKER SCAF... $5,000 $0 Jan 18, 2018
Dec 2, 2017 35300827K RESOLVE CLASS - 1 SEC: BC 3301.6. NO DRAWINGS (FALL ARREST SYSTEM). @ TIME OF INSP OF A 39 STORY BLDG CURRENTLY ON ROOF LEVEL, OBSERVED... $1,600 $0 Jan 19, 2018
Oct 15, 2017 35225432Z RESOLVE CLASS - 1 INADEQUATE SAFETY MEASURES WITH OPERATIONS OF CRANE/HOISTING EQUIPMENTIN UNSAFE MANNER.AT TIME OF INSPECTION I ASKED ... $10,000 $0 Jan 25, 2018
Oct 13, 2017 35225431R RESOLVE CLASS - 1 INADEQUATE SAFETY MEASURES WITH OPERATIONS OF CRANE/HOISTING EQUIPMENTIN UNSAFE MANNER.AT TIME OF INSPECTION I REQUES... $4,800 $0 Jan 25, 2018
Jan 4, 2017 35217393P RESOLVE CLASS - 2 JOB SITE FENCE NOT CONSTRUCTED TO CODE. NOTICED AT TIME OF INSPECTION JOB SITE FENCE ERECTED AT EXP#1 NOT TO CODE FEN... $0 $0 Feb 23, 2017
Jan 4, 2017 35217391L RESOLVE CLASS - 2 SEC. 3304.8 DEWATERING SITE W/O DEP PERMIT TO DEWATER. NOTICED AT TIMEOF INSPECTION NB IN PROGRESS. NOTICED AT EXP#1 ... $800 $0 Feb 23, 2017
Jan 4, 2017 35217392N RESOLVE CLASS - 2 SEC. 3307.2.1 DOT PERMIT NOT IN CONJUNCTION. NOTICED AT TIME OF INSPECTION NOTICED NB IN PROGRESS. NOTICED AT EXP#1 T... $0 $0 Feb 23, 2017
Apr 26, 2016 35174823Z RESOLVE CLASS - 2 FAILURE TO PROVIDE APPROVED/ACCEPTED PLANS AT THE JOBSITE. AT THE TIMEOF INSPECTION,THE RESPONDENT FAILED TO PROVIDE ... $0 $0 Jun 16, 2016
Apr 26, 2016 35174824K RESOLVE CLASS - 1 FAILURE TO NOTIFY THE DOB W/I 24-48HRS OF THE START OF EXCAVATION. AT THE TIME OF INSPECTION,THE EXCAVATION WORK HAD ... $1,200 $0 Jun 16, 2016
Dec 28, 2013 35087328X RESOLVE CLASS - 2 FAILURE TO POST DOT PERMIT FOR STREET CLOSING. A DEBRIS CONTAINER HAS BEEN PLACED IN STREET CLOSING CURB LANE OF W 36... $250 $0 Mar 20, 2014
Sep 29, 2013 35065242H RESOLVE CLASS - 2 JOB SITE FENCE NOT CONSTRUCTED OR MAINTAINED PURSUANT TO SUBSECTION. DEFECTS NOTED: CONSTRUCTION SITE FENCE ERECTED U... $0 $0 Nov 14, 2013
Sep 26, 2013 35019345N RESOLVE CLASS - 1 SEC. BC 3303.5.2. DROPPING OR THROWING PROHIBITED. AT THE TIME OF MY INSPECTION DEMO WORK IN PROGRESS APPROX 15 WORKE... $1,600 $0 Nov 14, 2013
Aug 16, 2013 35028953L RESOLVE CLASS - 1 SEC. BC 3306.2. FAILURE TO PROTECT UTILITY LINES OF ADJOINING BLDG - UPON INSPECTION DEMOLITION WORK OF 5 STY BLDG CO... $800 $0 Jan 23, 2014
Feb 24, 2004 34401498P RESOLVE Hazardous WORK WITHOUT A PERMIT HAZARDOUS WORK NOTED AT ROOF AN ADDITION ROOM CREATED AT 3RD FLOOR PARTITION WALLS WEREE ERECTE... $800 -$391 Apr 15, 2004
Feb 24, 2004 34401497N RESOLVE Non-Hazardous OCCUPANCY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY IN THAT C OFO #37776 STATED AT CELLAR STORAGE & SALE & 3RD ... $800 $0 Apr 15, 2004
Dec 11, 2002 34372468Y RESOLVE Non-Hazardous WORK W/O PERMIT(S); WORK NOTED ERECTED A STRUCTURE ON ROOF APPROX 24' X 50' X 9'H. REMEDY : OBTIAN PERMIT IF POSSIBLE... $0 $0 May 8, 2003
Jul 5, 2002 34331051H RESOLVE Non-Hazardous WORK WITHOUT PERMITS, WORK NOTED: AT ROOF LEVEL ERECTED A PENTHOUSE APPROX 15X22' LONG & 8'H PENT HOUSE FULLY OCCUPIE... $0 $0 Sep 26, 2002