ECB violations
545-551 8 Avenue, Manhattan • Block 00761 • Lot 0033
64 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Aug 19, 2023 | 39520757Y | RESOLVE | CLASS - 2 | AT THE TIME OF MY INSPECTION I OBSERVED SIDEWALK SHED INSTALLED AT EXPOSURE #1 UPPON RESEARCH OF DEPARTMENT RECORDS P... | $1,280 | $0 | Jun 27, 2024 |
| Mar 2, 2023 | 39513723K | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION 25 STORY FACADE AND BALCONY REPAIR ALTERATION CLOSED SITE OBSERVED PIPE SCAFFOLD AT REAR IN PLA... | $0 | $0 | May 11, 2023 |
| Mar 2, 2023 | 39513722Z | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION 25 STORY FACADE AND BALCONY REPAIR ALTERATION CLOSED SITE OBSERVED SWS IN PLACE AT EXP 1. UPON ... | $1,280 | $0 | May 11, 2023 |
| May 26, 2022 | 39062924R | RESOLVE | CLASS - 1 | CAR SAFETY/INOPERATIVE/REPAIR. | $1,250 | $0 | Jul 14, 2022 |
| Nov 1, 2021 | 37022522P | ACTIVE | CLASS - 2 | 27-929.1 FAILURE TO COMPLETE INSTALLATION OF FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE FINAL SPRINKLER REPORT PREP... | $3,125 | $0 | Mar 17, 2022 |
| Dec 10, 2020 | 37020560R | ACTIVE | CLASS - 2 | SEC. 27-929.1 FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OFAUTOMATIC SPRINKLERS & FILE A FINAL SPRINKLER R... | $1,280 | $0 | Aug 5, 2021 |
| Nov 1, 2018 | 35344892L | RESOLVE | CLASS - 2 | WORKING W/O SIDEWLAK SHED PERMIT PERMIT EXPIRED 10/16/18. AT TIME OF INSPECTION 11/1/18. RMDY: RENEW PERMIT AS PER 1R... | $0 | $0 | Dec 27, 2018 |
| Aug 4, 2017 | 35253998X | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING EXTERIOR WALL/FACADE AND APPURTENANCES.NOTE:EAST ELEVATION EXPOSURE 1:BROKEN CRACKED AND... | $500 | $0 | Sep 21, 2017 |
| May 16, 2017 | 38255093J | RESOLVE | CLASS - 1 | CU-5M7,CU-34X10,CU-17M11,68B7,68B7,59BB15,17M7,40Q3,29Q3,61T7,41I10,39O2. CU-5M7-DOOR ZONE RESTRICTOR. THIS IS A SAFE... | $1,000 | $0 | Jul 6, 2017 |
| Jun 28, 2016 | 35174577M | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BLDG GENERAL NOTES:A/C UNITS MISSING BRACKETS EAST ELEV.EXP#1 HORIZONTAL/VERTICLE CRACKS... | $500 | $0 | Aug 18, 2016 |
| Nov 2, 2015 | 36023546H | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS:36026754X.PERIODIC INSP OF EXTERIOR WA... | $2,000 | $0 | May 12, 2016 |
| Oct 16, 2015 | 35133753L | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BLDG EAST ELEV EXP1(ALL ELEV)A/C UNITS NOT INSTALLED AS PER CODE-SCREEN 7FL NOT BC CODE ... | $500 | $0 | Dec 24, 2015 |
| Dec 12, 2014 | 36026754X | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE CYCLE 7 TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS: PERIODIC INSPECTION OF EXT... | $800 | $0 | Apr 9, 2015 |
| Apr 19, 2012 | 34941772X | RESOLVE | CLASS - 1 | WORK WITHOUT A PERMIT NOTED:REPAIRING BALCONY REMOVING CONCRETE AT UNDER SIDE OF THE 23RD FLR WHILE DOING SO CHANGES ... | $1,600 | $0 | Jun 8, 2012 |
| Apr 19, 2012 | 34941773H | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCT OPERATIONS CONCRETE FROM BALCONY HAS FALLEN UNTO AD... | $2,400 | $0 | Jun 7, 2012 |
| Nov 2, 2011 | 38218838M | RESOLVE | CLASS - 2 | 97X10,16B. 97-RETURN TO SERVICE SO A FULL INSPECTION CAN BE MADE BY THE DEPARTMENT. 16- LARGE GAPS ON HOISTWAY DOORS ... | $500 | $0 | Jan 26, 2012 |
| Nov 2, 2011 | 38218837K | RESOLVE | CLASS - 2 | 59B10,69#07,42B10,42X10,12X10,08V01,100R#,10H11,71X10,32J01,78B10. 59-CLEAN TUBE BRAKE ASSEMBLY. 69-PROVIDE CORRECT Y... | $0 | $0 | Jan 26, 2012 |
| Nov 2, 2011 | 38218839Y | RESOLVE | CLASS - 2 | 59B10,42B10,69B01,42X10,42B11,60X10,37O02,37X10,45D06,42D06,21M07,52B02,39M07,11X10,16M02,11X10,16M08,79O02,79B01,79B... | $0 | $0 | Jan 26, 2012 |
| Feb 23, 2011 | 38214947N | RESOLVE | CLASS - 2 | 29E01 32E10 40O02 42D06 32E-RUBBING SCRAPING OF RAILS REPAIR 29E-DOOR OPERATOR CLUTCH SCRAPING FASCIAS 42D-SECURE CON... | $0 | $0 | Apr 14, 2011 |
| Feb 23, 2011 | 38214946L | RESOLVE | CLASS - 2 | 29E01 42D06 40O02 45M07 29E-DOOR OPERATOR CLUTCH SCRAPING FASCIAS & ROLLERS INTERLOCKS ADJUST 42D-SECURE CONTROLLER C... | $0 | $0 | Apr 14, 2011 |
| Feb 23, 2011 | 38214945J | RESOLVE | CLASS - 2 | 29E01 40O02 42D06 45M7 29E-DOOR OPERATOR CLUTCH SCRAPING FASCIAS &ROLLERS IN TEN LOCKS ADJUST 42D-SECURE CONTROLLER C... | $0 | $0 | Apr 14, 2011 |
| Dec 8, 2010 | 38214191M | RESOLVE | CLASS - 2 | 42H11,68M07,61M07,41I10,45M07. 42H11- REPLACE WORN CARBON CONTACTS ON CONTROLLER. 68M07- PROVIDE MISSING MAINTENANCE ... | $250 | $0 | Jan 27, 2011 |
| Dec 17, 2004 | 38150484X | RESOLVE | Non-Hazardous | 41M07/60M07/83M07/83M07/41G07/38O02/11L07.(41-M-07)PROVIDE ALL COVERS CONTROLLER.(60-M-07)COMPANY STICKER.(83-M-07)NU... | $0 | $0 | Feb 3, 2005 |
| Dec 17, 2004 | 38150481K | RESOLVE | Non-Hazardous | 10H10/38O02/21M07/66Z09/66O02/69J10/16L10/21M07/17H10/72B07/49L10/60M07/44H10 (10-H-10) REPAIR WORN CAR DOOR GIBS. (3... | $0 | $0 | Feb 3, 2005 |
| Dec 17, 2004 | 38150485H | RESOLVE | Non-Hazardous | 41M07/60M07/83M07/41G07/38O02/10H10/05J01/11L07.(41-M-07)PROVIDE ALL COVERS CONTROLLER.(60-M-07)COMPANY STICKER.(83-M... | $0 | $0 | Feb 3, 2005 |
| Dec 17, 2004 | 38150482M | RESOLVE | Non-Hazardous | 60M07/38O02/66O02/34D06 (60-M-07) PROVIDE COMPANY STICKER MAIN LINE SWITCH. (38-O-02) CLEAN CAR TOP (66-O-02). (34-D-... | $0 | $0 | Feb 3, 2005 |
| Dec 17, 2004 | 38150483Y | RESOLVE | Non-Hazardous | 41M07/60M07/83M07/41G07/38L10/05H01/10H10/11L07.(41-M-07)PROVIDE ALL COVERS.(60-M-07)COMPANY STICKER.(83-M-07) NUMBER... | $0 | $0 | Feb 3, 2005 |
| Feb 2, 2004 | 38144915H | RESOLVE | Non-Hazardous | 17J01,25D06,36B07,44Q13,49E09,60G09,66Z09,84##.17-ADJUST WHERE NECESSARY 25-SECURE 36-PROVIDE LIGHTING IN SECONARDY 4... | $0 | $0 | Apr 1, 2004 |
| Aug 14, 2003 | 38140806K | RESOLVE | Non-Hazardous | 44,B,#,59,D,06 44B GOVERNOR NOISY LUBE GREASE 59D SECURE LIGHT SWITCH FOR MACHINE ROOM | $0 | $0 | Oct 2, 2003 |
| Feb 2, 2003 | 38144906X | RESOLVE | Non-Hazardous | 17J01,25D06,36B07,44Q13,49E09,60G09,66Z09,84##. 17-ADJUST WHERE NECESSARY 25-SECURE 36-PROVIDE LIGHTING IN SECONDARY ... | $0 | $0 | Mar 18, 2004 |
| Dec 5, 2002 | 34378364R | RESOLVE | Non-Hazardous | ILELGAL USE IN A MANUFACTURING DISTRICT CUT OUT STORE APPROX 3' NORTH OF MAIN ENTRANCE USING SIDEWALK IN FRONT OF STO... | $0 | $0 | Apr 3, 2003 |
| Aug 13, 2002 | 38124062R | RESOLVE | Non-Hazardous | 73##. SEC 27-1006 FAILURE TO RESORT AN ACCIDENT PROMPTLY ACCIDENT OCCURRED 7.31.02 ACCIDENT REPORTED 8/12/02 | $0 | $0 | Oct 3, 2002 |
| Aug 8, 2002 | 38124710X | RESOLVE | Hazardous | 05I11-22W06-06I11-15I11-02X11. 05-I-11 UNABLE TO CLOSE GATE IN ORDER TO MAKE GATE GWITCH 22-W-06 OPERATING EQUIPTMENT... | $500 | $0 | Sep 26, 2002 |
| Jul 29, 2002 | 38124701Y | RESOLVE | Non-Hazardous | 44L09-74O02-40H11-50O02-37R09-74O02-46B10. 44-L-09 REMOVE MOISE FROM PERERATOR 74-O-02 CLEAN TOP OF CAR 40-H-11 GOVEN... | $440 | $0 | Oct 3, 2002 |
| Jul 29, 2002 | 38123950K | RESOLVE | Non-Hazardous | 74O02-*74X11-40O02-50O02. 74-O-02 SECONDARY SHEAVE & ROOM DIRTY PROPERTY CLEAN SHVET ROOM 74-X-11 REPAIR SECONDARY LI... | $440 | $0 | Oct 3, 2002 |
| Jun 1, 2001 | 38116286X | RESOLVE | Non-Hazardous | 05L11 11Q03 50F11 40M07 40O02 40M07 74O07 14B07 15J01 (05-L-11) REPAIR GATE (11Q03) PROVIDE GUARD (50F-11) REPAIR LOS... | $180 | $0 | Jul 19, 2001 |
| Jun 1, 2001 | 38116285Y | RESOLVE | Non-Hazardous | 44L09 50M07 40M07 40O02 74X11 05X11 33M03 74O02 (44-L-09) REMOVE NOISE GENENATOR (50-M07) PROVIDE MISSING CABLE GUARD... | $180 | $0 | Jul 19, 2001 |
| Feb 12, 2001 | 38111217J | RESOLVE | Non-Hazardous | 50O02,74O02,74X11,46M07,47M07,74O02. 74O02 SECODARY SHEABE DIRTY CLEAN SHEABE & ROOM.74X11 REPAIR DECONDRAY LIGHTS. 4... | $0 | $0 | Mar 29, 2001 |
| Feb 12, 2001 | 38111216H | RESOLVE | Non-Hazardous | 50O02,35O02,74O02,74X19,73F11,22W06,74X12,25B12,74B12,74B09. 74O02 SECONDRARY SHEAVE & ROOM DIRTY(SECONDRY LIGHTS REP... | $0 | $0 | Mar 29, 2001 |
| Nov 18, 1999 | 38092407J | RESOLVE | Non-Hazardous | 44M07,57O02,03O02,64O02. #44-M-0- PUT COVER ON CONNECTIONS #03-O-02- CLEAN CAR TOP | $0 | $0 | Jan 6, 2000 |
| Nov 18, 1999 | 38092403M | RESOLVE | Non-Hazardous | 57O02,03O02,4O02. #03-O-02 CLEAN CAR TOP | $0 | $0 | Jan 6, 2000 |
| Nov 18, 1999 | 38092404Y | RESOLVE | Non-Hazardous | 21M07,36T07,10M07,57O02,03O02,64O02. #21-M-07 PROVIDE SCREWS IN PIS # 10-M-07- PROVIDE SCREWS # 03-O-02 CLEAN CAR TOP | $0 | $0 | Jan 6, 2000 |
| Nov 18, 1999 | 38092405X | RESOLVE | Non-Hazardous | 57O02,03O02,48H15,55M07,64O02. #03-O-02 CLEAN CARTOP | $0 | $0 | Jan 6, 2000 |
| Nov 18, 1999 | 38092406H | RESOLVE | Non-Hazardous | 50O02,48H15,57O02,03O02,64O02. #03-O-02 CLEAN CAR TOP | $0 | $0 | Jan 6, 2000 |
| Aug 11, 1997 | 38062803Y | RESOLVE | Non-Hazardous | 75U35OXO26M47N 75-5 YEAR TEST 35-CLEAN SECONDARY 53-PROVIDE LIGHT IN MOTOR RM & SECONDARY X-CLEAN TOP OF CAR 26-COVER... | $0 | $0 | Oct 2, 1997 |
| Aug 11, 1997 | 38062802M | RESOLVE | Hazardous | 46R75VXM57Z57O 46-HOIST CABLES TO LONG HITTING SPRING PIT 75-5 YEAR TEST X-VO & DOWN LIGHT COVER MISSING 57-WATER IN ... | $0 | $0 | Nov 20, 1997 |
| Aug 11, 1997 | 38062806J | RESOLVE | Non-Hazardous | 75U46M57O 75-5 YEAR TEST 46-CABLE GUARDS IN SECONDARY 57-CLEAN PIT. | $0 | $0 | Oct 2, 1997 |
| Aug 11, 1997 | 38062805H | RESOLVE | Non-Hazardous | 75U35O35M25M46M37M57M 75-5 YEAR TEST 35-CLEAN SECONDARY 35-PROVIDE LIGHTS SECONDARY 25-REPLACE DOOR OPP, COVER 46-HOI... | $0 | $0 | Oct 2, 1997 |
| Aug 11, 1997 | 38062804X | RESOLVE | Non-Hazardous | 75U35OX037M57M 75- 5 YEAR TEST 35- PROVIDE LIGHTS IN MOTOR RM OF SECONDARY X-CLEAN TOP OF CAR 37-COVER ON CONTROLLER ... | $0 | $0 | Oct 2, 1997 |
| Feb 10, 1992 | 38021816M | RESOLVE | Non-Hazardous | 15L,15L,15L,1I,16L,47#,57O,30O,74#,74AL, (47) SHORTEN THE GOVERNOR CABLE (74) RENOVE COMPLETELY THE BY PASS KEY SWITC... | $185 | $0 | Mar 26, 1992 |