DOB violation Jan 26, 2018
ACC1-(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION ELEVATORREQUIRED
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST
-
DOB violation Jan 26, 2018
ACC1-(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION ELEVATORREQUIRED
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST
-
DOB violation Jan 26, 2018
ACC1-(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION ELEVATORREQUIRED
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST
-
DOB violation Jan 26, 2018
ACC1-(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION ELEVATORREQUIRED
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST
-
DOB violation Jan 26, 2018
ACC1-(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION ELEVATORREQUIRED
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST
2016
-
DOB violation Nov 14, 2016
ACC1-(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION ELEVATORREQUIRED
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2014 CAT 1 INSP/TST
2015
-
Alteration Type II
PROPOSE TO PERFORM INTERIOR RENOVATIONS AS PER PLANS FILED HEREWITH. NO CHANGE TO ZOING, USE, EGRESS OR OCCUPANC Y.
2011
2009
2006
-
Alteration Type II
PROPOSE TO INSTALL NEW A/C EQUIPMENT AND PLUMBING FIXTURES AS APER PLANS FILED HEREWITH. NO CHANGE TO ZONING, USE EGR...
2005
-
Alteration Type II
PROVIDE MECHANICAL VENTILIATION AND PLUM BING AS PER PLANS. NO CHANGE TO EGRESS, OCCUPANCY, ZONING OR USE.
2004
-
Alteration Type II
PROVIDE SPRINKLERS AS PER PLANS FILED NO CHANGE IN USE, EGRESS OR OCCUPANCY.
2003
-
Alteration Type II
FILED HEREWITH IS FIRE PROTECTION PLAN I N CONJUNCTION WITH ALT TYPE I #101629374.
-
Non-Hazardous
54L10-37P11-38I11-31B07-48L12-16B09. 54-REPAIR OR REPLACE CRACKED BRAKE DRUM CEASE USE UNTIL THIS IS ACCOMPLISHED THE...
2002
-
Non-Hazardous
47B15-05D01-11D06-73P07. 47-SHORTEN GOVERNOR CABLE 05-ADJUST CAR DOOR CLOSE GAP OR DOOR) 11-INSTBELL GUARD OVER CAR L...
2001
-
Non-Hazardous
40O02/ 47J01/ 50O02/ 03B06/ 74O02/ 40O02 GOVENOR SHAVE DIRTY WITH GREASE 47J01 CABLE OUT OF A LIGNMENT WITH GOVERNOR ...
-
Non-Hazardous
FAILURE TO PROVIDE APPROVED PLANS AT PREMISE AT TIME OF INSPECTION. NOTED: RENOVATION WORK AND SOME DEMO BEIGN DONE O...
2000
-
Hazardous
OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OF O #29656,ISSUED FEBRUARY 6,1943,FOR LEGAL USE STORES.NOW CURRENTLY OCC...
-
Hazardous
OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OF O #29888, ISSUED 2-6-43: FOR LEGAL USE SOTRES, BUT CURRENTLY OCCUPIED ...
The most recent 6 events from each dataset, so no one source takes the axis. Each tab holds the full record.
Property Contacts
Contact information aggregated from multiple government sources
Building Permits
Owner information from Department of Buildings filings
Deed Records
Parties from ACRIS deed and mortgage records
Property Records
Owner information from assessment and PLUTO records