ECB violations
243-245 West 30 Street, Manhattan • Block 00780 • Lot 0015
37 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jun 17, 2024 | 37028758Z | ACTIVE | CLASS - 2 | A. C. 27-929.1, FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL SPRINK... | $6,250 | $6,250 | Dec 19, 2024 |
| Feb 28, 2023 | 37025333J | ACTIVE | CLASS - 2 | 27-929.1 FAILURE TO COMPLETE INSTALLATION OF FULL SYSTEM OF AUTOMATIC SPRINKLERS & FILE FINAL SPRINKLER REPORT PREPAR... | $10,000 | $10,000 | Jun 22, 2023 |
| Jan 24, 2023 | 35666378K | RESOLVE | CLASS - 2 | ILLEGAL USE IN A MANUFACTURING DISTRICT.UNLICENSED PHYSICAL TREAMENT ESTABLISHMENT,A PROHIBITED USE PER ZR12-10 OPERT... | $0 | $0 | Sep 12, 2024 |
| Oct 31, 2022 | 35665792L | ACTIVE | CLASS - 2 | ILLEGAL USE IN A MANUFACTURING DISTRICT. UNLICENSED PHYSICAL TREATMENTESTABLISHMENT IS OPERATING IN A M1-5 DISTRICT O... | $1,250 | $0 | Aug 28, 2023 |
| Nov 1, 2021 | 37022597J | ACTIVE | CLASS - 2 | SEC. AC 27-929.1 FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEMOF AUTOMATIC SPRINKLERS & FILE A FINAL SPRINKLE... | $6,250 | $70 | Nov 15, 2022 |
| Mar 30, 2021 | 37020950M | ACTIVE | CLASS - 2 | SEC. 27-929.1 FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OFAUTOMATIC SPRINKLERS & FILE A FINAL SPRINKLER R... | $10,000 | $10,000 | Jul 8, 2021 |
| Mar 30, 2020 | 37018880N | ACTIVE | CLASS - 2 | SEC. 27-929.1 AC 27-929.1 FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS & FILE A FINA... | $10,000 | $10,000 | Jul 2, 2020 |
| Nov 15, 2019 | 37016138J | ACTIVE | CLASS - 2 | 27-929.1 A.C. 27-929.1,FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS AND FILE A FINAL... | $6,250 | $6,250 | Feb 13, 2020 |
| Oct 15, 2018 | 37013614H | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT A REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPUR... | $1,250 | $0 | Jul 11, 2019 |
| Jan 30, 2016 | 38239936Z | ACTIVE | CLASS - 2 | 57-L-11,59-M-15,11-M-07,01-L-10,70-O-02:57-L-11-FIRE EXTINGUISHER IN (MOTOR) RM NEEDS RECHARGING & EXPIRED OVER 10 YE... | $2,500 | $0 | Mar 17, 2016 |
| Sep 2, 2015 | 38238516H | ACTIVE | CLASS - 1 | 100M07,70O02,68B07,30M07. 100M07-NO FIREMAN SERVICE AS PER APPENDIX K CHAPTER 3 ALL ELEVATORS SHALL HAVE FIREMAN SERV... | $5,000 | $0 | Oct 22, 2015 |
| Sep 2, 2015 | 38238515X | ACTIVE | CLASS - 1 | 100M07,40B07,68B07,01L10,02AA07,03D06,30M07,70O02. 100M7-NO FIREMAN SVC.AS PER APPENDIX K CHAPTER 3 ALL () SHALL HAVE... | $5,000 | $0 | Oct 22, 2015 |
| Aug 18, 2011 | 34923826N | RESOLVE | CLASS - 1 | BC1005.2)FAILURE TO COMPLY E/ DOOR ENCROACHMENT.NOTED:EXIT DOOR @ 1 FLR FROM SPA REDUCING REQUIRED W/ FOR MORE THAN 7... | $1,600 | $0 | Oct 6, 2011 |
| Aug 18, 2011 | 34923825L | ACTIVE | CLASS - 2 | ALTERED/CHANGED BLDG OCCUPIED W/O VALID CERT OF OCCUPANCY AS PER 28-118.3.1 -28-118.3.2.REM:OBTAIN VALID CERT OF OCCU... | $500 | $0 | Oct 6, 2011 |
| Aug 18, 2011 | 34923824J | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY.NOTED:@ CELLAR LEVEL EXIT PASSAGEWAY(SOUTH)OBSTRUCTED BY FURNITURE & ... | $1,200 | $0 | Oct 6, 2011 |
| Jul 19, 2010 | 34851698H | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER DEFECTS NOTED 7FL ROOM 701 702 703 DROOP CEILING NOT ERECTED TO COD... | $2,500 | $0 | Sep 9, 2010 |
| Jul 19, 2010 | 34851697X | RESOLVE | CLASS - 2 | WORK W/O A PERMIT WORK NOTED 7TH FL ROOM 701 702 703 ERECTED DROP CEILING W/ LIGHTING FIXTURES STOP ALL WORK REM: OBT... | $0 | $0 | Mar 17, 2011 |
| Feb 11, 2010 | 38209011J | RESOLVE | CLASS - 2 | 45M11.53Q3.40I10.16P16.45M11 MISSING COTTER PINS AT ADJUSTMENT LINEAGEREPLACE COTTER PINS 53Q3 REPLACE MISSING GOV. R... | $250 | $0 | Apr 8, 2010 |
| Feb 11, 2010 | 38209012L | RESOLVE | CLASS - 2 | 62AA2.41B1.62AA02 OBSERVED DURING MOTION COMMUTATOR SPARKS PROPERLY CLEAN CARBON BLDG OFF COMMUTATOR ADJUST DOOR TO S... | $250 | $0 | Apr 8, 2010 |
| Dec 17, 2009 | 38207943K | RESOLVE | CLASS - 1 | CEASE USE ITEMS 59 BRAKE LININGS MISSING.07 SAFETY EDGE INOPER.02 ALARM BELL INOPERATIVE CALL 2125665542 TO RESTORE T... | $5,000 | $0 | Feb 11, 2010 |
| Jan 29, 2008 | 38179119R | RESOLVE | Non-Hazardous | 16D10,86BB05,40T07,40D06. 16D-PROPERTY SECURE AND PROVIDE DEAD BOLTS FOR SWING DOORS BAS, LOBBY 9,11,12TH FLOORS ALSO... | $800 | $0 | Mar 20, 2008 |
| Oct 4, 2006 | 34550876M | RESOLVE | Non-Hazardous | FAILURE TO AN AMENDED 5TH ROUND REPORT ACCEPTABLE TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED I... | $10,000 | $0 | Dec 14, 2006 |
| May 19, 2006 | 34549917L | RESOLVE | Non-Hazardous | FAILURE TO FILE AN AMENDED 5TH ROUND REPORT ACCEPTABLE TO THIS DEPARTMENT INDICATING CORRECTION OF UNSAFE CONDITIONS ... | $10,000 | $0 | Sep 28, 2006 |
| Mar 14, 2006 | 34549560H | RESOLVE | Non-Hazardous | FAILURE TO FILE AN AMENDED FIFTH ROUND REPORT ACCEPTABLE TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESC... | $10,000 | $0 | May 25, 2006 |
| Nov 28, 2005 | 34548828P | RESOLVE | Non-Hazardous | FAILURE TO FILE AN AMENDED FIFTH ROUND REPORT ACCEPTABLE TO THIS DEPARTMENT INDICATING CORRECTION OF UNSAFE CONDITION... | $10,000 | $0 | Feb 2, 2006 |
| Oct 26, 2005 | 34499580M | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN. DEFECT IS: PAINT ON 12TH FLOOR CEILING CHIPPING IN VARIOUS LOCATIONS DUE TO WATER LEAK FROM THE ... | $2,500 | $0 | Dec 15, 2005 |
| Sep 13, 2005 | 38155055K | RESOLVE | Non-Hazardous | 41H11/55O02/55Y13/58E01/17M07/19B01 (41) WORN CONTACTS ON "P" AND "A1"RELAY (55) OIL LEAK ON MACHINE CLEAN AND SEAL (... | $0 | $0 | Nov 3, 2005 |
| Feb 11, 2005 | 34461186K | RESOLVE | Non-Hazardous | FAILURE TO FILE AN AMENDED FIFTH ROUND REPORT ACCEPTABLE TO THIS DEPT.INDICATING CORRECTION OF UNSAFE CONDITIONS DESC... | $2,500 | $0 | Dec 1, 2005 |
| Aug 20, 2004 | 34461910M | RESOLVE | Non-Hazardous | FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT: PERIODIC INSP OF EXTERIOR WALLS & APPURTENANCES AS REQUIRED BY LOCA... | $1,750 | $0 | Feb 24, 2005 |
| Mar 15, 2004 | 34408402N | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN EXTERIOR BLDG.FACADE ISSUES(1)SOUTH ELEVATION,WESTEND BULGING IN THE FACADE OPEN MORTAR JOINTS CO... | $800 | $0 | May 6, 2004 |
| Jan 9, 2004 | 34462810J | RESOLVE | Non-Hazardous | FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT PERIODIC INSPECTION OR EXTERIOR WALLS AND APPURTENANCES AS REQUIRED ... | $0 | $0 | May 6, 2004 |
| Aug 26, 2002 | 38125281L | RESOLVE | Non-Hazardous | 46#12/ 10I11/ 21X11/ 15I11/ 22D06/ 15L11/ 15D07/ 18B11/ 03B11/46 - REPLACE WORN DEFECTIVE HOISTWAY ROPES 10 - REPAIR ... | $0 | $0 | Oct 10, 2002 |
| Mar 28, 2001 | 38115447N | RESOLVE | Non-Hazardous | 73X07.73 RETURN DEVICE TO SERVICE TO A COMPLLETE SAFETY INOPECTION CAN BE PERFORMED. | $0 | $0 | May 17, 2001 |
| Jul 12, 1999 | 38088801X | RESOLVE | Non-Hazardous | 74L 15H 74 L 11 FAN FOR VENTING IS NOT WORKING 15 H 12 REPLACE G BS ON HOISTWAY DOOR 1ST FLOOR | $0 | $0 | Aug 27, 1999 |
| Sep 1, 1998 | 38079252H | RESOLVE | Non-Hazardous | 50Y14 42H11 46B15 57O02 73U16 50 PROPERLY SEAL MANCHINE 42 REPAIR MANCHINE BRAKE DRUM. 46 SHORTEN HOIST ROPES. 57-CLE... | $0 | $0 | Oct 22, 1998 |
| Sep 1, 1998 | 38079253J | RESOLVE | Non-Hazardous | 50F09 05I12 64B15 73U16 50 REMOVE LOST MOTION FROM MACHINE. 05 REPAIR CAR GATE. 64 PROPERLY POSITION COMP CHAIN. 73 I... | $0 | $0 | Oct 22, 1998 |
| Nov 3, 1997 | 38065160N | RESOLVE | Non-Hazardous | 54I 54-MAIN LINES SWITCH BROKEN. | $0 | $0 | Jan 15, 1998 |