ECB violations
333 West 38 Street, Manhattan • Block 00762 • Lot 0016
25 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Feb 21, 2019 | 35369436Z | RESOLVE | CLASS - 1 | BC3310.8.4.1/SITE SAFETY MANAGER LOG BOOK INSPECTIONS.AT TIME OF INSPECTION OF A NEW 22 STORY BUILDING TOPPED OFF I O... | $0 | $0 | Apr 18, 2019 |
| Feb 21, 2019 | 35369434P | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN/DISPLAY ON SITE DOCUMENTS REQUIRED BY CHAPTER 33.AT TIME OF INSPECTION AT A TWENTY TWO(22)STORY N... | $312 | $0 | Jun 20, 2019 |
| Feb 21, 2019 | 35369435R | RESOLVE | CLASS - 2 | RESPONSIBILITY OF OWNER OF TALL BUILDING-NEIGHBORING BUILDINGCHIMNEY NOT EXTENDED.AT THE TIME OF MY INSPECTION OF A N... | $620 | $0 | Apr 18, 2019 |
| May 9, 2018 | 35331129P | RESOLVE | CLASS - 1 | BC3301.4.CONCRETE EMBEDDED SAFETY STRAPS(LOGS/INSPECTION)AT TIME OF INSPECTION I OBSERVED CONCRETE EMBEDDED STRAPS TH... | $625 | $0 | Sep 6, 2018 |
| Mar 26, 2018 | 35318285K | RESOLVE | CLASS - 2 | 3301.2.HOLES NOT COVERED.@ TIME OF INSPECTION OF NEW 22 STORY BUILDINGON ACTIVE JOBSITE.BUILDING TOPPED OFF WITH CONS... | $0 | $0 | May 10, 2018 |
| Mar 26, 2018 | 35318284Z | RESOLVE | CLASS - 2 | 3301.1.2.FIRE CODE(EXIT SIGNS)@ TIME OF INSPECTION OF NEW 22 STORY BUILDING.BUILDING TOPPED OFF,WITH ACTIVE JOBSITE C... | $0 | $0 | May 10, 2018 |
| Feb 22, 2018 | 35317711J | RESOLVE | CLASS - 2 | 3308.6 HORIZONTAL NETTING-AT TIME OF INSPECTION ON A ACTIVE JOBSITE OFA 22 STORY BUILDING,OBSERVED HORIZONTAL NETTING... | $400 | $0 | Apr 12, 2018 |
| Nov 13, 2017 | 35286579M | RESOLVE | CLASS - 1 | SEC: 3301.1.1. RESPONSIBILITY FOR SAFETY: NO CAZ. NOTE: 22 STORY BLDG ERECTED TO THE 15 FLR. @ THE 6 FLR SET BACK @ E... | $1,600 | $0 | Mar 22, 2018 |
| Nov 13, 2017 | 35286577Z | RESOLVE | CLASS - 1 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS &/OR AMENDMENTS. NOTE: OBSERVED 22 STORY BLDG ERECTED TO THE... | $0 | $0 | Dec 28, 2017 |
| Nov 13, 2017 | 35286576R | RESOLVE | CLASS - 1 | FAIL TO PERFORM HYDROSTATIC PRESSURE TEST: STAND PIPE. NOTE: 22 STORY BLDG ERECTED TO THE 15 FLR THE STAND PIPE ON SI... | $2,400 | $0 | Dec 28, 2017 |
| Nov 13, 2017 | 35286578K | RESOLVE | CLASS - 1 | SEC: BC 3309.1. FAILURE TO ADEQUATELY PROTECT ADJOINING PROPERTIES DIVING CONSTRUCTION OPERATIONS. NOTE: 22 STORY BLD... | $400 | $0 | Mar 22, 2018 |
| Sep 21, 2017 | 35288814M | RESOLVE | CLASS - 2 | FAILURE TO SAFEGUARD PEOPLE/PROPERTY:INADEQUATE VENTING NOTE:22 STORY BUILDING ERECTED TO THE 6TH FL FORMING 7TH FLOO... | $10,000 | $0 | Nov 9, 2017 |
| Sep 21, 2017 | 35288815Y | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN/DISPLAY ON SITE DOES REQUIRED BY CHAPTER 33.OBSERVED ACTIVE SITE ERECTED TO THE 6TH FL-AT EXPO # ... | $1,250 | -$1,250 | Nov 9, 2017 |
| Sep 21, 2017 | 35288812Z | RESOLVE | CLASS - 1 | 3301.1.1RESPONSIBILITY FOR SAFETY:INADEQUATE EGRESS NOTE:OBSERVED 22 STORY BUILDING ERECTED TO THE 7 FLOOR (FRAME WOR... | $4,000 | $0 | Nov 9, 2017 |
| Sep 7, 2017 | 35239101L | RESOLVE | CLASS - 1 | SEC. 3303.2.4 SANITARY FACILITY. AT TIME OF INSPECTION ON ACTIVE CONSTRUCTION SITE I OBSERVED ONLY 1 PORTABLE SANITAR... | $1,600 | $0 | Oct 26, 2017 |
| Sep 7, 2017 | 35265698M | RESOLVE | CLASS - 1 | SEC. 3310.3 FAILURE TO COMPLY W/SSP AT TIME OF INSPECTION I OBSERVED THAT CONSTRUCTION ACTIVITYS ON STREET AT EXP#1 W... | $400 | $0 | Oct 26, 2017 |
| Sep 7, 2017 | 35265699Y | RESOLVE | CLASS - 1 | SEC. 3309.1 FAILURE TO ADEQUATELY PROTECT ADJ PROPERTY AT TIME OF INSPECTION,OBSERVED THAT LOT LINE WINDOWS WERE NOT ... | $1,600 | $0 | Oct 26, 2017 |
| Sep 5, 2017 | 35246391Y | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE APPROVED/ACCEPTED CONSTRUCTION DOCUMENTS AT JOB SITE AT TIME OF INSPECTION. NB JOB #121187429. AT ... | $0 | $0 | Oct 26, 2017 |
| Apr 25, 2017 | 35246950L | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTIONOPERATIONS.AT TIME OF INSPECTION OBSERVED CRACK... | $2,400 | $0 | Feb 15, 2018 |
| Apr 20, 2017 | 35239849L | RESOLVE | CLASS - 1 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND OR AMENDMENTS.NOTE:SITE IN FOUNDATION EXCAVATION PHASE-A... | $1,000 | $0 | Feb 15, 2018 |
| Apr 20, 2017 | 35238225Z | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN/DISPLAY ON SITE DOCUMENTS REQUIRED BY CHAPTER 33.NOTE:SITE WITHIN EXCAVATION/FOUNDATION PHASE.DOB... | $500 | $0 | Nov 2, 2017 |
| Apr 20, 2017 | 35238226K | RESOLVE | CLASS - 2 | BC3301.3/SITE SAFETY MANAGERS:TO BE DESIGNATED.NOTE;22 STORY BUILDING WITH FOUNDATION EXCAVATION PHASE DOB BIS-STATES... | $800 | $0 | Feb 15, 2018 |
| Aug 24, 2016 | 35162975J | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE APPROVED/ACCEPTED PLANS AT JOB SITE AT TIME OF INSPECTION. NOTE: AT THE TIME OF MY INSPECTION OF A... | $250 | $0 | Oct 13, 2016 |
| Aug 24, 2016 | 35162974H | RESOLVE | CLASS - 1 | SEC. 3309.4.4 MONITORING. NOTE: AT THE TIME OF MY INSPECTION OF A 22 STY BLDG AT EXCAVATION PHASE,CONSTRUCTION WORK I... | $1,600 | $0 | Oct 13, 2016 |
| Jan 19, 2016 | 35166500Y | RESOLVE | CLASS - 1 | BC3301.4. INSPECTION NOTE: AT TIME OF MY INSPECTION OF COMPLAINT #1414799 WHERE IT WAS REPORTED THAT FIRE TO COMPRESS... | $1,630 | $0 | Mar 10, 2016 |