ECB violations
442-454 West 31 Street, Manhattan • Block 00728 • Lot 0060
53 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Apr 24, 2024 | 39527927J | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION OBSERVE SIDEWALK SHED ERECTED AT EXPOSURE-1 OBSERVE THE MISSING PARAPET PANELS AT EXPOSURE#1 AN... | $2,400 | $0 | Jul 11, 2024 |
| Apr 4, 2023 | 39082987M | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. AT TIME OF INSPECTION OBSERVED AT 1ST FLOOR COMMERCIAL SPACE E... | $1,250 | $0 | Nov 9, 2023 |
| Oct 12, 2022 | 39507447M | RESOLVE | CLASS - 2 | AT THE TIME OF INSPECTION 12 STORIES ALT BUILDING I OBSERVED SUSPENDED SCAFFOLD ON ROOF LEVEL AND WORKERS ON THE PLAT... | $625 | $0 | Dec 1, 2022 |
| Oct 12, 2022 | 39507446K | RESOLVE | CLASS - 2 | AT THE TIME OF INSPECTION 12 STORIES ALTERATION I OBSERVED SUSPENDED SCAFFOLD ON ROOF LEVEL WITH HAVING PARAPET CLAMP... | $0 | $0 | Dec 1, 2022 |
| Jul 26, 2022 | 39066688M | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLAINT MANNER I OBSERVED IN THE BASEMENT BY THE GAS METERS HAVING A FUTURES O... | $1,250 | $0 | Sep 15, 2022 |
| Mar 14, 2022 | 35647344Z | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE ADEQUATE SAFETY MEASURES TO PROTECT PUBLIC FROM A DOCUMENTED UNSAFE FACADE.AS NOTED BUILDING FAILE... | $10,000 | $0 | Mar 9, 2023 |
| Jan 24, 2022 | 35640202L | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE SAFETY MEASURES TO PROTECT PUBLIC FROM A DOCUMENTEDUNSAFE FACADE.AS NOTED BLDG FAILED TO MAKE STEP... | $0 | $0 | Sep 7, 2023 |
| Dec 9, 2021 | 35635298Z | RESOLVE | CLASS - 1 | REISSUE ECB#35635481R ISSUED ON 10/28/2021.FAILURE TO PROVIDE ADEQUATESAFETY MEASURES SUCH AS SHED NETTING ETC WHERE ... | $0 | $0 | Apr 20, 2023 |
| Oct 28, 2021 | 35635481R | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE ADEQUATE SAFETY MEASURES,SUCH AS SHED NETTING ETC WHERE REQUIRED TO PROTECT AND SECURE PUBLIC SAFE... | $10,000 | $0 | Feb 9, 2023 |
| Jul 6, 2021 | 39044157X | RESOLVE | CLASS - 2 | MISSING MANUAL RESET LOW WATER CUT OFF-AT LEAST ONE MUST BEMANUAL RESET TYPE. AS PER-MC 1007.2/ASME CSD1. VENTING MAT... | $625 | $0 | Nov 18, 2021 |
| Jan 6, 2021 | 35542413M | RESOLVE | CLASS - 1 | FAILURE TO REPAIR SWARMP CONDITIONS IN A TIMELY MANNER.OWNER FAILED TO REPAIR "REPAIR OF CRACKS WITHIN THE TERRA COTT... | $1,250 | $0 | Apr 8, 2021 |
| Sep 21, 2020 | 35520364H | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION#35476089R ISSUED ON 3/6/20 AND TO FILE... | $1,250 | $0 | Jul 15, 2021 |
| Mar 6, 2020 | 35476089R | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS NOTED AT TIME OF INSPECTION I OBSERVE... | $2,500 | $0 | Jul 15, 2021 |
| Jan 11, 2020 | 35467658N | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTION.OPERATIONS AT THE TIME OF INSPECTION NOTED AT ... | $10,000 | $0 | May 27, 2021 |
| Nov 18, 2019 | 35433538N | RESOLVE | CLASS - 1 | BC3314-SUPPORTED SCAFFOLD DOES NOT MEET D.O.B SPECIFICATIONS.AS NOTED SUPPORTED SCAFFOLD AT 10 FLOOR TO 12 FLOOR HAS ... | $6,250 | $0 | Jan 23, 2020 |
| Oct 15, 2018 | 37013273Z | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT A REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPUR... | $3,125 | $0 | Mar 21, 2019 |
| Jul 1, 2014 | 36019491H | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE CYCLE 7 TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS: PERIODIC INSPECTION OF EXT... | $4,000 | $0 | Nov 6, 2014 |
| Jun 30, 2014 | 38232026H | RESOLVE | CLASS - 2 | 42G11 41R11 41T07 60B07 67L10. 42G11-REPLACE INSUFFICENT FUSES. 41R11-REPLACE EMR DOOR NHH SELF-CLOSING SELF-LOCKING.... | $2,500 | $0 | Aug 14, 2014 |
| Feb 7, 2014 | 38229531L | RESOLVE | CLASS - 3 | 56Y13,41B7,100L10. 56Y13-HOIST MACHINE HAS OIL LEAK SEAL MACHINE; 41B7PROVIDE SELF CLOSING, SELF LOCKING MACHINE ROOM... | $500 | $0 | Mar 27, 2014 |
| Jun 25, 2012 | 34997600M | RESOLVE | CLASS - 1 | OAC SIGN PROHIBITED IN C6-4 ZONE. (YANKEES.COM). REMEDY: REMOVE ILLEGAL SIGN. | $10,000 | $0 | Aug 22, 2013 |
| Jun 25, 2012 | 34983599R | RESOLVE | CLASS - 1 | OAC SIGN ON DISPLAY W/O A PERMIT. (YANKEES.COM) REMEDY: REMOVE ILLEGALSIGN. | $10,000 | $0 | Aug 22, 2013 |
| Jun 25, 2012 | 34983598P | RESOLVE | CLASS - 1 | OAC SIGN ON DISPLAY W/O A PERMIT. (YANKEES.COM). REMEDY: REMOVE ILLEGAL SIGN. | $10,000 | $0 | Aug 22, 2013 |
| Jun 25, 2012 | 34997604J | RESOLVE | CLASS - 1 | OAC FAILURE TO HAVE LICENSED SIGN HANGER ATTACH OR ERECT SIGN. (YANKEES.COM) REMEDY: REMOVE ILLEGAL SIGN. | $0 | $0 | Jul 19, 2013 |
| Jun 25, 2012 | 34997605L | RESOLVE | CLASS - 1 | OAC FAILURE TO HAVE LICENSED SIGN HANGER ATTACH OR ERECT SIGN. (YANKEES.COM). REMEDY: REMOVE ILLEGAL SIGN. | $0 | $0 | Aug 22, 2013 |
| Jun 25, 2012 | 34997606N | RESOLVE | CLASS - 1 | OAC FAILURE TO HAVE LICENSED SIGN HANGER ATTACH UL CLASSIFICATION MARKOR DATE OF SIGN'S ERECTION TO CORNER OF SIGN FA... | $0 | $0 | Jul 19, 2013 |
| Jun 25, 2012 | 34997607P | RESOLVE | CLASS - 1 | OAC FAILURE TO HAVE LICENSED SIGN HANGER ATTACH UL CLASSIFICATION MARKOR DATE OF SIGN'S ERECTION TO CORNER OF SIGN FA... | $0 | $0 | Aug 22, 2013 |
| Jun 25, 2012 | 34997602X | RESOLVE | CLASS - 1 | OAC FAILURE TO REGISTER SIGN W/I 900' OF MAPPED ARTERIAL OF LINCOLN TUNNEL. (YANKEES.COM). REMEDY: REMOVE ILLEGAL SIGN. | $0 | $0 | Aug 22, 2013 |
| Jun 25, 2012 | 34997601Y | RESOLVE | CLASS - 1 | OAC SIGN PROHIBITED IN C6-4 ZONE. (YANKEES.COM). REMEDY: REMOVE ILLEGAL SIGN. | $10,000 | $0 | Aug 22, 2013 |
| Jun 25, 2012 | 34997608R | RESOLVE | CLASS - 1 | PROPERTY OWNER ACTING AS OAC FAILURE TO OBTAIN OAC REGISTRATION # WHILE ENGAGING IN THE OUTDOOR AD BUSINESS. (YANKEES... | $0 | $0 | Aug 22, 2013 |
| Jun 25, 2012 | 34997603H | RESOLVE | CLASS - 1 | OAC FAILURE TO REGISTER SIGN W/I 900' OF MAPPED ARTERIAL OF LINCOLN TUNNEL. (YANKEES.COM). REMEDY: REMOVE ILLEGAL SIGN. | $0 | $0 | Sep 5, 2013 |
| Oct 20, 2008 | 38191784Z | RESOLVE | CLASS - 2 | 60X10.41M07.61L10.100D06.100M10.09V 60X10 REPAIR LIGHTS IN MOTOR RM 41M07 PROVIDE MISSING DOOR CLOSURE 61L10 REPAIR M... | $500 | $0 | Dec 11, 2008 |
| Feb 4, 2008 | 38181332Z | RESOLVE | Hazardous | 41G07.41D06.43H10.51O02.58O11.55Y13.56Y13.09I10.13X10.84X10.38O02.38Q03 41 PROPERLY FUSE CONTROLLER & SECURE CAPACITO... | $350 | $0 | Mar 27, 2008 |
| Feb 4, 2008 | 38181333K | RESOLVE | Hazardous | 03E10.84M07. 03 CAR RUBBING WHILE AT TOP LANDING REPAIR 84 PROVIDE HOITWAY SIGN FOR ALL WINDOWS IN HOISTWAY | $350 | $0 | Mar 27, 2008 |
| Apr 27, 2007 | 32053727Z | RESOLVE | Non-Hazardous | B4A,16,24B,32A,34A,38,50,50A,B,C,D,E.50-MODULAR BOILES MISSING RATTLING PLATE.50A-MODULE FLUES MANIFOLDED TOGETHER(MA... | $180 | $0 | Jun 21, 2007 |
| Oct 12, 2003 | 34415953P | RESOLVE | Hazardous | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE DOB RECORDS ILLEGAL OCCUPANCY NOTED PHOTO/VIDEO STUDIO IS BEING USE AS A PL... | $800 | -$1,700 | Jan 22, 2004 |
| Oct 12, 2003 | 34415954R | RESOLVE | Non-Hazardous | OPERATION OF A PLACE OF ASSEMBLY CONTRARY TO THE COFO OR DOB RECORDS WHEN THE CURRENT COFO OR DOB RECORDS DOES NOT AL... | $180 | $0 | Dec 4, 2003 |
| Jun 20, 2000 | 38099127R | RESOLVE | Non-Hazardous | 54R09. 54- REMOVE DEVICE FROM MAIN LINE SUPPLY MAIN LINE SUPPLY FOR ELEVATOR USE ONLY. | $350 | $0 | Sep 28, 2000 |
| Jun 20, 2000 | 38099128Z | RESOLVE | Non-Hazardous | 35I11/35O02/40O02/73T16/53I11/36I11/ 35- REPAIR DAMAGED SKY-LIGHT; REMOVE BUCKETS OF WATER FROM MOTOR ROOM. 35 CLEAN ... | $350 | $0 | Sep 28, 2000 |
| Jan 13, 1999 | 38083454H | RESOLVE | Non-Hazardous | 37G 46Q 35O 50Y 74O 37G12 PROPERLY FUSE CONTROLLER 46Q03 INSTALL ROPE FUSED FRONT 35 002 CLEAN MOTOR ROOM 50 414 SEAL... | $0 | $0 | Mar 4, 1999 |
| Aug 28, 1995 | 34128892Z | RESOLVE | Non-Hazardous | ALTERED BLDG OCCUPIED WITHOUT A VALID C OF O. 8 THRU 12 FLOORS.ALTERNATION#304-81.REMEDY:OBTAIN A VALID C OF O. | $0 | $0 | Dec 14, 1995 |
| Jul 27, 1994 | 34106710L | RESOLVE | Non-Hazardous | FAILURE TO FILE A REPORT OF COMPLIANCE WITH LOCAL LAW 16/84 CERTIFYING TO THE INSTALLATION OF REQUIRED FIRE PROTECTIO... | $500 | $0 | Sep 22, 1994 |
| Feb 25, 1994 | 38038497P | RESOLVE | Non-Hazardous | 36D,46H,50Y. | $200 | $0 | May 19, 1994 |
| Feb 25, 1994 | 38038496N | RESOLVE | Non-Hazardous | 05I,18D,46T,74R. 05 WEST GATE. 74 KEY BY PASS SWITCH. | $200 | $0 | May 19, 1994 |
| Sep 23, 1993 | 34087701Z | RESOLVE | Non-Hazardous | FAILURE TO FILE A REPORT OF COMPLIANCE WITH LOCAL LAW 16/84 CERTIFYINGTO THE INSTALLATION OF REQUIRED FIRE PROTECTION... | $400 | $0 | Jan 13, 1994 |
| Sep 23, 1993 | 34087702K | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE ADEQUATE EMERGENCY POWER EXIT LIGHTS PURSUANT TO BEC STANDARDS. FAILURE TO PROVIDE ADEQUATE EMERGE... | $800 | $0 | Jan 13, 1994 |
| Jul 22, 1992 | 38025969L | RESOLVE | Hazardous | 05I,18B,42F | $500 | $0 | Oct 22, 1992 |
| Apr 25, 1992 | 34064735P | RESOLVE | Non-Hazardous | FAILURE TO FILE A REPORT OF COMPLIANCE WITH LOCAL LAW 16/84 CERTIFYING TO THE INSTALLATION OF REQUIRED FIRE PROTECTIO... | $500 | $0 | Jun 11, 1992 |
| Mar 25, 1992 | 34064677X | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE DURABLE ELEVATOR LANDING SIGNS THROUGHOUT FLOORS. FAILURE TO PROVIDE FLOOR NUMBERING SIGNS THROUGH... | $1,500 | $0 | May 7, 1992 |
| Mar 25, 1992 | 34064676Y | RESOLVE | Non-Hazardous | FAILURE TO PROVIDE EMERGENCY POWER EXIT LIGHT. THROUGHOUT FLOOR AREAS (NOT INCLUDING STAIRCASE). FAILURE TO PROVIDE E... | $1,500 | $0 | May 7, 1992 |
| Aug 20, 1991 | 38015812Y | RESOLVE | Non-Hazardous | 15L; 15.RENEW OR REPAIR BASEMENT SHAFT DOOR. | $1,000 | $0 | Oct 3, 1991 |