ECB violations
476-490 11 Avenue, Manhattan • Block 00710 • Lot 0001
24 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Mar 25, 2026 | 39181803M | RESOLVE | CLASS - 2 | VF... HOIST MACHINE BRAKE MAINTENANCE TAG EXPIRED PROVIDE.. 59-BB-7... | $0 | $0 | Jun 4, 2026 |
| Mar 25, 2026 | 39181802K | RESOLVE | CLASS - 2 | VF... HOIST MACHINE BRAKE MAINTENANCE TAG EXPIRED PROVIDE.. 59-BB-7... CAR DOOR MISALIGNED ADJUST.. 5-J-1.. | $0 | $0 | Jun 4, 2026 |
| Mar 25, 2026 | 39181801Z | RESOLVE | CLASS - 2 | VF.. HOIST MACHINE BRAKE MAINTENANCE TAG EXPIRED PROVIDE...59-BB-7.. CAR DOOR MISALIGNED ADJUST...5-J-1... | $0 | $0 | Jun 4, 2026 |
| Oct 19, 2021 | 35587659L | RESOLVE | CLASS - 2 | SWS PARAPET PANEL INFO SIGN ATO MY INSP OF PROPOSED 52STYNB I OBSERVEDSWS IN PLACE@EXP1,2,3.THIS SHED HAD 1PROJECT IN... | $0 | $0 | Jan 20, 2022 |
| Oct 19, 2021 | 35587660Z | RESOLVE | CLASS - 1 | NO HANDRAILS ATO MY INSP OF PROPOSED 52STYNB I OBSERVED STAIRS LEADINGTO/FROM 1FL TO CELLAR W/NO HANDRAIL IN PLACE.TH... | $2,500 | $0 | May 26, 2022 |
| Jun 7, 2021 | 35557455M | RESOLVE | CLASS - 2 | BC3301.2 HOLES/OPENING NOT/INADEQUATELY COVERED.NOTED:AT TIME OF INSPECTION OF A NEW 52 STORY BUILDING CONSTRUCTION I... | $0 | $0 | Aug 19, 2021 |
| Feb 18, 2021 | 35552151K | RESOLVE | CLASS - 2 | WORK DOESN'T CONFORM TO APPROVED CONST DOCS OR APPROVED DRAWINGS.NOTE:@TIME OF MY INSP OF 52STYNB ACTIVE JOBSITE,I OB... | $620 | $0 | May 6, 2021 |
| Dec 8, 2020 | 39033150J | RESOLVE | CLASS - 2 | TOWER CRANE TIE-IN # 2 ON THE 25TH FL FOR PHASE 4 SHOULD BE RELEASED COMPLETELY AS PER APPROVED DRAWINGS SUBMITTED,IN... | $620 | $0 | Jan 28, 2021 |
| Sep 26, 2020 | 35499363M | RESOLVE | CLASS - 1 | SEC. BC 3303.4.1 FAILURE TO MAINTAIN HOUSEKEEPING. NOTE: AT TIME OF MYINSPECTION OF A PROPOSED 52 STY'S NEW BLDG UNDE... | $625 | $0 | May 6, 2021 |
| Jul 27, 2020 | 39026000Z | RESOLVE | CLASS - 1 | HMO JOHNNY URENA #9534 DID NOT ATTEND MANDATORY PRE-TASK HOISTING MEETING ON 7/27/20. IT IS REQUIRED THAT THE HMO IS ... | $0 | $0 | Jun 10, 2021 |
| Jul 27, 2020 | 35500354X | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY @TIME OF MY INSPECTION. NEW BLDG OF 52 STY UNDER CONST OF THE... | $0 | $0 | Jun 10, 2021 |
| Jul 27, 2020 | 35500356J | RESOLVE | CLASS - 1 | FALL POTRECTION @TIME OF MY INSPECTION OF NEW BUILDING OF 52 STY WITH PERPORATIONS FOR 16TH FLOOR ROOF CONCRETE FORM ... | $0 | $0 | Jun 10, 2021 |
| Jul 27, 2020 | 39025989P | RESOLVE | CLASS - 1 | LIFT DIRECTOR OF CD4726 UNDER CN838/19, KEIF GONZALEZ, FAILED TO PERFORM DUTIES AS LIFT DIRECTOR. MR. GONZALEZ IS RES... | $0 | $0 | May 13, 2021 |
| Jul 27, 2020 | 35500357L | RESOLVE | CLASS - 1 | FAILURE TO FILE EVIDENCE OF LIABILITY AND/OR PROPERTY DAMAGE.AT TIME OF MY INSPECTION,NB OF 52 STORY W/ PREPARTIONS F... | $0 | $0 | Apr 8, 2021 |
| Jul 27, 2020 | 35500358N | RESOLVE | CLASS - 1 | FAILURE TO FILE EVIDENCE OF COMPLIANCE WITH DISABILITY BENEFITS LAW.UPON TIME OF INSPECTION,NB OF 52 STORY WITH PREPA... | $0 | $0 | Apr 8, 2021 |
| Jul 27, 2020 | 35500355H | RESOLVE | CLASS - 1 | VERTICAL SAFETY NETTING SYSTEM.AT TIME OF MY INSPECTION OF NB OF 52 STORY WITH PREPARTIONS FOR 16TH FL ROOF CONCRETE ... | $2,500 | $0 | Jul 8, 2021 |
| Jul 27, 2020 | 39025988N | RESOLVE | CLASS - 1 | HIGHBURY CONCRETE INC, USER OF TOWER CRANE CD4726 UNDER CN838/19 WAS HOISTING SHORING COLUMNS ON PERIMETER OF BUILDIN... | $0 | $0 | May 13, 2021 |
| Jul 7, 2020 | 35488004R | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED PLANS.NOTED:AT TIME OF INSPECTION LOCATRON OF THE MOBILE CRANE THAT PLACED AT W 39 ... | $1,250 | $0 | Sep 17, 2020 |
| Jun 27, 2020 | 35411475H | RESOLVE | CLASS - 1 | WRITTEN TO EOR.CRANE PLANS DO NOT SHOW PERTINENT FEATURES & ACTUAL SITE CONDITIONS REQUIRED TO BE SHOWN ON THESE DOCU... | $2,530 | $0 | Jan 28, 2021 |
| Jun 26, 2020 | 35481503J | RESOLVE | CLASS - 1 | FAILURE TO PERFORM HYDROSTATIC PRESSURE TEST OF STANDPIPE. NOTED: AT TIME OF MY INSPECTION OF A PROPOSED 52 STY N.B. ... | $5,000 | $0 | May 5, 2022 |
| Jun 2, 2020 | 35491458Z | RESOLVE | CLASS - 1 | WORK DOES NOT CONFORM TO APPROVED SITE SAFETY PLAN NOTE:AT THE TIME OFMY INSPECTION OF A 52 STORY BUILDING CONSTRUCTI... | $0 | $0 | Dec 17, 2020 |
| Mar 10, 2020 | 35472314X | RESOLVE | CLASS - 2 | JOB SITE FENCE NOT CONSTRUCTED OR MAINTAINED PURSUANT TO SUBSECTION.ATTIME OF MY INSPECTION ON AN NB ACTIVE JOB SITE ... | $500 | $0 | May 21, 2020 |
| Feb 10, 2020 | 35472025J | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PUBLIC AND PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. NOTE:AT THE TIME OF MY INSPECTION R... | $0 | $0 | Jan 28, 2021 |
| Oct 31, 2019 | 35460271R | RESOLVE | CLASS - 1 | BC3303411-SIDEWALK MAINTENANCE.AT TIME OF INSPECTION,I OBSERVED THE SIDEWALK AT EXPOSURE#2(11TH AVENUE AND 39TH STREE... | $0 | $0 | Jan 9, 2020 |