ECB violations
Madison Square Garden, Manhattan • Block 00781 • Lot 0001
388 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jul 13, 2011 | 34898121L | RESOLVE | CLASS - 1 | 3314.9.2 SUPPORTED SCAFFOLD DOES NOT MEET CODE SPECIFICATIONS NOTE SUPPORTED SCAFFOLDS OF VARIOUS HEIGHT 1, 2, 3, & 4... | $1,600 | $0 | Sep 1, 2011 |
| Jul 13, 2011 | 34922305N | RESOLVE | CLASS - 1 | UPON INSP AS NOTED ON ACTIVE CONSTRUCTION SITE OBSERVED MASON WORKING ON A METAL FRAMED BAKER SCAFFOLD THERE WERE MAN... | $2,400 | $0 | Sep 1, 2011 |
| Jul 13, 2011 | 34922306P | RESOLVE | CLASS - 2 | UPON INSP AS NOTED ON ACTIVE CONTRUCTION SITE OBSERVED SMOKING REFUSE CIGARETTE BUTTS 8FL & 7FL LOADING PLATFORMS APP... | $1,200 | $0 | Sep 1, 2011 |
| Jul 7, 2011 | 34911376R | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS CONSTRUCTION MATERIAL & DEBRIS NOT PROPERLY STORED... | $0 | $0 | Dec 8, 2011 |
| Jul 6, 2011 | 34911272M | RESOLVE | CLASS - 2 | OBSERVED RECENT SMOKING REFUGE W/ CONSTRUCTION/DEMO SITE IN VIOLATION OF NYC FIRE CODE.@ TIME OF INSPEC I DID OBSERVE... | $400 | $0 | Nov 3, 2011 |
| Jul 6, 2011 | 34911274X | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE LOCATION &/OR USE OF HOSE LINES,WIRES,ROPES,PIPES,CHAINS,& CONDUITS THAT CROSS WALKWAYS SO AS TO N... | $1,600 | $0 | Nov 17, 2011 |
| Jul 6, 2011 | 34911273Y | RESOLVE | CLASS - 3 | BC3301.2)FAILURE TO PROVIDE 3'6" GUARD RAILS ON EQUIVALENT AROUND ALL FLR & PERIMETER FLR OPENINGS.@ TIME OF INSPEC I... | $0 | $0 | Aug 25, 2011 |
| Jun 29, 2011 | 34898116R | RESOLVE | CLASS - 1 | FAILURE TO PERFORM SAFE/PROPER INSPECTION OF SUSPENDED SCAFFOLD/PLATFORM. NOTE: NO RECORD OF DAILY INSPECTION OF INTE... | $1,600 | $0 | Jan 5, 2012 |
| Jun 29, 2011 | 34911090L | RESOLVE | CLASS - 2 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. UPON INSPECTION EXCESSIVE SERVICE CO... | $600 | $0 | Oct 27, 2011 |
| Jun 29, 2011 | 34909167H | RESOLVE | CLASS - 2 | SEC. 3301.2. FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION: HOLES IN FLR UPON INS... | $0 | $0 | Aug 18, 2011 |
| Jun 29, 2011 | 34911089Y | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. UPON INSPECTION CONTRACTOR HAS FAILE... | $2,400 | $0 | Oct 27, 2011 |
| Jun 29, 2011 | 34909169L | RESOLVE | CLASS - 2 | SMOKING AT CONSTRUCTION/DEMOLITION SITE. UPON INSPECTION AS NOTED ON ACTIVE CONSTRUCTION SITE OBSERVED SMOKING REFUSE... | $600 | $0 | Oct 27, 2011 |
| Jun 29, 2011 | 34909168J | RESOLVE | CLASS - 1 | SEC. 3301.7. FAILURE TO PROVIDE DESIGN DRAWING: UPON INSPECTION AS NOTED ON ACTIVE CONSTRUCTION SITE THERE ARE TEMPOR... | $1,600 | $0 | Oct 27, 2011 |
| Jun 29, 2011 | 34911088M | RESOLVE | CLASS - 1 | SEC. 3301.2 FAILURE TO PROVIDE 3FT 6 INCH GUARDRAIL OR EQUIVALENT AROUND ALL FLOOR & PERIMETER OPENINGS. UPON INSPECT... | $1,600 | $0 | Oct 27, 2011 |
| Jun 22, 2011 | 34911068P | RESOLVE | CLASS - 1 | SEC. 3301.2 FAILURE TO PROVIDE 3FT 6INCH GUARDRAILS OR EQUIVALENT AROUND ALL FLOOR & PERIMETER OPENINGS. UPON INSPECT... | $1,600 | $0 | Oct 25, 2011 |
| Jun 22, 2011 | 34911072H | RESOLVE | CLASS - 2 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS UPON INSPECTION OBSERVED MANY SERVICE... | $400 | $0 | Oct 13, 2011 |
| Jun 22, 2011 | 34911071X | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS UPON INSPECTION AT 7TH FLOOR BETWEEN ... | $2,400 | $0 | Oct 25, 2011 |
| Jun 22, 2011 | 34911070Y | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. UPON INSPECTION CONTRACTOR FAILED TO... | $2,400 | $0 | Oct 25, 2011 |
| Jun 22, 2011 | 34911069R | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS AFFECTED BY CONSTRUCTION OPERATIONS. UPON INSPECTION CONTRACTOR FAILED TO PROVIDE RE... | $2,400 | $0 | Oct 25, 2011 |
| Jun 22, 2011 | 34858104N | RESOLVE | CLASS - 1 | SEC. 3314.4.2 SUPPORTED SCAFFOLDS USED FOR BRICK LAYING AT FLOORS 9,6,5 & STEEL ERECTION. DOES NOT MEET CODE SPECIF. ... | $1,600 | $0 | Oct 20, 2011 |
| Jun 22, 2011 | 34858103L | RESOLVE | CLASS - 1 | SEC. 3314.4.3 NO RECORD OF DAILY INSPECTION OF SUPPORTED SCAFFOLDS UNDER PERMITS #120616985,#120626297,#120635358 SSM... | $1,600 | $0 | Oct 20, 2011 |
| Jun 22, 2011 | 34858102J | RESOLVE | CLASS - 1 | NO RECORD OF DAILY INSPECTION OF SUSPENDED SCAFFOLD UNDER PERMIT 120658653. PERFORMED BY AUTHORIZED PERSON AT SITE OB... | $2,400 | $0 | Oct 20, 2011 |
| Jun 22, 2011 | 34909165Y | RESOLVE | CLASS - 2 | SEC. 3307.4.1 VEHICULAR TRAFFIC (NO WARNING LIGHTS). AS NOTED ON ACTIVE ALTERATION SITE THERE WERE NO WARNING LIGHTS/... | $0 | $0 | Aug 11, 2011 |
| Jun 16, 2011 | 34903846M | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS, IN THAT ELECTRICAL WORKER RECEIVED 1... | $0 | $0 | Dec 1, 2011 |
| Jun 15, 2011 | 34911186X | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS AFFECTED BY CONSTRUCTION OPERATIONS.UPON INSPECTION @ LEVEL 9 COLUMN 47 CONTRACTOR L... | $2,400 | $0 | Jan 11, 2012 |
| Jun 15, 2011 | 34911185Y | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS UPON INSP @ LEVEL 7 BETWEEN 9 & 10 WO... | $2,400 | $0 | Aug 4, 2011 |
| Jun 1, 2011 | 34911075N | RESOLVE | CLASS - 2 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONST OPERATIONS.STANDPIPE @ STAIRWELL.1 CONTRACTOR HAS FAILE... | $400 | $0 | Jul 21, 2011 |
| Jun 1, 2011 | 34911076P | RESOLVE | CLASS - 2 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONST OPERATIONS.UPON INSP SERVICE LINES & WIRES CONSTITUTE A... | $400 | $0 | Jul 25, 2011 |
| May 25, 2011 | 34890458K | RESOLVE | CLASS - 2 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS AT TIME OF INSPECTION I DID OBSERVE A... | $0 | $0 | Oct 6, 2011 |
| May 25, 2011 | 34890457Z | RESOLVE | CLASS - 2 | SEC. 27-1009A BC 3301.2 FAILURE TO PROVIDE 3'FT 6" INCH GUARDRAILS OR EQUIVALENT AROUND ALL FLOOR & PERIMETER OPENING... | $0 | $0 | Jul 28, 2011 |
| May 18, 2011 | 34906683K | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE STAND PIPE IN READINESS: UPON INSPECTION AS NOTED ON ACTIVE CONSTRUCTION SITE THE NEW STANDPIPES T... | $0 | $0 | Sep 15, 2011 |
| May 18, 2011 | 34910939R | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS UPON INSPECTION NUMEROUS HOLES IN FLR... | $0 | $0 | Sep 15, 2011 |
| May 18, 2011 | 34910940Y | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS &/OR APPROVED AMENDMENTS.UPON INSPECTION CONTRACTOR HAS BUIL... | $0 | $0 | Jul 7, 2011 |
| May 18, 2011 | 34906685Y | RESOLVE | CLASS - 2 | SEC. 3301.10 OBSCURES LAWFUL SIGNS. UPON INSPECTION AS NOTED ON ACTIVECONSTRUCTION SITE THE PARAPET BOARDING ON TOP O... | $0 | $0 | Jul 7, 2011 |
| May 18, 2011 | 34910938P | RESOLVE | CLASS - 2 | FAILURE TO POST NO SMOKING SIGNS @ CONSTRUCTION/DEMO SITE IN VIOLATION OF NYC FIRE CODE.@ TIME OF INSPEC NO SMOKING S... | $0 | $0 | Jul 7, 2011 |
| May 18, 2011 | 34910941X | RESOLVE | CLASS - 2 | FAILURE TO SAFE GUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS.UPON INSPECTION OBSERVED LOOSE CONST... | $0 | $0 | Sep 15, 2011 |
| May 18, 2011 | 34910937N | RESOLVE | CLASS - 2 | OBSERVED RECENT SMOKING REFUSE WITHIN CONSTRUCTION/DEMO SITE IN VIO OF NYC FIRE CODE.UPON INSPECTION SMOKING REFUSE W... | $0 | $0 | Sep 15, 2011 |
| May 11, 2011 | 34911052K | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONST OPERATIONS.UPON INSP @ 5TH FLOOR MOBILE ELECTRIC SUBPAN... | $1,600 | $0 | Jul 27, 2011 |
| May 11, 2011 | 34910927J | RESOLVE | CLASS - 1 | 3301.2 FAILURE TO PROVIDE 3'6" GUARD RAILS OR EQUIVALENT AROUND ALL FL& PERIMETER OPENINGS.UPON INSP CONTRACTOR FAILE... | $0 | $0 | Jun 30, 2011 |
| May 11, 2011 | 34910929N | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONST OPERATIONS.UPON INSP @ 5TH FL MONILE ELECTRIC SUB PANEL... | $0 | $0 | Jun 30, 2011 |
| May 11, 2011 | 34911050R | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONST OPERATIONS.UPON INSP MANY HOLES IN FLOOR OF THE 6TH FLO... | $1,600 | $0 | Jul 25, 2011 |
| May 11, 2011 | 34911051Z | RESOLVE | CLASS - 1 | SEC. 3301.2 FAILURE TO PROVIDE 3FT 6 INCH GUARDRAILS OR EQUIVALENT AROUND ALL FLOOR & PERIMETER OPENINGS. UPON INSPEC... | $1,600 | $0 | Jul 27, 2011 |
| Apr 18, 2011 | 34910654N | RESOLVE | CLASS - 1 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS &/OR APPROVED AMENDMENTS. UPON INSPECTION PLANS FAILED TO PR... | $0 | $0 | Jun 24, 2011 |
| Apr 18, 2011 | 34910653L | RESOLVE | CLASS - 1 | FAIL TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS UPON INSPECTION CONTRACTOR WAS HOISTING ... | $2,400 | $0 | Sep 22, 2011 |
| Apr 13, 2011 | 34741919P | RESOLVE | CLASS - 2 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS NOTED UPON INSPECTION CONTRACTOR HAS ... | $800 | $0 | Aug 4, 2011 |
| Feb 16, 2011 | 34890320H | RESOLVE | CLASS - 1 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS NOTED UPON INSPECTION. CONSTRUCTI... | $1,000 | $0 | Apr 7, 2011 |
| Feb 16, 2011 | 34890319K | RESOLVE | CLASS - 1 | SEC. 3301.2 VIOLATIONS FAILURE TO PROVIDE 3FT 6 INCH GUARDRAILS OR EQUIVALENT AROUND ALL FLOOR & PERIMETER OPENINGS. ... | $0 | $0 | Apr 7, 2011 |
| Feb 16, 2011 | 34890321J | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSON & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS NOTED UPON INSPECTION AT 5TH FL ROOF A... | $2,400 | $0 | Apr 7, 2011 |
| Dec 1, 2010 | 34867286H | RESOLVE | CLASS - 2 | SEC 3301.2 MISC VIOL: FAIL TO PROVIDE 3' 6" GUARD RAILS OR TOE BOARDS AROUND ALL FLOOR & PERIMETER OPENINGS. NOTED: U... | $0 | $0 | Jan 20, 2011 |
| Dec 1, 2010 | 34867287J | RESOLVE | CLASS - 2 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTIONOPERATIONS. UPON INSPECTION ZERO CABLE ON 7 & 8... | $1,200 | $0 | Jan 20, 2011 |