ECB violations

318-326 West 39 Street, Manhattan • Block 00762 • Lot 0050

64 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Jun 17, 2024 37028752H ACTIVE CLASS - 2 A. C. 27-929.1, FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL SPRINK... $3,125 $0 Dec 12, 2024
Feb 28, 2023 37025339K ACTIVE CLASS - 2 27-929.1 FAILURE TO COMPLETE INSTALLATION OF FULL SYSTEM OF AUTOMATIC SPRINKLERS & FILE FINAL SPRINKLER REPORT PREPAR... $3,125 $0 Aug 10, 2023
Mar 30, 2021 37020779L ACTIVE CLASS - 2 27-929.1 FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL SPRINKLER REP... $3,125 $0 Oct 21, 2021
Sep 29, 2020 37020267H ACTIVE CLASS - 2 SEC. 27-929.1 FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OFAUTOMATIC SPRINKLERS & FILE A FINAL SPRINKLER R... $1,280 $0 Dec 31, 2020
Jul 13, 2017 38255299P RESOLVE CLASS - 2 59V15,68M7,68M7,60Q7. NO TAG STATING DATE OF ANNUAL BRAKE MAINTENANCETHERE IS NO MAINTENANCE IN MACHINE ROOM, NO STIC... $250 $0 Aug 31, 2017
Jun 20, 2017 37003293R RESOLVE CLASS - 2 FAILURE TO FILE ANNUAL CERTIFICATION THAT COOLING TOWER 1000004349 HASBEEN INSPECTED,TESTED,AND DISINFECTED,AND THAT ... $1,000 $0 Dec 14, 2017
Sep 14, 2013 38228244Y RESOLVE CLASS - 2 03L10 - EXIT COVER IS WRONG SIZE REPLACE & TEST. $0 $0 Oct 31, 2013
Jul 20, 2011 38217119L RESOLVE CLASS - 2 56Y02 42G07 39Q03 67B01 77X10 K3 40M07 K3. 56-CLEAN OIL FROM BED PLATE. 42-PROVIDE PROPER FUSES FOR CONTROLER. 39-INS... $0 $0 Sep 8, 2011
Jan 26, 2011 38214858L RESOLVE CLASS - 2 69M07 56Y10 69M-PROVIDE CODE DATA PLATE 56Y-REPAIR OIL LEAK $0 $0 Mar 17, 2011
Jan 26, 2011 38214857J RESOLVE CLASS - 2 69M07 56Y10 69M-PROVIDE CODE DATA PLATE 56Y10-REPAIR OIL LEAK $0 $0 Mar 17, 2011
Oct 6, 2010 34872648M RESOLVE CLASS - 1 FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS.NOTED:OBSERVED CONTRACTOR ROSS WINDOW... $2,400 $0 Mar 3, 2011
Oct 6, 2010 34872647K RESOLVE CLASS - 2 FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS NOTED:UPON INSP OBSERVED CONSTRUCTION & HOUSEHOLD ... $0 $0 Dec 2, 2010
Apr 21, 2009 38202875P RESOLVE CLASS - 2 71X10.71Q3.77X10.67B1.17H11.40R9 39 CAR TOP LIGHT 77 UNDER CAR LIGHT 69 ADJUST VOLUME OF EMERG. PH. 17 REPLACE LOBBY ... $0 $0 Jun 11, 2009
Mar 25, 2009 34764675J RESOLVE CLASS - 1 UNLAWFULLY CONTINUEED WORK WHILE ON NOTICE OF A STOP WORK ORDER. NOTED: CONTINUED WORK ON OUTRIGGER SUSPENDED SCAFFOL... $0 $0 Aug 6, 2009
Jan 26, 2009 34744609N RESOLVE CLASS - 1 WORK W/O PERMIT. UPON PHYSICAL INSPECTION FOUND SPRINKLER HEADS BEING VIOLATED/REMOVED ON 5FL W/O PERMIT. REMEDY:OBTA... $1,600 $0 Jun 18, 2009
Nov 7, 2008 36000656R RESOLVE CLASS - 2 FAILURE TO FILE AN AMENDED 6TH ROUND REPORT ACCEPTABLE TO THIS DEPARTMENT INDICATING CORRECTION OF UNSAFE CONDITIONS ... $800 $0 Mar 27, 2009
Oct 16, 2008 34709741R RESOLVE CLASS - 1 LICENSED RIGGER FAILED TO ENSURE SCAFFOLD WORKER MET MINIMUM REQUIREMENTS. NOTED: WORKERS ON SUSPENDED SCAFFOLD. W/O ... $0 $0 Apr 17, 2009
Oct 16, 2008 34709742Z RESOLVE CLASS - 1 NO RECORD OF DAILY INSPECTION OF SUSPENDED SCAFFOLD PERFORMED BY AUTHORIZED PERSON AT SITE. NOTED: NO DAILY INSP LOG ... $0 $0 Apr 17, 2009
Oct 16, 2008 34709744M RESOLVE CLASS - 2 FAILURE TO PROVIDE APPROVED/ACCEPTED PLANS AT JOB SITE AT TIME OF INSPECTION. NOTED: NO DRAWING FOR OUTRIGGER BEAMS O... $0 $0 Apr 17, 2009
Aug 1, 2008 34684648Y RESOLVE CLASS - 1 OPERATIONS OF HOISTING EQUIPMENT IN AN UNSAFE MANNER. USING PULLEY SYSTEM TO LOWER DEBRIS FROM ROOF LEVEL PIECE OF 2'... $0 $0 Aug 20, 2009
Jul 9, 2008 34684566K RESOLVE CLASS - 2 FAILED TO NOTIFY THE DEPARTMENT/OBTAIN PRIOR TO THE USE/INSTALLATION OF 'C' HOOKS AND OUTRIGGER BEAMS IN CONNECTION W... $800 $0 May 7, 2009
Jul 9, 2008 34684569X RESOLVE CLASS - 1 ERECTED MAINTAINED A SCAFFOLD OVER 40FT W/O PERMIT. REMEDY: OBTAIN A PERMIT. $1,200 $0 May 7, 2009
Jul 9, 2008 34684570N RESOLVE CLASS - 2 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS SCAFFOLD IS NOT SET-UP ACCORDING TO APPROVED CD-S. REMEDY: A... $500 $0 May 7, 2009
Jun 16, 2008 38183049M RESOLVE Non-Hazardous 41G07.02X10.01B10.06B01.84R09.84M09. 41 PROVIDE PROPER FUSES IN CONTROLLER 02 EMG.PHONE INOPERATIVE 01 STOP BUTTON DO... $350 $0 Aug 7, 2008
Mar 28, 2008 34684139X RESOLVE Non-Hazardous FAILURE TO FILE AN AMENDED 6TH ROUND REPORT ACCEPTABLE TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRI... $700 $0 Jun 26, 2008
Dec 29, 2007 32055383N RESOLVE Non-Hazardous 50A,B. FULTON VT BOILER,15HP,NB58421,GAS,1989.50A-INADEQUATE STRUCTURESUPPORT OF THE BOILER LOADED FLUE PIPE SYSTEM.I... $0 $0 Feb 21, 2008
Dec 29, 2007 32055384P RESOLVE Non-Hazardous 50A,B.FULTON VT BOILER,15HP,NB 58421,GAS 1989.50A-INADEQUATE STRUCTURESUPPORT OF THE FLUE PIPE SYSTEM.INSTALL A HEAVY... $0 $0 Feb 21, 2008
Dec 29, 2007 32055381J RESOLVE Non-Hazardous 18A,50A,B,C.FULTON VT BOILER,10HP,NB65022,GAS,1992.18A-SCALE ACCUMUALATION AT HANDHOLE OPENING REMOVE SCALE CLEAN & R... $180 $0 Feb 21, 2008
Dec 29, 2007 32055382L RESOLVE Non-Hazardous 18A,B,50A,B,C,D.FULTON VT BOILER,15HP,NB 33767,GAS 1991.18A,B-CORROSION,SCALE ACCUMULATION & EVIDENCE OF LEAKAGE AT U... $180 $0 Feb 21, 2008
Jun 1, 2006 38159554N RESOLVE Non-Hazardous 83X10. REPAIR ELEVATOR & RETURN TO SERVICE SO PROPER INSPECTION CAN BE MADE $0 $0 Jul 20, 2006
May 23, 2006 32049981M RESOLVE Non-Hazardous 34B $2,500 $0 Sep 28, 2006
May 23, 2006 32049983X RESOLVE Non-Hazardous 1989 FULTON NAIL BD.# 58421 $5,000 $0 Dec 14, 2006
May 23, 2006 32049980K RESOLVE Hazardous 51,50,48A,48B/1991 FULTON NB 33767-FIRE HAZARDOUS CONDITION/51-BOTTOM LEFT HANDHOLE AREA CASEING HAS HOLES ALL AROUND... $500 $0 Jul 27, 2006
Jul 19, 2004 32045332Y RESOLVE Non-Hazardous 48AB/50A 50B/50C FULTON V.T. BOILER, 10HP, NB 65022, GAS 1992 50A NO STRUCTURAL SUPPORTS ON THE FLUE PIPE SYSTEM. INS... $0 $0 Sep 2, 2004
Jul 19, 2004 32045338P RESOLVE Non-Hazardous 36/50A 50B/50C 50D/50E FULTON V.T. BOILER, NB 58421, 15HP, GAS, 1989 50A) NO HANGER ON THE FLUE PIPE. 50B) NO DISCHAR... $180 $0 Sep 2, 2004
Jul 19, 2004 32045337N RESOLVE Non-Hazardous 50A/50B 50C/50D 44C FULTON V.T. BOILER, 10HP, NB65379, GAS 1992 50A NOSTRUCTURAL SUPPORTS ON THE FLUE PIPE SYSTEM. IN... $0 $0 Sep 2, 2004
Jul 19, 2004 32045334H RESOLVE Non-Hazardous 50A/50B 50C FULTON V.T. BOILER, 15HP NB 33767, GAS, 1991 50A) NO STRUCTURAL SUPPORTS ON THE FLUE PIPE SYSTEM. INSTALL... $180 $0 Nov 18, 2004
Jul 19, 2004 32045336L RESOLVE Non-Hazardous 50A/50B FULTON V.T. BOILER, 15HP, NB 67688, GAS, 1993 50A IMPROPER ARRANGEMENT OF BLOWDOWN VALVES ON THE BOILER. INST... $0 $0 Sep 2, 2004
Jul 19, 2004 32045335J RESOLVE Non-Hazardous 50A/50B FULTON V.T. BOILER 15HP, NB 76526, GAS 1996 50A FLUE PIPE SUPPORTED BY LOOSE BAND IRON. REPLACE WITH A HEAVY-... $0 $0 Sep 2, 2004
Mar 14, 2003 34384718X RESOLVE Non-Hazardous FAILURE TO FILE AN AMENDED ROUND FIVE REPORT ACCEPTABLE TO THIS DEPAR TMENT PURSUANT TO RULE R.C.N.Y. 32-03B(5), INDI... $1,000 $0 Jun 19, 2003
Jan 13, 2003 34379889Y RESOLVE Hazardous FAILURE TO FILE AN AMENDED ROUND FIVE REPORT ACCEPTABLE TO THIS DEPARTMENT PURSUANT TO RULE R.C.N.Y. 32-03B(5), INDIC... $400 $0 Apr 17, 2003
Nov 8, 2002 34335789M RESOLVE Hazardous FAILURE TO FILE AN AMENDED ROUND FIVE REPORT ACCEPTABLE TO THIS DEPARTMENT PURSUANT TO RULE R.C.N.Y. 32-03B(5), INDIC... $400 $0 Jan 16, 2003
Apr 18, 2002 34291253M RESOLVE Hazardous FAILURE TO MAINTAIN EXTERIOR OF BUILDING. DAMAGED TERRA COTTA TILE ON THE NORTH ELEV. 11TH FLOOR. BRICK BUIGING ON TH... $800 -$800 Jun 6, 2002
Feb 4, 2002 38119685R RESOLVE Non-Hazardous 40O02,47OO2,50O02,57O02,74O02,46O02,59O02,46T13,37T07,18Q03 - 74-O-02 CLEAN CAR TCP, 46-T-13 RESHACKLE HEIST CABLES, ... $0 $0 Mar 21, 2002
Nov 14, 2001 38119614J RESOLVE Non-Hazardous 57O02/ 73O02/ 30O02/ 74I04/ 74I04 LOBBY WALL ABOVE HALL BUTTONS HUGE HOLE REPAIR & PATCH HOLE $0 $0 Jan 3, 2002
Oct 10, 2001 38118923Z RESOLVE Non-Hazardous 46H13-LAST DATE ON TOP OF CAR IS 1989 OVERHEAD DRUM MACHINES HAVE TO BE RESHACLED EVERY YEAR ON TOP OF CAR DROM COUNT... $0 $0 Nov 29, 2001
Sep 7, 2001 38118656N RESOLVE Hazardous CEASE USE 05N09-22D06-57P07-73O02 05-GATE SWITCH INOPERABLE 22-SECURE 57-PROVIDE 73-CLEAN ENTIRE DEVICE $500 $0 Oct 25, 2001
Aug 1, 2001 38118112P RESOLVE Hazardous OPERATOR WAS OPERATING DEVICE WITH JUMP GATE SWITCH CEASE USE CALL DEPT OF BUILDING BEFORE RETURNING BACK TO SERVICE ... $2,500 $0 Nov 1, 2001
Nov 10, 1999 34227901P RESOLVE Hazardous FAILURE TO MAINTAIN BUILDING(HAZARDOUS) NOTED: ALL FIRE DOORS IN BUILDING ARE NOT UP TO CODE. MOST MISSING PANIC BARS... $800 $0 Jul 24, 2003
Oct 21, 1998 32016523Y RESOLVE Non-Hazardous 18A,18B,49. 18A-HANDHOLES CORRODED. 18B-HANDHOLES LEAKING. 49-LOW WATER SAFETY RELAY SWITCH NOT CONNECTED. $180 $0 Dec 10, 1998