Skip to content

ECB violations

209 West 18 Street, Manhattan • Block 00768 • Lot 0030

26 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Feb 29, 2024 35680609J RESOLVE CLASS - 1 WORK WITHOUT A PERMIT. AT THE TIME OF INSPECTION I OBSERVED CONSTRUCTION WORK IN PROGRESS WITH APPROXIMATELY(10-WORKE... $2,500 $0 Jul 24, 2025
Feb 29, 2024 35680606Y ACTIVE CLASS - 2 FAILURE TO SAFEGUARD. OBSERVED CONSTRUCTION WORK IN PROGRESS AT THE TIME OF INSPECTION. CONSTRUCTION WORKER WAS FIXIN... $5,000 $0 Jan 2, 2025
Feb 29, 2024 35680607X RESOLVE CLASS - 1 DEMOLITION WORK WITHOUT A PERMIT. OBSERVED CONSTRUCTION WORK IN PROGRESS BY CONSTRUCTION WORKERS THROUGHOUT THE ENTIR... $0 $0 Jul 24, 2025
Jan 22, 2024 35671247R RESOLVE CLASS - 2 PERMIT NOT POSTED.ECB VIO ISSUED FOR PERMITS NOT POSTED.ATOL OBSERVED PIPE SCAFFOLD INSTALLED AT EXP 1 PERMIT NOT POS... $0 $0 May 2, 2024
Jan 22, 2024 35671248Z RESOLVE CLASS - 2 TEMPORARY CONSTRUCTION EQUIPMENT ONSITE-EXPIRED PERMIT ECB VIO ISSUED FOR CONSTRUCTION FENCE EXPIRED PERMIT ATOI OBSE... $625 $0 Apr 25, 2024
Apr 27, 2023 39515939Z RESOLVE CLASS - 2 ACTIVE PERMIT 122365485, CLOSED SITE NO ONGOING CONSTRUCTION ACTIVITY UPON RESEARCH ON BIS AND DOB NOW WAS NOTED FENC... $3,125 $3,125 Jul 6, 2023
Apr 27, 2023 39515940X ACTIVE CLASS - 2 ACTIVE ALT PERMIT 122365485 ,CLOSED SITE UPON VISUAL INSPECTION WAS NOTED PASSAGEWAY BELOW SIDEWALK SHED NOT ILLUMINA... $10,000 $10,000 Jul 6, 2023
Nov 1, 2022 39508586R RESOLVE CLASS - 2 UPON REQUEST, GC UNABLE TO PROVIDE A LOADS-IMPOSED LETTER FOR SIDEWALK SHED OBSERVED AT EXPOSURE 1 USED TO SUPPORT SU... $0 $0 Dec 22, 2022
Feb 24, 2021 35544072M RESOLVE CLASS - 2 TEMPORARY CONSTRUCTION EQUIPMENT ON SITE EXPIRED PERMIT. NOTE: AT THE TIME OF MY INSPECTION OF AN 5 STY BLDG W/ACTIVE... $0 $0 May 13, 2021
Oct 27, 2020 35539784Y RESOLVE CLASS - 1 CONSTRUCTION SUPERINTENDENT FAILED TO PERFORM DUTIES:AT TIME OF INSPECTION AT AN ACTIVE JOBSITE ALT-2 FOR INTERIOR RE... $0 $0 Jan 14, 2021
Oct 27, 2020 35539783M RESOLVE CLASS - 1 FAILURE TO DESIGNATE AND/OR HAVE A CONSTRUCTION SUPERINTENDENT PRESENTAT SITE AS REQUIRED:AT TIME OF INSPECTION AT AN... $625 $0 Jan 14, 2021
Feb 27, 2020 35470318Y RESOLVE CLASS - 1 FAILURE TO PROVIDE SIDEWALK SHED WHERE REQUIRED.AT TIME OF INSPECTION AT AN ACTIVE ALTERATION CONSTRUCTION JOB SITE,I... $10,000 $0 Apr 8, 2021
Nov 12, 2019 35424375N RESOLVE CLASS - 1 BC3301.13.12=COMPETENT PERSONS AT TIME OF ALT 2 INSPECTION I OBSERVED ACTIEV JOBSITE OF 5 STY BUIDLING DOING INTERIOR... $2,500 $0 Mar 11, 2021
Feb 7, 2019 35385780H RESOLVE CLASS - 2 FAILURE TO POST OR PROPERLY POST PERMIT FOR WORK AT PREMISES.AT THE TIME OF MY INSPECTION OF AN ALTERATION 5 STORY BU... $0 $0 Apr 4, 2019
Mar 17, 2017 35218526Y ACTIVE CLASS - 2 FAILURE TO PROVIDE APPROVED/ACCEPTED PLANS, CONSTRUCTION DOCUMENTS AT JOBSITE, AT TIME OF INSPECTION. AT TIME OF INSP... $250 $0 Aug 18, 2017
Mar 17, 2017 35218525M ACTIVE CLASS - 1 FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTIONOPERATIONS. AT TIME OF INSPECTION I OBSERVED 5 ... $5,000 $0 Aug 17, 2017
Mar 25, 2015 34982567H ACTIVE CLASS - 2 28-104.7.7 FAILURE TO FILE TR1 FORM & DESIGNATE OPERATIONS SUBJECT TO CONTROLLED INSPECTION (SPECIAL INSPECTION)ON PL... $800 $0 May 14, 2015
May 14, 2008 38182291X ACTIVE Non-Hazardous 83X10. RETURN CAR TO SERVICE FOR PROPER INSP. $180 $0 Jul 10, 2008
Nov 3, 2006 38162099H ACTIVE Non-Hazardous 83X10: 83X10 REPAIR DEVICE BACK TO SERVICE(RESTORE) CALL THE DOB SO A COMPLETE INSPECTION CAN BE MADE BY THIS DEPT.12... $350 $0 May 17, 2007
Aug 23, 2005 34499507X RESOLVE Non-Hazardous ALTERED BLDG OCCUPIED W/O A VALID C OF O EXPIRED C OF O # 102630850T TO CREATE 7 NEW CLASS "A" DWELLING UNITS EXPIRED... $2,500 $0 Jan 19, 2006
Aug 23, 2005 34499506Y RESOLVE Non-Hazardous FAILURE TO PROVIDE FIRE STOPPING MATERIALS OF CONSTRUCTION GROUP I BLDGS (NON-COMBUSTIBLE) NOTE : AT 5TH FLOOR LEVEL ... $2,500 $0 Jan 19, 2006
May 31, 2001 34285360R RESOLVE Non-Hazardous WORK WITHOUT A PERMIT.NOTED:HAVING INSTALLED NEW FOOTINGS AND WALLS THROUGHOUT UNDER APPLICATION NO 102630850-01 REME... $0 $0 Mar 28, 2002
May 15, 2001 34284974R RESOLVE Non-Hazardous WORK WITHOUT A PERMIT.NOTED:BLDG DEMOED DOWN TO CRAKE 1OO PERCENT COMPLETE.NEW BLDG UNDER CONSTRUCTION.REMEDY:OBTAIN ... $0 $0 Jul 26, 2001
Jan 9, 2001 34267551K RESOLVE Hazardous FAILURE TO PROVIDE PROTECTION AT SIDES OF EXCAVATION. NOTED: THE EARTH APPROX 16'0" AT THE REAR WEST AND EARTH APPROX... $1,000 $0 May 17, 2001
Sep 1, 1994 38044032X RESOLVE Non-Hazardous 46T $0 $0 Nov 3, 1994
Jan 3, 1991 38004777Y RESOLVE Non-Hazardous 57O,30H,28J $75 $0 Mar 7, 1991