ECB violations
485-499 10 Avenue, Manhattan • Block 00709 • Lot 0031
46 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Aug 5, 2019 | 38270672J | RESOLVE | CLASS - 1 | 5A10 CAR DOOR RESTRICTOR ALTERED OR REPAIR OR REPLACE (CAR DOOR RESTRICTOR IS NOT WORKING NEED PARTS REPAIR OR REPLACE). | $1,250 | $0 | Oct 3, 2019 |
| Apr 27, 2017 | 35237989Y | RESOLVE | CLASS - 2 | PSWO SUSPENDED SCAFFOLD.WORK DOES NOT CONFORM TO APPROVED CD-5.NOTED:@TIME OF INSPECTION THE APPROVED CD-5 SHOW A TIE... | $0 | $0 | Jun 15, 2017 |
| Mar 21, 2017 | 35237653K | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS. NOTED: @ TIME OF INSP THERE IS NO DETAIL FOR PIPE SCAFFOLD ... | $0 | $0 | May 11, 2017 |
| Feb 2, 2017 | 35200146R | RESOLVE | CLASS - 2 | SEC: 28.105.12.2. PSWO SUSPENDED SCAFFOLD WORK DOES NOT CONFORM TO APPROVED CD5 CONSTRUCTION DOCUMENTS. NOTED: @ TIME... | $250 | $0 | Mar 23, 2017 |
| Jan 20, 2010 | 34821247L | RESOLVE | CLASS - 2 | FAILED TO NOTIFY DEPT PRIOR TO USE/INST OF OUTRIGGER BEAMS IN CONNECTION WITH SUSPENDED SCAFFOLD. NOTED: NO NOTIFICAT... | $800 | $0 | Mar 11, 2010 |
| Sep 22, 2009 | 34786175K | RESOLVE | CLASS - 2 | SEC BC3314.4.4 STORAGE OF MATERIALS AND DEBRIS NOTED AT TIME OF INSP ON ACTIVE JOB SITE W/ BRICK LAYER INSTALLING BRI... | $0 | $0 | Nov 12, 2009 |
| Sep 22, 2009 | 34786176M | RESOLVE | CLASS - 2 | SEC BC3307.4.1 FAILURE TO PROVIDE REQUIRED WARNING SIGNS & LIGHTS AT TIME OF INSP ON ACTIVE JOB SITE W/ BRICK FACADE ... | $0 | $0 | Nov 12, 2009 |
| Jun 3, 2009 | 34768529J | RESOLVE | CLASS - 2 | WORK CONTRARY TO APPROVED PLAN AND APPLICATION AND OR APPROVED AMENDMENTS UPON INSPECTION CONSTRUCTION OF NB IS IN PR... | $0 | $0 | Jul 23, 2009 |
| Apr 29, 2009 | 34768506R | RESOLVE | CLASS - 1 | SEC.3308.1.1 VERTICAL SAFETY NETTING NOT PROVIDED & MAINTAINED.UPON INSPECTION CONSTRUCTION OF NB IN PROGRESS.AT TIME... | $1,600 | $0 | Nov 5, 2009 |
| Apr 29, 2009 | 34768505P | RESOLVE | CLASS - 1 | RESHORES NOT SECURED - UPON INSPECTION CONSTRUCTION OF NB IN PROGRESS.AT TIME OF INSPECTION NOTED SEVERAL RESHORES ON... | $0 | $0 | Nov 5, 2009 |
| Apr 29, 2009 | 34768504N | RESOLVE | CLASS - 1 | SEC.3303.4.5.1 UNSAFE STORAGE OF MATERIALS UPON INSPECTION NOTED MATERIALS LIKE BATHTUB STORED LESS THAN 10FT FROM TH... | $1,600 | $0 | Nov 5, 2009 |
| Apr 29, 2009 | 34768507Z | RESOLVE | CLASS - 1 | FAILURE TO INSTITUTE/MAINTAINED SAFETY EQUIPMENT MEASURES OR TEMPORARYCONSTRUCTION.NO HANDRAIL-UPON INSPECTION NOTED ... | $0 | $0 | Nov 5, 2009 |
| Apr 15, 2009 | 34768166J | RESOLVE | CLASS - 1 | FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION - NO HANDRAIL - UPON INSPECTION NOT... | $1,000 | $0 | Sep 4, 2009 |
| Apr 15, 2009 | 34768164X | RESOLVE | CLASS - 1 | SEC. 3303.4.5.1. UNSAFE STORAGE OF MATERIALS ON FLRS LESS THAN 10' FROM THE EDGE - UPON INSPECTION CONSTRUCTION OF NB... | $0 | $0 | Sep 4, 2009 |
| Apr 15, 2009 | 34768165H | RESOLVE | CLASS - 1 | SEC. 1906. RESHORES NOT SECURED - UPON INSPECTION CONSTRUCTION OF NB IN PROGRESS. AT TIME OT INSPECTION OBSERVED 42ND... | $0 | $0 | Sep 4, 2009 |
| Mar 20, 2009 | 34759349H | RESOLVE | CLASS - 2 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTIONOPERATIONS. RECENT SMOKING REFUSE OBSERVED W/I ... | $0 | $0 | May 14, 2009 |
| Mar 20, 2009 | 34768900P | RESOLVE | CLASS - 2 | SEC. BC 3301.2;27-1009(A). FAILURE TO SAFEGUARD ALL PERSONS & PROPERTYAFFECTED BY CONSTRUCTION OPERATION. NOTED: AT T... | $0 | $0 | May 14, 2009 |
| Feb 24, 2009 | 34759144Y | RESOLVE | CLASS - 1 | FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES - NO TOE BOARDHOLES IN FLOORS- UPON INSPECTION NOTED HOLES & ... | $1,000 | $0 | Jul 21, 2009 |
| Feb 24, 2009 | 34759145X | RESOLVE | CLASS - 1 | SEC 3303.4.5.1 MISC VIOL: UNSAFE STORAGE OF MATERIALS AT THE EDGE OF FLOORS. UPON INSPECTION OBSERVED ONE STALK OF TE... | $1,600 | $0 | Jul 21, 2009 |
| Feb 24, 2009 | 34759143M | RESOLVE | CLASS - 1 | FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES - NO TOE BOARDUPON INSPECTION CONSTRUCTION OF NB IS IN PROGRE... | $1,000 | $0 | Jul 16, 2009 |
| Jan 22, 2009 | 34758695X | RESOLVE | CLASS - 1 | FAILURE TO INSTITUTE AND MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION: HOLES IN FLOOR. UPON INSPECTIO... | $1,000 | $0 | Mar 12, 2009 |
| Jan 22, 2009 | 34758696H | RESOLVE | CLASS - 1 | PROVISION 27-1018(B) STORAGE OF MATERIAL DURING CONSTRUCTION: UPON INSPECTION AS NOTED ON ACTIVE JOB SITE UP TO 23RD ... | $1,600 | $0 | Mar 12, 2009 |
| Jan 22, 2009 | 34758694Y | RESOLVE | CLASS - 2 | FAILURE TO SAFEGUARD ALL PERSON'S AND PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. UPON INSPECTION AS OBSERVED RECEN... | $0 | $0 | Mar 12, 2009 |
| Dec 29, 2008 | 34750113K | RESOLVE | CLASS - 2 | SEC BC3301.9.1 27-04 FAILURE TO PROVIDE A SIGN W/ WORDING TO ANONYMOUSLY REPORT UNSAFE CONDITIONS AT THIS WORK SITE T... | $400 | $0 | Feb 12, 2009 |
| Dec 29, 2008 | 34750114M | RESOLVE | CLASS - 2 | SEC 28-407.1 FAILURE TO PROVIDE VALID WELDING LICENSE NOTE AT TIME OF INSP AT ABOVE ACTIVE CONSTRUCTION SITE CONCRETE... | $400 | $0 | Feb 12, 2009 |
| Dec 4, 2008 | 34749757H | RESOLVE | CLASS - 1 | SEC. 3303.4.5.1;27-1018(B). UNSAFE STORAGE OF MATERIALS AT THE EDGE OFTHE FLS - UPON INSPECTION CONSTRUCTION OF NB IS... | $1,600 | $0 | Jan 21, 2010 |
| Dec 4, 2008 | 34749762M | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATION - UPON INSPECTION OBSERVED 8TH FL SETB... | $2,400 | $0 | Apr 16, 2009 |
| Dec 4, 2008 | 34749758J | RESOLVE | CLASS - 1 | SEC. 3303.12;27-1014(B). NO ELEVATOR IN READINESS - UPON INSPECTION CONSTRUCTION OF NB IS IN PROGRESS, THE EAST TOWER... | $0 | $0 | Jan 21, 2010 |
| Dec 4, 2008 | 34749760Z | RESOLVE | CLASS - 1 | SEC. 3308.1.1;27-1021(G)(3). VERTICAL SAFETY NETTING DEFECTIVE - UPON INSPECTION, CONSTRUCTION OF NB IS AT 15 FL POUR... | $1,600 | $0 | Jan 21, 2010 |
| Dec 4, 2008 | 34749759L | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATION - UPON INSPECTION OBSERVED CONTRACTOR ... | $1,200 | $0 | Jan 21, 2010 |
| Nov 19, 2008 | 34714973M | RESOLVE | CLASS - 1 | SEC 3301.2 FAILURE TO COMPLY W/THE NYC FIRE CODE-NO FIRE GUARD. AT THETIME OF INSP ON AN ACTIVE CONST SITE, ON 9TH FL... | $1,600 | $0 | May 8, 2009 |
| Nov 19, 2008 | 34714972K | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS AND PROP AFFECTED BY CONST OPERATIONSAT THE TIME OF INSP, 12TH FL IS BEING FORMED OF... | $2,400 | $0 | Jan 8, 2009 |
| Nov 19, 2008 | 34714971Z | RESOLVE | CLASS - 1 | SEC 3303.6.1 MISC VIOL: FAILURE TO PROVIDE REQUIRED LADDERS FOR ESCAPEHATCH. AT THE TIME OF INSP 10TH FL OF W.SIDE TO... | $1,600 | $0 | Jan 8, 2009 |
| Nov 13, 2008 | 34714960N | RESOLVE | CLASS - 2 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONST OPERATIONS OBSERVED RECENT SMOKING REFUSE WITHIN CONS... | $0 | $0 | Jan 8, 2009 |
| Oct 16, 2008 | 34706109J | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTIONOPERATIONS. AT TIME OF INSPECTION ON ACTIVE CON... | $2,400 | $0 | Dec 11, 2008 |
| Oct 16, 2008 | 34706110R | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTIONOPERATIONS. AT TIME OF INSPECTION ON ACTIVE CON... | $2,400 | $0 | Dec 11, 2008 |
| Oct 9, 2008 | 34714933H | RESOLVE | CLASS - 1 | OPENING/HOLES NOT COVER. AS NOTED: AT TIME OF INSPECTION ON AN ACTIVE CONSTRUCTION SITE. BLDG UP TO 4 FLR DECK EAST B... | $1,000 | $0 | Dec 11, 2008 |
| Oct 9, 2008 | 34714930M | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVEDD CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENT. AS NOTED: AT TIME OF INSPECTION ... | $0 | $0 | Dec 11, 2008 |
| Oct 9, 2008 | 34714932X | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN (GUARDRAIL). AS NOTED: AT TIME OF INSPECTION ON ANACTIVE CONSTRUCTION SITE, BLDG UP TO 4 STORIES ... | $0 | $0 | Dec 11, 2008 |
| Oct 9, 2008 | 34714931Y | RESOLVE | CLASS - 2 | FAILURE TO SAFEGUARD ALL PERSON & PROPERTY AFFECTED BY CONSTRUCTION OPERATION. AS NOTED: AT TIME OF INSPECTION ON AN ... | $1,200 | $0 | Dec 11, 2008 |
| Sep 25, 2008 | 34706105M | RESOLVE | CLASS - 1 | FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMP CONSTRUCTION. NO GUARDRAIL AT TIME OF INSPECTION FORM... | $2,400 | $0 | Mar 19, 2009 |
| Sep 3, 2008 | 34689644J | RESOLVE | CLASS - 2 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTIONAT THE TIME OF INSP ON AN ACTIVE CONSTRUCTION S... | $1,200 | $0 | Jan 15, 2009 |
| Aug 26, 2008 | 34689626X | RESOLVE | CLASS - 1 | SEC. 28-3301.2 & 27-1009(A). OPENINGS NOT COVERED. AT THE TIME OF INSPECTION ON AN ACTIVE CONSTRUCTION SITE, 3RD FL F... | $1,600 | $0 | Jan 20, 2009 |
| Jun 11, 2008 | 34644461H | RESOLVE | Hazardous | FAILURE TO HAVE SITE SAFETY MANAGER PRESENT AS REQUIRED AS NOTED: AT TIME OF INSPECTION ON AN ACTIVE CONSTRUCTION SIT... | $2,000 | $0 | Nov 6, 2008 |
| Nov 22, 2002 | 34372570K | RESOLVE | Non-Hazardous | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION NOTED: ILLEGAL STRUCTURE STILL AT THI... | $2,500 | $0 | Jan 9, 2003 |
| Mar 10, 1989 | 34021571H | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT WORK NOTED DEMOLISHING BUILDING AT WEST WALL REMOVED ALL ROOFING MATERIALS AND PARAPET WALL REM... | $250 | $0 | Apr 27, 1989 |